Do not shake the device.Avoid brute force when installing or operating the device.
While choosing the installation-spot, please make sure that the device is not exposed to extreme
heat, moisture or dust. Please don't project the beam onto combustible substances.The minimum
distance between light-output from the projector and the illuminated surface must be more than 5
meter.
If you use the quick lock cam in hanging up the fixture, please make sure the quick lock fasteners
turned in the quick lock holes correctly.
Operate the device only after having familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional
operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden.
If this device will be operated in any way different to the one described in this manual, the
product may suffer damages and the guarantee becomes void. Furthermore, any other operation
may lead to short-circuit, burns, electric shock, lamp explosion, crash, etc.

4. INSTALLATION INSTRUCTIONS

4.1) Installing or replacing the lamp

Onl y install the lamp with the device unplugged from the mains.
The lamp has to be replaced when it is damaged or deformed.
Because of the nature of the extreme heat associated with the Platinum 2R lamp and
the tight nature of the internal optical system it is imperative that the lamp be
replaced every 6000 hours. This is done to protect the internal optical system as well
as prevent accidental lamp explosion, which could lead to hot glass particles falling
from the fixture. Failure to change the lamp within 300 hours of operation will result
in automatic shut down of the fixture's electronics.
At 6000 hours the display will begin to flash "Replace The Lamp" and the lamp will
flicker for the first five minutes of operation. At this point the lamp has reached the
maximum rated life and should be replaced immediately.After the lamp has flickered
for about five minutes it should strike normally allowing the fixture to be used
temporarily until a replacement lamp can be installed. The fixture will continue to
operate for an additional 300 hours, however the "Replace the Lamp" warning will
continue to flash in the display. Keep in mind that the flicker protection circuitry will
only work for about 300 hours (lamp clock life of 6000-6300 hours). After 6300
hours the fixture will no longer respond to DMX commands and immediately enter
- 4 -
XM974-V1.0-NR

Hide quick links: