Maintenance; Section 6 Maintenance - ESAB Heliarc 353iAC/DC Operating Manual

Table of Contents

Advertisement

6 MAINTENANCE

section 6
maintenance
7. Fill up the cooling unit with coolant to the maximum level.
8. Put the cooling unit in position and connect it.
6.5
Fill up the cooling unit with coolant
To fill up the cooling unit with coolant do the following:
1. Turn of the cooling unit and the power source.
2. Disconnect the cooling unit connector from the power source.
3. Remove the safety bolt (1).
4. Carefully pull out the cooling unit (2), enough to access the coolant tank.
5. Fill up the cooling unit with coolant to the maximum level.
6. Carefully push back the cooling unit and fasten it with the safety bolt (1).
- 29 -
0463 369 001
© ESAB AB 2014
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heliarc 283iac/dcHeliarc 281iac/dc

Table of Contents