Flame Energy MONACO FL063 Installation And Operation Manual page 87

Flame energy monaco fl063 fireplace
Table of Contents

Advertisement

Monaco Installation and Operation Manual
Remove the fireplace's lower
decorative
louver.
Install
the
blocking plate (F) included in the
kit, on the front opening of the air
control
housing.
Using
a
screwdriver,
secure
with
two
screws.
Then, install the flexible pipe* (D)
(not supplied) to the fresh air
intake adapter (B) using one of
the adjustable pipe clamps (C).
Secure the other end of the pipe
to the outside wall termination (E)
using the second adjustable pipe
clamp (C). The outside wall
termination (E) must be installed
outside of the building.
*Use the length required for your
installation while respecting the
maximum length of 30 ft (9 m).
To avoid condensation, it is
recommended
to
use
an
insulated pipe long enough and
containing a "P-Trap" loop. This
configuration can be found inside
the chase, but must at all times
maintain
clearances
to
combustibles.