Page 1
Wireless CDMA Modems MultiModem® CDMA MMCModem™ CDMA SocketModem® CDMA AT Commands IP Commands Fax Commands GPS for CDMA Commands RUIM Commands SIM Toolkit for RUIM Reference Guide...
Page 2
Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Chapter 6 – SIM Card Operational Commands...35 Enter PIN +CPIN ...35 Enter PIN2 +CPIN2 ...36 PIN Remaining Attempt Number +CPINC ...36 Facility Lock +CLCK ...37 Change Password +CPWD ...38 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Contents Table of Contents...
Page 4
Position Determination Privacy Level +WPDPL ...70 Position Determination NV Privacy Level +WPPRV...70 Position Determination Transport Setting +WPTLM...71 Set Position Determination IP Address +WPDIP...71 Set Position Determination Port ID +WPDPT...71 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
Page 5
Select Tone Dialing T ...107 Select Pulse Dialing P ...108 Basic S-Registers S ...108 Error Control Operation +EB ...109 Numeric Parameter Control +EFCS ...109 Error Control Report +ER ...109 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
Page 6
Current Active Profile $QCMIPEP ...132 Return Profile Information $QCMIPGETP ...133 Set NAI for Active Profile $QCMIPNAI ...133 Set Reverse Tunneling $QCMIPRT ...133 Set MN-AAA Shared Secrets in Active Profile $QCMIPMASS...134 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
Page 8
Preparing Data Services +WOAP ...193 Please Retry +WOAR ...193 Display PRI Checksum +WSUM ...194 Reset MIN and MDN to Factory Defaults +WRMM ...194 IOTA Feature Application Note ...195 Index ...196 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
TIA/EIA/IS-707.3: Data Service Options for Wideband Spread Spectrum Systems: AT Command Processing and the Rm Interface IS-131: Data Transmissions Systems and Equipment – Extensions to Asynchronous Dialing and Control. TIA/EIA-592: Asynchronous Facsimile DCE Control Standard – Service Class 2. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 1 – Introduction...
Like the MNP protocols, LAPM uses cyclic redundancy checking (CRC) and retransmission of corrupted data (ARQ) to ensure data reliability. Mobile Country Code. A pre-defined 30-digital number that represents a country in the IMSI. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 1 – Introduction...
Page 11
In this context, it is the device (PDA/Computer) connected to the WISMO Quik. Also see DTE. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) – The R-UIM is similar to a subscriber identity module (SIM), but A SIM card is a portable memory chip.
Page 12
Type of Number/Numbering Plan Identification. TON/NP A data compression algorithm. V24-V25 A data compression algorithm. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 1 – Introduction...
If the command line has been performed successfully, an OK string is returned. • In the following examples <CR> and <CR><LF> are intentionally omitted. • Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Features character. Chapter 2 – At Command Features...
Command syntax: AT+CGSN Syntax: Command AT+CGSN Note: Get the ESN Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible responses Note: No response returned. Note: No response returned. Note: Ready to process commands. Possible Responses +CGMR: S/W VER: WISMOQ WQ1.1 Mar 20 2002 17:30:00 Note: Software Version WISMOQ, revision WQ1.1 generated on the...
This command repeats the previous command. Only the A/ command itself cannot be repeated. Description: Command syntax: A/ Syntax: Command Note: Repeat last command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Command valid +CSCS: “CDMA” Note: Command valid +CSCS: ("CDMA","CUST")
Command AT+CSTA? Note: Get type of address AT+CSTA=? Note: Get supported address types Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Current ring playing is muted. Note: Current ring playing with Max. volume. CRSL:4 Note: Current level is 4 CRSL: (0-4) <type2>...
ATD><mem><index>; Note: A semicolon must be used at the end of the AT command to signal phonebook dialing. Otherwise, the command will result in an error. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Numeric Code (with Description...
NO CARRIER, ...). It can be useful in the case of multiple calls. Command syntax: ATH Syntax: Command Note: Ask for disconnection ATH1 Note: Ask for outgoing call disconnection Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) ATD><index>[;] ATD>[<mem>]<name>[;] ATD>[<mem>]<index>[;] Possible Responses +CPBS: ME,11,100 Note: Command executed Note: Command executed...
ATD1234567; Note: Outgoing voice call while already in a call AT+CEER AT+CEER Note: Ask for reason of release Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 4 – Call Control Commands Possible Responses RING Note: Incoming call +WANS:0...
<X>: (0-9, #,*) Values: Command syntax: AT+WSDT=<X> Syntax: Command AT+WSDT=2 AT+WSDS Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Command valid To send tone sequence 13#, the application sends: AT+VTS=13# Possible Responses Starts DTMF tone Stops DTMF tone Chapter 4 –...
ATS0? Note: Current value ATS0=0 Note: No automatic answer Other S-parameter registers are implemented. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WORG: 8585551212 Note: Last call was a voice call. Command valid Possible Responses Note: Command has been executed...
Syntax: Command AT+VGR=2 AT+VGR? Note: Interrogate value AT+VGR=? Note: Test command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Microphone Relative Gain Step (dB) Possible Responses Note: Command valid +VGT: 2 Note: Current value +VGT : (0-3) Note: Possible values...
Note: Set Echo Cancellation to Ear Seal AT+ECHO=2 Note: Set Echo Cancellation to Headset AT+ECHO=4 Note: Set Echo Cancellation to Handset Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 4 – Call Control Commands Possible Responses +CMUT : (0-1) Note: Enable / disable mute...
Power cycle – this mode persists until power cycle is performed AT+COPS by itself is a short-hand equivalent to AT+COPS=0,0. Note: Syntax on next page. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands command. Possible Responses +CSQ: <rssi>,<fer>...
AT+WBND? Note: Ask for current Band Preference AT+WBND=? AT+WBND=0 Note: Allow Any Band Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +COPS: 0,0 Note: Automatic mode, use PRL order, Permanent +COPS: (0-3),(0-1) Note: Modes: Automatic, CDMA Only, CDMA or AMPS only;...
Note: Enable network registration unsolicited result code AT+CREG? AT+CREG=? Note: Example of the unsolicited result code. MS is searching for a base station. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WRMP: 0 Note: Home only...
Command syntax: AT+WCNM Syntax: Command AT+WCNM Note: Ask for the current NAM Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WNAM: 2 +WCNM: 2 Note: No unsolicited response indicates that NAM 3 is not valid, thus no change in NAM.
AT+COPS=0,0 Note: Changing the mode preference while in Emergency Mode, will result in Emergency Mode being exited Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WSOS: 1 +WSOS: (0-0)
Note: Display current setting. AT+WRMW=1 Note: Enable output of ERI 64 through 127. AT+WRMW? Note: Display current setting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WRMW: (0-1) +WRMW: 0 Note: ERI 64 through 127 suppressed.
‘+CME ERROR: 13’ (SIM failure) is returned after 10 unsuccessful PUK attempts. The SIM card is then out of order and must be replaced by a new one. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: PIN code is correct...
AT+CPINC Note: Get the number of attempts left AT+CPINC? Note: Get the number of attempts left Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 6 – SIM Card Operational Commands Possible Responses Note: PIN2 code is correct Possible Responses...
Note: Get card ID AT+CCID? Note: Get current value AT+CCID=? Note: Get possible value Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 6 – SIM Card Operational Commands Possible Responses Note: PIN1 now 5555 +CME ERROR: 16 Note: PIN incorrect +CPWD:(“SC”,8),(“P2”,8)
Total number of messages locations in <mem1>. <used1> Total number of messages locations in <mem2. <used2> Validity Period of the short message, default value is 167 <vp> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Chapter 7 – Short Messages Commands...
AT+CNMI=2,2,0,0,0 AT+CNMA Note: Acknowledge the message received AT+CNMA Note: Try to acknowledge again Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses +CSMS: <MO>,<MT>,<CB> Note: SMS-MO, SMS-MT and SMS-CB support Possible Responses +CMT:”8587351530”,”02/04/03,11 :06...
AT+CNMI=2,0,0,1,0 Note: <ds>=1 AT+CMGS=”8585551212”<CR> Message to send <ctrl-Z> Note: Send a message in text mode Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses AT+CMTI : “MT”,1 Note: message received +CMT : “8585551212”,”98/10/01,12 :30 00”,129,1,2,0,5<CR><LF>...
Longer message texts will be truncated to 99 characters. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Status of Messages in Memory received unread messages...
Note: characters. Longer message texts will be truncated to 99 characters. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands command.
Note: Longer message texts will be truncated to 99 characters when read. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible responses +CMGS:<mr> Note: Message reference output.
Longer message texts will be truncated to 99 characters when read. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) <ctrl Z> (0x1A) to send the message <ESC>...
Note: Delete it AT+CMGD=1,0 AT+CMGD=1,1 AT+CMGD=1,2 AT+CMGD=1,3 AT+CMGD=1,4 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +CMGW : 5 Note: Message stored with index 5 +CMSS: 1 Note: Successful transmission. One SMS message sent since power up.
AT+CPMS=”SR” Note: Change preferred memory to Status Report AT+WMSC=0,”UREAD” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: BC SMS can be received Note: Only Emergency BC SMS can be received. Reception of all other BC SMS will be stopped.
Command syntax: AT+WUSS = <mode> Syntax: Command AT+WUSS=1 AT+WUSS=0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses Note: Next MSG write will be to index 0 +CMS ERROR: 302 Note: Invalid index (out of range)
Time of arrival – Local Time Command syntax: AT+WSTM = <ts> Syntax: Command AT+WSTM=2 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses Note: Set language to English, encoding to ASCII +CMGW: 4...
AT+CCFC=8585551212 Note: Register to an unconditional call forwarding. AT+CCFC=0 Note: Cancel unconditional call forwarding Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 8 – Supplementary Services Commands Possible Responses Note: Prefix number set. +WORG:*728585551212 +WCNT:3 Note: Call forwarding active for all incoming calls...
Note: Place first call on hold, connect to second party. AT+WFSH Note: Connect all 3 parties. AT+WFSH Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Command syntax AT+WFSH= < phone_number > (for a flash with information) Chapter 8 – Supplementary Services Commands Possible Responses +WORG:8585551212 +WCNT:3 Note: Conversation…...
Note: Data mode requested AT+FCLASS=2.0 Note: Fax class 2 mode requested AT+FCLASS? Note: Current value Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 9 – Data Commands Possible Responses +FCLASS: 0, 2.0 Note: If fax class 1 not supported...
Syntax: Command AT+ILRR=0 Note: Local port rate report disabled Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) for normal voice calls for all types of data calls for all types of fax calls for OTAPA calls for markov, loopback, and test calls...
AT+DR? Note: Display the current value AT+DR=? Note: Display the supported values Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Default is 4096. Specifies the maximum string length to be negotiated. Default is 250. Possible Responses Note: Command valid...
Note: DCD matches the true state of the call. AT&C2 Note: Wink DCD signal on call disconnect Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Transmit data flow control disabled. Remove Xon (0x19) and Xoff (0x17) characters from data stream.
Syntax: Command ATQ0 Note: Result codes are returned ATQ1 Note: Result codes are suppressed Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 10 – V24-V25 Commands Possible Responses Note: Command valid Note: Command valid Possible Responses NO CARRIER...
This is a standard Hayes Command syntax: AT&V Syntax: Command AT&V Note: Display the active parameter settings Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 10 – V24-V25 Commands Possible Responses Note: Command is valid (0 means OK) Note: Command valid ®...
This command writes the current configuration to NV. See table in Chapter 19 for a list of items. Description: Command syntax: AT&W Syntax: Command Possible Responses AT&W Note: Command valid Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 10 – V24-V25 Commands Possible Responses MODEM 800 1900 S/W VER: WISMOQ … +CGSM, +CIS707, …...
Note: Select the MT phonebook (RUIM present). AT+CPBS? Note: Display MT phonebook information. Combination of ME and SM phonebooks. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Index range 1 to 100 Index range 1 to 150 (SIM card) ME start at 1, SM start at 101 (SIM card) Chapter 11 –...
Syntax: Command AT+CPBF=”TES” AT+CPBF=”NEXT” Note: Find entries that start with “NEXT” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 11 – Phone Book Commands Possible Responses Note: ME phonebook selected +CPBU: (1 –100),32,(0-255),12 Note: 100 locations starting at 1, 32 digits maximum, TON/NPI value range is 0-255, and 12 characters for the text.
AT+CPBW=,”8585551212”,145,”Text is too long for this ” Note: Write string to the first open location. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Integer type value depending on the capacity of the currently selected phonebook. Phone number is in ASCII format. Valid characters are 0-9 and *, #, -.
The phone number to search must match that stored in phone book. Partial number searching is not Note: supported and will return an error. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 11 – Phone Book Commands Possible Responses +CPBR:1,”6185551212”,145,”test”...
Command syntax: AT+WDCP=”<call phonebook>” Syntax: Command AT+WDCP? AT+WDCP=? AT+WDCP=”LD” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible responses +WAIP: (0-1) +WAIP: 1 Note: No phonebook commands are allowed. If entered, “+CMEE ERROR: 3” is returned. Note: Access is denied following module reset.
Command AT+WPDPT? Note: Query current PD port id value. AT+WPDPT=4911 Note: Set PD port id value. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Possible responses +WPTLM: (0-1) +WPTLM: 1 Note: Command accepted.
Note: Set to MPC server IP address 12.192.20.210 and port 8888. AT+WMPC? Note: Show current settings. AT+WMPC=? Note: Display command parameter ranges. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Possible Responses +WPDCT: (0-2) +WPDCT: 0 Possible Responses...
Description: be a combination of different bands. Command syntax: AT+WGMM Syntax: Command AT+WGMM Note: Get supported bands Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Possible Responses +WGMI: MODEM Note: Command valid, modem Possible Responses +WGMM: 800 1900 Note: CDMA 800 MHz band and 1900 (PCS) Chapter 13 –...
Activation or deactivation of a +CCED response flow will not affect an existing +CSQ response flow. Likewise, activation or deactivation of a +CSQ response flow will not affect an existing +CCED response flow. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands settings:...
Page 76
+CCED response flow will not affect an existing +CSQ response flow. Likewise, activation or deactivation of a +CSQ response flow will not affect an existing +CCED response flow. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands...
AT+CMER? Note: Display current setting. AT+CMER=1 Note: Enable keypad event reporting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Battery voltage (+Vbatt) being supplied to the Modem. Thermistor level (internal temperature) of the Modem. Internal test use only. External general-purpose user defined input (pin 33).
Note: Play a tone AT+WTONE? Note: Current value AT+WTONE=0 Note: Stop playing AT+WTONE=? Note: Test command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WIOR: 0 GPIO 32 value is 0 46, 47. Possible Responses GPIO value is written Stop playing.
AT+WHWV Note: Request MSM Version Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) This parameter sets the DTMF to play in {0-9,*,#,A,B,C,D} (mandatory if <mode>=1) This parameter sets tone gain. The values are identical to those of the +WTONE (speaker) command (mandatory if <mode>=1).
AT+WSTR=2 Note: Select the status 2 (NETWORK STATUS) AT+WSTR=? Note: Ask the list of possible values Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses Note: Path 1 selected Note: Path 2 selected...
Description: Command syntax: AT+WSSW Syntax: Command AT+WSSW Note: Get Software version Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WCDM: 5,0 Note: Melody n°5 is currently selected, and the buzzer is selected to play it. RING Note: An incoming call occurs, and the melody n°5 is played on the buzzer.
Note: Disable timer AT+WRST=1,”001:03” Note: Enable timer and put delay at 1 hour 3 minutes AT+WRST? Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WCDP : (0-1) +WCDP: 0 Possible Responses ERROR +WRST: 1,”001:03”,”001:01”...
AT+WPRV=0 Note: Set to normal voice call AT+WPRV=1 Note: Request a secure voice call ATD18005551212; Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses Note: Standard Tones are muted +WSST: 4 Note: Current level is 4...
Note: Request current NAM’s PRL version AT+WPRL? Note: Request current NAM’s PRL version The range for PRL is a 16-bit type. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WPIN: 0 Note: PIN disabled...
Note: Set bit 1 to active and bit 0 to inactive. AT+WIOW=41,1 Note: Set GPIO state. AT+WIOW=54,1 Note: Set LED2 state. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WMBP: 1,4 +WMBP: (0-1),(1-30)
SIM Application which menu item is selected. The commands used for this operation are: +STIN (SIM Toolkit Indication) +STGI (SIM Toolkit Get Information) +STGR (SIM Toolkit Give Response) Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 14 – SIM ToolKit...
The +STCR (SIM Toolkit Control response) indication is an unsolicited result sent by the SIM when call control functionality is activated and before the customer application has performed any outgoing call, SMS, SS, or USSD. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) STEP 1: Configuration and Activation...
AT+CPIN? +CPIN: SIM PIN AT+CPIN=0000 OK PIN Ok +WIND: 4 AT+STSF? +STSF: 1,”5FFFFFFF7F”,3 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +CME ERROR: <err> +STSF: <Mode>,<Config>,<Timeout>,<Autoresponse> Enable the reporting of mobile equipment errors Set indications Query ME Status ME is ready.
Menu. AT+STIN? Note: Ask for the last SIM toolkit indication sent by the SIM. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 14 – SIM ToolKit Possible Responses +STIN: 0 Note: the last SIM toolkit indication was a Setup Menu...
Get information about ‘Send USSD’ pro-active command Get information about ‘SETUP EVENT LIST’ pro-active command. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses See following table. +CME ERROR: <err> +STGI: (0-11) Possible Responses +STGI: <Alpha Identifier menu>...
Page 94
Values when Cmd=4 (Setup Call ) <Type> <CalledNb> <SubAdress> <Class> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Menu item Identifier Number of items in the main menu Alpha identifier label of items in ASCII format No help information available Help information available Contains a pro-active command identifier.
Page 95
Text String containing 0x00 0x41, the text displayed is .0041. Error Codes: + CME ERROR: 3 +CME ERROR: 4 +CME ERROR: 518 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Tone Dial Tone Busy Tone Congestion Tone Radio ack...
BEYOND CAPABILITIES UNABLE TO PROCESS NO RESPONSE END SESSION Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable the reporting of mobile equipment errors Set indications SIM ToolKit functionality activated with all facilities. The main menu has been sent from the SIM.
Page 97
+STIN: 0 indication, not after a +STGI=0 request. All of the Terminal Responses are not possible with all of the Proactive Commands. If a Terminal Response is attempted during an incompatible Proactive Command session, a +CME ERROR: 3 will be returned. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 14 – SIM ToolKit...
Page 98
+STGI: 9,1,1 +STIN: 1 AT+STGI=1 +STGI: 0,” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Operation not allowed. This error is returned when a wrong parameter is detected. Operation not supported. This error is returned when the user gives a response with SIM ToolKit functionality not activated.
Some parameters or commands discussed in this chapter may be re-defined by your network carrier. Your carrier will provide these commands for you. See also the printed Activation Notices that accompany the Multi-Tech wireless products. What is Provisioning?
AT+WIMI=310008585551212 Note: Set IMSI to 310008585551212 For RUIM software releases, this command is not valid and will return “Error 3”. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible Responses ERROR Note: Invalid request...
AT+WSCI? Note: Read the current slot cycle index AT+WSCI=1 Note: Set the slot cycle index Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible Responses +WSID: 1, 45, 84 Note: The SID/NID pair 45,84 in location 1 is selected.
Command syntax: AT+WPCC=<channel a number>,<channel b number> Syntax: Command AT+WPCC? Note: Get current primary CDMA channels AT+WPCC=211,432 Note: Set the primary CDMA channels Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WBGP: 127,0,0,1 Possible Responses +WBGS: 127,0,0,1 Possible Responses +WPDS: ”#777”...
Note: Get the Service Options of the current NAM AT+WSOM=1,4,2,2 Note: Set current NAM Service Options Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible responses +WPCC: 691,777 Possible Responses +WSOM: 0, 1, 2, 0...
AT+WSNR? Note: Show last read SID/NID list index. Default: 0. AT+WSNR=? Note: Show SID/NID list index range. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible Responses Note: software reset is performed Possible Responses ERROR Note: Service provisioning code not yet entered.
Note: Activate new Nam2 PRL. AT+DPRL=? Note: Display parameter ranges. AT+DPRL? Note: Display last used parameter values. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible responses Note: Code successfully entered. Note: PRL stored in module.
Note: Set mobile directory number to 8585551212 AT+WCMT=1 Note: Commit all changes performed during this provisioning AT session to non-volatile memory. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Response ERROR Note: Service Programming code not yet entered...
Chapter 16 – Extended AT Commands in IS707.3 Multi-Tech CDMA modem also implements the CDMA AT commands as specified in the TIA/EIA/IS-707.3. Refer to IS707.3 for more information about these commands (range, parameter definition, result codes, etc.). Note: Some of the AT commands may not be supported by the network; please verify with your carrier as to its support of IS707.3 commands.
Value 255: disable carrier detect ATS11? Note: DTMF tone duration and spacing in milliseconds (value: 50-255) Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses Note: Command is valid Possible Responses...
Command AT+ER? Note: Display the current setting. AT+ER=1 Note: Set value to 1. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +EB: 1,0,30 Note: This is the default setting...
Command AT+ESR? Note: Display the current setting. AT+ESR=1 Note: Set value to 1. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +ES: 3, 0, 2 Note: Command is valid...
Command AT+GMM? Note: Display the current setting. AT+GMM Note: Display the model Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +ETBM: 0, 1, 20 Note: Command is valid Note: Command is valid...
AT+GOI Note: Display the responses to the command Currently, no information text is provided. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses ERROR Note: Command is not valid +GMR: S/W VER: WISMOQ WQ1.8, 10015...
Note: Display the current setting. AT+MR=? Note: Display the range of setting. AT+MR=1 Note: Enable reporting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +MS: V32B,1,1200,14400 Note: Command is valid...
Note: Display the current setting. AT+MV18S=1,1,1 Note: Set mode value to 1. AT+MV18S? Note: Display the current setting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +MV18R: 0 Note: Command is valid...
AT+CAD=? Note: Display the available service values. This is a read-only command. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CXT: 0 Note: Command is valid +CXT: (0-1)
Note: Set to 1. This default value for the +CRM parameter shall be 0 if this value is supported by the DCE. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses...
AT+CMIP? Note: Display the current setting AT+CMIP? Note: Display the current setting AT+CMIP Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CBC: 0, 77 Note: Command is valid ERROR...
Command AT+CSS? Note: Display the current setting. AT+CSS=? Note: Display the parameter range. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CBIP: 198.229.142.65 Note: Command is valid Note: No IP address assigned.
Command AT+CHV Note: Display the current setting. AT+CHV0 Note: Hang up the call. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CMUX: C, 2 Note: Command is valid +CMUX: (1-9,A-D,F), (1,2)
Note: Display the current setting. AT+CTA=? Note: Display valid parameter range. AT+CTA=1 Note: Set to one second. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses ERROR Note: Command is not valid...
+FPI: "Polling station IDd" +FPS +FPS:<value> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Fax Connection. The +FCO response indicates that a connection has been made with a Group 3 facsimile station. DCS Frame Information. Reports negotiated parameters; sent after +FDT or +FDR execution but before the CONNECT result code.
+FCR AT+FCR=<0|1> +FIE AT+FIE=<0|1> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Post Page Message. The +FET: response is generated by a receiving facsimile DCE after the receipt of Phase C data and post-page message from the transmitting station when in data reception mode (+FDR).
Page 123
+FBO AT+FBO=<0|1> +FLO AT+FLO=<value> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Copy Quality Checking. The +FCQ command controls the copy quality checking and correction. The sub-parameters control the copy quality checking and correction of data sent to the remote side.
Command AT$QCPREV? Note: Display the current setting AT$QCPREV Note: Display the of value Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses Note: Command is valid Possible Responses...
Command AT$QCPPPD? Note: Display the current setting AT$QCPPPD Note: Dump PPP statistics information Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMTOM: “” Note: Command is valid...
Command AT$QCUDPR? Note: Display the current setting AT$QCUDPR Note: Reset UDP statistics counter Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses ERROR Note: Command is not valid...
AT$QCCLR? Note: Display the current setting AT$QCCLR Note: Clear the mobile error log Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses ERROR Note: Command is not valid...
AT$QCDMR=? Note: Display the range of values AT$QCDMR=115200 Note: Set DM baud rate to 115200 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses +WCNT: 3 Note: Command is valid...
AT$QCSCRM =? Note: Display the range of values AT$QCSCRM =0 Note: Set value to 0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMDR: 3 Note: Command is valid...
AT$QCMIP=? Note: Display the range of values AT$QCMIP=0 Note: Set value to 0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCTRTL: 1 Note: Command is valid...
AT$QCMIPEP=? Note: Display the range of values AT$QCMIPEP=0 Note: Set value to 0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPP: 0 Note: User profile 1 is currently used...
AT$QCMIPRT=? Note: Display the range of values AT$QCMIPRT=1,1 Note: Set value to 1 and commit Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses ERROR Note: Command is not valid...
AT$QCMIPMASSX=? Note: Display the range of values AT$QCMIPMASSX=FF,0 Note: Set value to 0xFF, but not commit Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPMASS: Set Note: Command is valid...
AT$QCMIPMHSPI=? Note: Display the range of values AT$QCMIPMHSPI=5500,0 Note: Set value to 5500, but not commit Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPMHSSX: Set Note: Command is valid...
Note: Display the range of values. AT$QCMIPHA =10.1.2.15,1 Note: Set to 10.1.2.15, and commit to NV. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPPHA: 10.1.1.20, 0 $QCMIPPHA: ((0-255).(0-255).(0-255).(0-255)),(0-1)
A number of standard AT commands are not available when the TCP App feature is in use; that is, a AT+WPPP session has been successfully started. See Chapter 20 for a list of these restricted AT commands. The ERROR result will be returned in their attempted use. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Description...
<port> range 0 to 65535. Response Values <type> <socket> The socket number of the potential connection. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands Possible responses +WPPP:201 (negotiating) +WPPP:200 (connected) Note: PPP session started.
ERROR return will occur after the AT+WTMO specified time value (default 500 milliseconds). Partial payload data for a timed out AT+WSTX command will be discarded. Values: <type> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands Possible responses +WOSK: 0,0 +WSKS: 0,0,1 Note: TCP socket zero is open.
+WPPP: 200 Note: PPP Session established and available. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) The domain name string to lookup. The quotes around the name are required. The same domain name must be specified in the second command.
Invalid PD parameter PD parameter not supported Tracking mode requires +WPDFR setup No active session Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Information Chapter 20 – Reference Information Resulting from the following commands All GSM 07.07 commands (+CME ERROR: 3) All GSM 07.07 commands (+CME ERROR: 4)
Invalid Parameter Operation only allowed during an incoming call Invalid Mode Selection Invalid Roam Selection Invalid Band Selection Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information Resulting from the Following Commands +WPPP +WSTX +CMGS, +CMSS All SMS commands (+CMSS, +CMGL, +CPMS…...
Bad privacy parameter Bad download parameter Bad net access parameter Bad operation parameter Bad number of fixes parameter Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information <code> Description Wrong server Information parameters Error in timeout parameter...
ATIx +IPR +CNUM +CGSN +CMEE +WPRL +CPOF +CFUN Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Note and Explanation Set modem fixed baud rate Display the error code Clock management Battery charge General status indication Set modem local echo...
Description PPP established and available PPP initialization in progress PPP closed or unavailable PPP is closing Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Socket is open Receive data is available Socket is closed Chapter 20 – Reference Information...
+WVSS Verizon system selection AT&F Reset to factory defaults Answer call Call origination ATDL Call origination using last entered number Call termination Reset to default configuration Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information...
Octet 5 contains a value with bit 7 equal to zero. Bits 6 through 0 (010 1101) of this octet correspond to the character dash ‘ - ‘. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Octet 4 Octet 5...
HDLC packets between the two +CMGS packets. AT+CMGD Delete SMS message AT+CCED Cell environment AT+CREG Registration and roaming Unsolicited Messages General unsolicited status or indication messages from the module. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information...
Page 158
AT+CSQ? +CME ERROR: 3 AT+CLCC +CLCC: 0,9,0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable detailed reporting of mobile equipment errors. Host application configured for PPP dial up access. Initiate a data call. Number string is carrier specific.
Refer to the +CCED AT command in Chapter 13 for more information and a definition of the returned values. Response syntax: +CCED: <requested dump> Syntax: Example Result +CCED: 1,725,4,65535,6,,0,,,-104,-35,-63 Note: Cell environment description indication in response to AT+CCED=0,1 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Result Codes Chapter 21 – Unsolicited AT Result Codes...
Response syntax: +CKEV: <key>,<press> Syntax: Example Result +CKEV: 9,0 Note: Indicates key 9 has been released Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Interface Data Compression) for an explanation of +CDS memory.
3 – Emergency Response syntax: +CMTI: <mem>,<index>,<priority> Syntax: Example Result +CMTI: “MT”,5 Note: Normal priority incoming message received and stored in “MT” memory at index 5 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes...
TEST markov, loopback, or test call UNKNOWN unknown/undefined call type Response syntax: +CRING: <Type> Syntax: Example Result +CRING:VOICE Note: Incoming normal voice call. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes...
(only available on networks supporting answering supervision for payphone applications) Response syntax: +WANS:<call type> Syntax: Command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Possible Responses +RING +WANS:0...
This response displays a broadcast message that the carrier may send to all mobiles in an emergency. This Description: event is required for CDMA specifications. Response Syntax: +WFNM=”<message>” Syntax: Command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Possible Responses +WORG:18005551212 +WCNT:3 Note: Call Connected with service option 3...
AT+WIND? Note: Show current setting. AT+WIND=? Note: Show <IndLevel> range. AT+WIND=128 Note: Turn on Network lost indication only. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WFSH R-UIM Presence Reserved Reserved Indication that the product is ready to process all AT commands...
Syntax: Command <nam> NAM 1 NAM 2 NAM 3 NAM 4 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WSOS:1 +WORG:911 Note: Unsolicited +WSOS result confirms Emergency Mode is entered +WSOS:0 Note: Unsolicited +WSOS result confirms Emergency...
Note: Display current power mode state. <state> Leaving power save Entering power save Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WVMI: 1,2 Note: 2 messages are in your voicemail box. Interrogate the status of CPHS functionality...
<velocity vertical> 8-bit signed integer. This value is the vertical speed in units of 0.5 meters per second. The value is in the range 0 to 255 (-64 to +63.5 meters per second). Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +WPDSS: <latitude>,<longitude>,<timestamp>,<position uncertainty angle>, <axis...
Bad privacy parameter Bad download parameter Bad net access parameter Bad operation parameter Bad number of fixes parameter Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Value Uncertainty in Meters 1024 1536...
PRL using the AT command interface. Response Syntax: +DPRL: <status> Syntax: Example Result +DPRL: 0 Note: Downloaded PRL validation successful. <status> Validation successful Validation unsuccessful Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes...
PPP session shutdown. For a broken data pipe situation, the “+++” command can be used to force the module back into command mode. NO CARRIER Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable incoming caller id presentation Display module phone number...
AT+CMGR=1 +CMGR:"REC UNREAD","8585552222","02/05/15,15 :54 :04",1,2,0,”5550000”,15 Test message #2 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) SMS-DELIVER stored in NV, SMS-STATUS-REPORT routed to TE New message received and stored in “MT” memory at index 0 SMS-DELIVER routed to TE Received message.
AT+WPDDD=0,10 AT+WPDST=3 AT+WPDSS=“PVH”,60,50 +WPDSS:#,#,#,#,#,#,1,7,#,#,#,#,# < end loop> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Session type is single-shot Accuracy optimal operation mode Display privacy setting Privacy is set to allow all Set gpsOne transport level (DBM); carrier specific capability...
… Transmission of page data … 0x10 0x03 AT+FET=2 +FPS:<status> +FHS:<status> NO CARRIER Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable extended result codes Select fax class 2 Set flow control Set identifier string Set message reporting Set capability to receive...
Page 177
AT+WCSK=0,1 +WSKS: 0,1,4 AT+WGSS=0 +WGSS: 0,2,1,2,0,0,0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable detailed reporting of mobile equipment errors. Display TCP connection status. TCP status, PPPstate “closed”, RxMode “Unsolicited”, All sockets “closed”. Set TCP receive mode; polled received data.
Page 178
… +WSKS: 1,0,1 AT+WSTX=1,0,500,<data> +WSTX: 0,500 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Set UDP receive mode; unsolicited received data. Start a SIP data call and open a PPP session. Unsolicited response; PPP session startup in progress. Unsolicited response; PPP session established and available.
Page 179
AT+WOSK=1,216,37,68,117,250 +WOSK: 1,0 +WSKS: 1,0,1 … Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Other +WSTX commands and +WSTX responses for data transfers. Send 500 bytes of data on UDP socket zero. Lost UDP socket zero connection. Display UDP connection status.
<data> (text mode) Example Result +CMT: “123456”,”98/10/01,12 :3000+00”,129,1,2,0,”5550000”,5<CR><LF> Hello Note: Incoming message received Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Message type indicator Status report MO delivery acknowledge message Message Reference Recipient Address Type-of-Address of <ra>...
<text> Command Note: Example of acquiring service with enhanced roaming. Note: Example of acquiring service without enhanced roaming. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Bit Length Character Encoding Octet, unspecified see IS-91 IS-91 Extended Protocol Message 7-bit ASCII (ANSI x3.4)
Urgent Emergency <privacy> Message privacy: Normal Restricted Confidential Secret Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WSOS:1 +WORG:911 Note: Unsolicited +WSOS result confirms Emergency Mode is entered +WSOS:0 Note: Unsolicited +WSOS result confirms Emergency Mode is exited...
<lang> <encod> Encoding <length> Length of the text message (in bytes). Message text <data> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +CMTI: “MT”,1 Note: New message received +CMGR: “REC UNREAD”,”8585551212”, ”98/10/01,18 :22 :11+00”,1,2,0,0,0,”8585550000”,9<CR><LF>...
Note: Send a message with the specified priority, privacy, reply option and call back number. Notice length field is omitted. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +CMGL: 1,”REC UNREAD”,”8585551212”,1,2,15...
AT+WSPC=1,111111 Note: Enter service programming code 111111 AT+WSPC=1,000000 Note: Enter service programming code 000000 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +CMGW: 4 Note: Message stored in index 4 +CMGW: <index>...
This response will be accompanied by three quick audio tones from the speaker. Response Syntax: +WOT3: “Programming Unsuccessful” Syntax: Possible Responses +WOT3: “Programming Unsuccessful” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WVSS: (0-3) +WVSS: 1 Note: Home only mode set.
Response Syntax: +WLCK: “Excess SPC failures!” Syntax: Command AT+WSPC=0,123456 Note: 15 attempt to enter the SPC. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WLCK: “Excess SPC failures!” Note: Modem now in offline mode.
Note: Display valid parameter range AT+WPLCK? Note: Request current setting type AT+WPLCK=3 Note: Select lock all Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WPLCK: (0-3) +WPLCK: 0 Note: Command successful...
Note: Ask for current functionality level AT+CFUN=0 Note: Set phone offline AT+CFUN=1 Note: Set phone ONLINE. A software reset is performed. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Message type indicator Status report MO delivery acknowledge message Message Reference Recipient Address Type-of-Address of <ra>...
Note: Bar Incoming Calls AT+CLCK=”AO”,9 Note: Query outgoing call barring status Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Note: <raw rssi>, <raw Ec/lo>, and <fer> as defined above BAOC (Bar Outgoing Calls) Allow all outgoing calls Allow outgoing calls only for phonebook entries (use ATD> command) and emergency...
(Base Station Protocol Revision In Use – Band Class 1/PCS) <BS_P_REV> J-STD-008C IS-95B IS-2000 IS-2000A 0 – Max RF Channel Number <CHANNEL> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Possible Responses +WMDN: 8581111111...
AT+WDPXY=68.28.31.1 Note: Set the proxy server address value. AT+ WDPXY =”” Note: Set invalid address value. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Possible Responses +CSS: 2, A, 4145, 6, 334...
Syntax: Command AT+WRMM Note: Reset MIN and MDN to factory defaults. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Possible Responses +WSUM: 0004DDCF Note: The displayed value is a eight digit hexadecimal number.
If the IOTA provisioning session fails, the unsolicited response +WOEA: "IOTA error 1012" will be displayed. Verify that configuration parameter values have been properly entered and that appropriate PRI data is being used. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Value http://hcmci.iota.spcsdns.net:8080/ciip...
&D Data Terminal Ready Signal ...60 &F Restore Factory Setting ...62 &S Data Set Ready Signal ...60 &T Audio Loopback ...61 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Index &V Display Configuration ...61 &W Save Configuration...62 + WSID SID and NID...101 +ADC Analog Digital Converters Measurements ...77...
Page 197
+SIDET Side Tone Modification ...28 +SPEAKER Speaker & Microphone Selection ...27 +STCR Unsolicited Result SIM ...96 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +STGI SIM ToolKit Get Information ...93 +STGR SIM ToolKit Give Response ...96 +STIN SIM ToolKit Indication ...92 +STSF SIM ToolKit Set Facilities ...91...
Page 198
+WTMO Configure Socket Transmit Timeout...141 +WTMR View Modem Timers ...19 +WTONE Play Tone...78 +WTTY TTY Mode ...28 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +WUSS Change SMS Status...49 +WVMI Voice Mail Indicator ...168 +WVSS Verizon® System Selection ...186 2G ...10...
Page 199
Examples of General AT Command Usage ...172 Excess SPC Failures +WLCK ...187 Extended AT Commands ...107 Extended Error Report +CEER ...22 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Extended Error Report (+CEER) Call Processing Codes ...148 Extended Roam Indicators +WRMW ...34 Facility Lock +CLCK...37, 190...
Page 200
OTKSL ...100 P Select Pulse Dialing ...108 Packet Dial String +WPDS ...102 Packet Zone Identifier +PZID ...192 Parameters Storage ...151 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Passwords ...35 PD ...11 PDU ...11 Personal Identification Number ...35 Phone Activity Status +CPAS ...16 Phone Offline +CPOF ...16...
Page 201
Set IMSI +WIMI ...100 Set Medium Data Rate $QCMDR ...130 Set MN-AAA Shared Secrets in Active Profile $QCMIPMASPI...135 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Set MN-HA Shared Secrets in Active Profile $QCMIPMHSPI ...135 Set NAI for Active Profile $QCMIPNAI ...133 Set Phone Functionality +CFUN ...189...
Page 202
V DCE Response Format...61 V.18 Reporting Control +MV18R...114 V.18 Selection +MV18S ...114 V.42...109 V24-V25 ...12 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) V42...12 Verizon® Specific AT Commands ...180 Verizon® System Selection +WVSS ...186 View Modem Timers +WTMR ...19 Voice Mail Indicator +WVMI ...168...
Need help?
Do you have a question about the MTCBA-C-IP-N12 and is the answer not in the manual?
Questions and answers