6.0
Installation - Page 16
6.3 Fan Outlet Restrictor
5
Rear Flue only up to 500mm (19
/
In)
8
1. Release the four latches holding the combustion box door
(Fig 16). Remove the combustion box door by pulling
forward (Fig. 16).
2. Release the 5-pin electrical plug connecting the pressure
switch and fan (Fig. 15). Withdraw the fan assembly by
pulling forwards from the top edge (Fig. 16).
3. Take the restrictor (supplied in the kit of pads), check that
the number stamped on the restrictor matches the appliance
(e.g. 50 stamped on the restrictor is for 50 PF appliance)
4. Fit the restrictor to the fan outlet flange, bending the 3
lugs equally over the flange to secure (Fig. 17).
5. Re-assemble the fan assembly and combustion box door.