Cleaning And Maintenance - Terbly Beam 2R User Manual

Led moving head
Table of Contents

Advertisement

malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The color wheel is not located in the default position after the reset.
02Er
(Fixed gobos error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The Fixed gobos is not located in the default position after the reset.
05Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke's
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective
(or its driving IC on the main PCB). The PAN- movement is not located in the default position after the
reset.
06Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is
defective (or its driving IC on the main PCB). The TILT- movement is not located in the default position
after the reset.

11. CLEANING AND MAINTENANCE

The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and
must not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation
spots (ceiling, suspension, trussing).
3) Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
4) The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed.
In order to make the lights in good condition and extend the life time, we suggest a regular
cleaning to the lights.
1) Clean the inside and outside lens each week to avoid the weakness of the lights due to
accumulation of dust.
2) Clean the fan each week.
3) To make sure the smooth gobo rotation, we suggest adding proper lube to the wheel each
three month, avoiding the excessive lube splashes during the gobo rotating.
4) A detailed electric check by approved electrical engineer each three month, make sure that
the circuit contacts are in good condition, prevent the poor contact of circuit from
overheating.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use
- 31 -