A noncombustible floor protection with R value insulation equal to or greater than 1.00
must be installed in front of the unit. For more details see Section 6.3.2: Minimum Heart
Extension Requirements. The use of an R value is convenient when more than one
material is going to be used in the hearth extension to cover the combustible surface. This
is because R values are additive, whereas K values are not. To find the corresponding R
factor to use for some selected materials, please see Thermal Characteristics of
Common Floor Protection Materials table.
CAUTION: DO NOT LEAVE CARPET UNDER THE FLOOR PROTECTION IN FRONT
OF THE FIREPLACE
6.3.1.3 R Calculations
There are two ways to calculate the R factor of the floor protection. First, by adding the R-
values of the proposed materials or if some K and thickness values are given, by
converting them to R values.
To calculate the R factor for a composite floor protection made of a combination of
alternative materials, simply add the R-values of those materials. If the result is equal to or
larger than the required R value, the combination is acceptable. For R-values of some
selected materials, see Appendix section.
Example:
Required floor protection R of 1.00. Proposed materials: four inches of brick and one
®
inch of Durock
board:
(R = 4 x 0,2 = 0,8) plus 1 inch of Durock
This R value is larger than the required 1.00 and is therefore acceptable
In the case of a known K and thickness of alternative materials to be used in combination,
convert all K values to R by dividing the thickness of each material by its K value. Add the
R values of your proposed materials as shown in the previous example.
Four inches of brick
0.8 + 0.52 = 1.32.
Example:
K value = 0.75
Thickness = 1
R value = Thickness/K = 1/0.75 = 1.33
®
(R = 1 x 0.52 = 0.52).