6.0
Installation - Page 29
Fitting the Combustion Box Assembly
CAUTION: Care must be taken when lifting the boiler on
backplate. Get assistance if required.
1. Remove the sealing tape from the taps.
and locate the slots on the back plate on to the hooks on the
wall plate (Fig 70 & 71).
to damage the boiler pipework and fittings.
4. Engage the two retaining latches and secure the right
5. Take the three washers from the kit and insert them
between the water flow and return pipes, pressure relief
relief washer is the smaller of the three.
6. Tighten all the nuts to the taps.
7. Undo the four screws securing the transit bracket to the
combustion box door and chassis. Remove the bracket and
discard.