8) MAINTENANCE

8.1) Recomendations
The LTG 410 requires little maintenance in normal environment and opperation conditions. It is sufficient to
blow it dry clean using dry compressed air free from oil
After cleaning the equipment with blow dry air, check that the electric connections and components are
properly fixed.
Check for possible faults in the wire isolations or electric cables, including the welding cable and any others
and if any of them is faulty substitute it.
Note:
the high frequency) and should be adjusted to a distance of 0,95 mm between
the electrodes. See picture below.
8.2) Repair
In order to ensure the perfect functioning and performance of a ESAB equipment, use only original parts
supplied by ESAB or approved by them.
All guarantee undertakings from the supplier cease to apply if the customer uses non-original or non -
approved parts when replacing any of them.
Spare parts can be obtained from the ESAB Authorized Services or from its Sales Distributors listed on the
last page of this Manual. Always inform the Equipment Model and Serial Number.
30
LTG 410
The sparkler (the element which causes sparks is needed to generate
once a month
.