Lexmark T650n Service Manual page 55

Hide thumbs Also See for T650n:
Table of Contents

Advertisement

Error
code or
Error contents
message
202.30
Never sent the divert
command to the
stacker.
Type 2 fuser
202.31
Sensor (fuser output)
static jam
Type 2 fuser
202.32
Sensor (fuser output)
lingering jam.
Type 2 fuser
202.34
Sensor (fuser output)
lingering jam.
Type 2 fuser
202.35
Sensor (fuser output)
lingering jam.
Destination is output
option.
Type 2 fuser
202.36
Sensor (fuser output)
lingering jam.
Destination is
standard bin.
Type 2 fuser
202.37
Sensor (fuser output)
lingering jam.
Destination is output
option.
Type 2 fuser
202.38
Sensor (fuser output)
static jam
and
Sensor (narrow
media) static jam
Type 2 fuser
Description/Action
Media remains on the sensor
(fuser output) during the warm
up sequence.
Media reached the sensor
(fuser output) but did not clear
it in the specified time.
Media reached the sensor
(fuser output) but did not clear
it in the specified time.
Media reached the sensor
(fuser output) but did not clear
it in the specified time.
and
Media did not reach the sensor
(narrow media)
Media reached the sensor
(fuser output) but did not clear
it in the specified time.
and
Media did reach the sensor
(narrow media)
Media reached the sensor
(fuser output) but did not clear
it in the specified time.
and
Media did reach the sensor
(narrow media)
Media remains on the sensor
(fuser output) and the sensor
(narrow media) during the
warm up sequence.
Possible repair actions
Go to sensor (fuser output)
static jam service check.
See
"Sensor (fuser output)
static jam service check" on
page
2-128.
Go to sensor (fuser output)
lingering jam service check.
See
"Sensor (fuser output)
lingering jam service check."
on page
2-127.
Go to sensor (fuser output)
lingering jam service check.
See
"Sensor (fuser output)
lingering jam service check."
on page
2-127.
Go to sensor (fuser output)
lingering jam service check.
"Sensor (fuser output)
See
lingering jam service check."
on page
2-127.
Go to sensor (fuser output)
lingering jam service check.
"Sensor (fuser output)
See
lingering jam service check."
on page
2-127.
Go to sensor (fuser output)
lingering jam service check.
See
"Sensor (fuser output)
lingering jam service check."
on page
2-127.
1. Go to sensor (fuser output)
static jam service check.
See
"Sensor (fuser
output) static jam service
check" on page
2-128.
2. Go to sensor (narrow
media) static jam service
check. See
"Sensor
(narrow media) static jam
service check" on
page
2-130.
Diagnostic information
4062
2-23