Baxi Solo 3 30 PF System Installation And Servicing Instructions page 23

Wall mounted powered flue system boiler gas fired central heating unit
Table of Contents

Advertisement

6.0
Installation - Page 23
6.10 Method A (Cont)
7. Engage the assembly into the hole previously cut in the
wall and slide into place (Fig. 50).
8. Secure the assembly to the wall at the previously drilled
anchorage points with suitable screws. Before finally
tightening the screws, check that the assembly is level.
9. Make good between the wall and the air duct inside and
outside the building if the internal fitting kit has not been
used (Fig. 51).
10. The flue trim provided may be fitted if required, to neaten
up the make-up around the terminal (Fig. 52).
11. To fit the flue terminal trim:
a) The trim should be fitted once the flue is secure.
b) Take the three edge clips from the kit and fit to equi-
spaced onto the inner flange of the trim (Fig. 51a).
c) With the flanges towards the wall pass the trim over the
terminal. If required a bead of sealant may be applied to the
rear face of the trim.
d) Push firmly on the trim to ensure the edge clips engage
on the flue.

Hide quick links: