Device Reset
The SocketModem is ready to accept commands after a fixed amount of time ("X" Time) after power-on or reset.
Model
MTSMC-H5
1
The SocketModem may respond to a shorter reset pulse.
RS-232 Signal DC Electrical Characteristics
Units:
Volts
Applies to the following pins:
Pin
Signal Name
J33
-RTS
J34
-RXD
J35
-TXD
J36
-RI
Parameter
3.3 Volt Powered
Input Low Level
Input High Level
Output Low Level
Output High Level
5 Volt Powered
Input Low Level
Input High Level
Output Low Level
Output High Level
Absolute Maximum Rating
All models can run with an input voltage of either 3.3V or 5V. The maximum voltage on any signal pin equals the
input voltage.
Electrical Characteristics Other Pins
Pin
Signal Name
J24
-RESET
J25
USB VBUS
J26
GND
J27
USB DP
J28
USB DN
J41
GND
J48
GPIO0
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
Time Constant
250 ms
Pin
Signal Name
J37
-DSR
J38
-CTS
J39
-DCD
J40
-DTR
Minimum
0
1.5
0
2.35
0
2.3
0
3.7
VIL
Min
Max
0.8
-0.3
0.8
--
--
0.8
0.8
--
--
-0.3
0.8
"X" Time
10 seconds
Maximum
0.55
3.3
0.55
3.3
0.8
5
0.55
5
VIH
VOL
Min
Max
Min
2.0
--
2.0
8.7
--
--
--
--
2
2
--
--
--
2.0
5.5
CHAPTER 3 – SPECIFICATIONS
Minimum Reset Pulse
200 US
VOH
Max
Min
Max
--
--
--
--
--
--
--
--
--
0.3
2.8
0.3
2.8
--
--
--
0.4
2.9
1
10