HOT AND COLD WATER CONNECTION
Connect the appliance to quality hot and cold
water via a pressure hose with 3/4" couplings.
A shut off valve is to be provided adjacent to the
unit.
1/2" Appliance Hose
With 3/4" Hose Fittings
NOTE: Operating the steamer without the
water regulator installed will invali
date your warranty.
Water must meet the following minimum re
quirements:
Total Dissolved Solids (TDS) content will
D
not exceed 30 parts per million.
Water PH must be 7.0 or higher
D
NOTE: The use of poor quality water will in
validate your warranty.
Regulator

Installation and Connection

DRAIN CONNECTION
The Drain Vent assembly, included with the unit,
and a 2I pipe with standard drain pitch, should
be run to an open drain or connected to a stand
pipe equipped with a vent. The waste water can
also be directed to a nearby floor drain.
Please use the drain vent assembly and a 2"
pipe for drain connection. Flexible hose
which allows trapped water to accumulate in
sagged runs must be avoided.
To Drain
A 24" long standpipe must be connected to the
DWV. This allows the escaping water vapor to
exit above the inlet louvers on the back panel.
Breather Vent
Plumber Installed
Connection
Tee, Hose
and Clamps
Plumber Installed
Connection To Drain
7
Installation
Steamer
Drain
2" Drain
Customer
Supplied