Baxi 35/60 User Operating Instructions Manual

Baxi 35/60 User Operating Instructions Manual

Gas fired wall mounted system boilers

Advertisement

Baxi System 35/60 & 60/100
Gas Fired Wall Mounted System Boilers
User's Operating
Instructions
Please keep these instructions safe.
Should you move house, please hand
them over to the next occupier.

Advertisement

Table of Contents
loading

Summary of Contents for Baxi 35/60

  • Page 1 Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Baxi System 35/60 & 60/100 Gas Fired Wall Mounted System Boilers User’s Operating Instructions...
  • Page 2: Natural Gas

    Notified Body 0051. mean continued success. Product/Production certified by: Notified Body 0051. We hope you get a satisfactory service from Baxi. If not, please let us know. For GB/IE only. Baxi is a BS-EN ISO 9001 Accredited Company...
  • Page 3: This Appliance Must Be Earthed

    If a water or gas leak occurs or is suspected, the boiler can be appliance without the express written isolated at the inlet valves as follows; permission of Baxi UK Limited could invalidate 1. Turn off the electrical supply and turn the selector switch on the appliance warranty and infringe the G the facia box to the OFF position.
  • Page 4 2.0 Introduction Introduction 1. Your Baxi System 35/60 or 60/100 is a gas fired, room sealed, powered flue boiler, providing central heating and hot water for your home. It is fully automatic and does not have a pilot light. Facia Panel 1.
  • Page 5: Operating The Boiler

    3.0 Operating the Boiler Operating the Boiler 1. Ensure that the electricity and gas supplies are turned on. Check that the central heating pressure is between 0.2 and 1.0 bar (Fig. 4). 2. Turn the On/Off/Reset selector switch either anti-clockwise from the off position (Fig. 6) to both central heating and hot water or clockwise to domestic hot water only.
  • Page 6 3.0 Operating the Boiler Temperature Control 1. The central heating water flow temperature can be adjusted between 30° C (± 5° C) minimum and 85° C (± 5° C) maximum. 2. Turn the control knob clockwise to increase the temperature (Fig. 9). 3.
  • Page 7: Pump Fault/Low Pressure

    1 minute in every 24 hours to prevent sticking. Safety Thermostat 1. Your Baxi System 35/60 or 60/100 is fitted with an additional safety device, which shuts down the boiler in the event of the system or the boiler overheating.
  • Page 8: Central Heating System Pressure

    3.0 Operating the Boiler Pressure Gauge Central Heating System Pressure 1. The water pressure in the central heating system is indicated by the pressure gauge. 2. With the system cold and the boiler not Fig. 14 operating the pressure should be between 0.2 Normal Pressure (when cold) and 1.0 bar.
  • Page 9: Clearances Around Boiler

    4.0 Clearances and Check List 5mm Min 450mm 5mm Min Clearances around the Boiler (Figs. 19 & 20) 1. The minimum clear spaces needed around 200mm Min the boiler measured from the casing are as follows: 200mm Bottom 200mm Both sides - Front (In Operation) 450mm...
  • Page 10 (Fig. 20). Fig. 20 Guarantee 1. Your Baxi System 35/60 or 60/100 is designed and produced to meet all the relevant Standards. Information Label 2. Baxi UK Limited provide a 12 month guarantee on the boiler.
  • Page 11 Baxi UK Limited manufacture a comprehensive range of products for the domestic heating market. Gas Central Heating Boilers (Wall, Floor and Fireside models). Independent Gas Fires. Renewal Firefronts. Gas Wall Heaters. Solid Fuel Fires. If you require information on any of these products,...
  • Page 12: After Sales Service

    Comp N 248545 - Iss 2 - 9/01 After Sales Service 08706 096 096 Baxi UK Limited Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN www.baxi.com 921.765.1...