Figure 3.7 - Main Status Indicators For Multi-Amplifier Systems - AE Techron 7224 Operator's Manual

Single-channel industrial amplifier for demanding, high-power systems
Hide thumbs Also See for 7224:
Table of Contents

Advertisement

3.2.3 Main Status Indicators for
Multi-amplifier Systems
The Main Status indicators on each amplifier in 
a multi-amp system are used to determine the
Figure 3.7 – Main Status Indicators for Multi-Amplifier Systems
Indicator is lit
Main Status
of One or
More Amps in
the System
Run
Ready
Standby
Stop
Run
Ready
Standby
Stop
Run
Ready
Standby
Stop
Run
Ready
Standby
Stop
14
Indicator is not lit
Main Status of
Other Amps in
the System
State of Operation
Run mode:  All of the amplifiers in the 
Run
system are in Run mode. The amplifiers' 
Ready
high-voltage transformers are energized 
Standby
and the system will amplify the input
Stop
signal.
Remote Standby Condition: All of
the amplifiers in the system are being 
held in Standby mode by an external
Run
condition. In Standby mode, the ampli-
Ready
fiers' low-voltage transformers are ener-
gized but the high-voltage transformers 
Standby
are not.
Stop
System Not Ready: If one or more
of the amplifiers has no LEDs lit, the 
Run
amplifier has no power or has not been 
Ready
turned on, and the other amplifiers in the 
system will be held in Standby mode.
Standby
In Standby mode, the amplifier's low-
Stop
voltage transformer is energized but the 
high-voltage transformers are not.
Stop mode: When the Stop button on
any amplifier in the system is pressed, 
that amplifier will enter Stop mode and 
all other amplifiers will enter Standby 
Run
mode. The system may also enter Stop
Ready
mode after powering up if one or more
Standby
amplifiers in the system is configured 
Stop
to enter Stop mode on startup. In Stop
mode, the amplifier's low-voltage trans-
former is energized but the high-voltage 
transformers are not.
Information subject to change
7224 OPERATOR'S MANUAL – SECTION 3
operational status of the amplifier. When evaluated 
along with the statuses of other amplifiers in the 
system, the Main Status indicators can be used to 
determine the system status and the action re-
quired to return the system to Run mode.
Indicator may be lit
Action Needed to Return to
Run Mode
N/A
If the amplifiers remain in Standby 
mode, the system is being held in
Standby by remote control through the
SIM Interlock I/O connector. Open the 
Enable/Standby switch to clear this 
remote Standby condition and return
the system to Run mode. See the
"Applications" section of this manual
for more information on remote ampli-
fier operation.
Make sure all amplifiers have AC 
power and have been turned on. When
all amplifiers attain Standby status, all 
amplifiers in the system will simultane-
ously be placed in Run mode.
To release the system from Stop mode,
press the Enable button on the ampli-
fier displaying the Stop mode status.
97-7224006_3-31-15