Fault Code Problem Solving Charts
The following charts can be used as a guide to help locate faults in a
DishDrawer. Answer each question with a yes or no and follow the
instructions inside the relevant box.
F1 The flood switch has been activated for more than 6 seconds
Question
1
Is there a F1 on both
displays?
2
Has a flood occurred?
(N.B. The flood may
have dried up)
3
Is the lid sealing on the
tub correctly?
4
Are the lid actuators
functioning correctly?
5
Is the water level in the
tub high?
6
Is the water inlet valve
leaking?
7
Is the DishDrawer
priming correctly?
8
Is the spray arm split?
Yes
Go to Question 2
Go to Question 3
Go to Question 5
Go to Question 5
Go to Question 6
Replace inlet
valve
Go to Question
12
Replace spray
arm
20
No
If power fails to the
bottom tub it will cause
the top tub to go F1.
Test heater plate.
Go to Question 13
Go to Question 4
Check the lid actuators
are assembled correctly
on the slides and yokes.
Check the plugs on the
RFI board and the
terminals on the lid
motors. If the lid
actuators look slow
replace them.
Go to Question 8
Go to Question 7
Go to Question 8
Go to Question 9