8.7 Angled Wall Radiation Shield

When passing through a combustible wall with the chimney at a 30 or 45 angle (30 or
45 in Canada and 30 only in the USA), an angled firestop or wall radiation shield
provided by the chimney manufacturer must be installed. Only one is required. Follow the
chimney manufacturer's installation instructions.
In cold climate locations, it is recommended that you use the insulated wall radiation shield
since it will maintain the home's thermal barrier.

8.8 Chimney Support Installation

8.8.1 Universal Roof Support

This support has three possible uses:
1. It must be used on a roof to support the chimney.
2. It may be used on a floor, ceiling or roof above an offset to support the chimney above
the offset.
3. It may be used on a floor, ceiling or roof as a supplementary support.
INSULATED WALL RADIATION SHIELD
A
GYPROK
B
INSULATED WALL
C