Multitech MTCBA-C-IP-N12 Reference Manual

Multitech MTCBA-C-IP-N12 Reference Manual

Cdma modems multimodem, mmcmodem, socketmodem series
Table of Contents

Advertisement

Quick Links

Wireless CDMA Modems
MultiModem® CDMA
MMCModem™ CDMA
SocketModem® CDMA
AT Commands
IP Commands
Fax Commands
GPS for CDMA Commands
RUIM Commands
SIM Toolkit for RUIM
Reference Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTCBA-C-IP-N12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Multitech MTCBA-C-IP-N12

  • Page 1 Wireless CDMA Modems MultiModem® CDMA MMCModem™ CDMA SocketModem® CDMA AT Commands IP Commands Fax Commands GPS for CDMA Commands RUIM Commands SIM Toolkit for RUIM Reference Guide...
  • Page 2 Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
  • Page 3: Table Of Contents

    Chapter 6 – SIM Card Operational Commands...35 Enter PIN +CPIN ...35 Enter PIN2 +CPIN2 ...36 PIN Remaining Attempt Number +CPINC ...36 Facility Lock +CLCK ...37 Change Password +CPWD ...38 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Contents Table of Contents...
  • Page 4 Position Determination Privacy Level +WPDPL ...70 Position Determination NV Privacy Level +WPPRV...70 Position Determination Transport Setting +WPTLM...71 Set Position Determination IP Address +WPDIP...71 Set Position Determination Port ID +WPDPT...71 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
  • Page 5 Select Tone Dialing T ...107 Select Pulse Dialing P ...108 Basic S-Registers S ...108 Error Control Operation +EB ...109 Numeric Parameter Control +EFCS ...109 Error Control Report +ER ...109 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
  • Page 6 Current Active Profile $QCMIPEP ...132 Return Profile Information $QCMIPGETP ...133 Set NAI for Active Profile $QCMIPNAI ...133 Set Reverse Tunneling $QCMIPRT ...133 Set MN-AAA Shared Secrets in Active Profile $QCMIPMASS...134 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
  • Page 7 Incoming Call +CRING ...162 RxLev Indication +CSQ ...163 Incoming Call +RING ...163 Call Answered +WANS ...163 Call Connected +WCNT ...164 Call Ended +WEND...164 Feature Notification Message +WFNM ...164 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
  • Page 8 Preparing Data Services +WOAP ...193 Please Retry +WOAR ...193 Display PRI Checksum +WSUM ...194 Reset MIN and MDN to Factory Defaults +WRMM ...194 IOTA Feature Application Note ...195 Index ...196 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Table of Contents...
  • Page 9: Chapter 1 - Introduction

    TIA/EIA/IS-707.3: Data Service Options for Wideband Spread Spectrum Systems: AT Command Processing and the Rm Interface IS-131: Data Transmissions Systems and Equipment – Extensions to Asynchronous Dialing and Control. TIA/EIA-592: Asynchronous Facsimile DCE Control Standard – Service Class 2. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 1 – Introduction...
  • Page 10: Terminology And Acronyms

    Like the MNP protocols, LAPM uses cyclic redundancy checking (CRC) and retransmission of corrupted data (ARQ) to ensure data reliability. Mobile Country Code. A pre-defined 30-digital number that represents a country in the IMSI. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 1 – Introduction...
  • Page 11 In this context, it is the device (PDA/Computer) connected to the WISMO Quik. Also see DTE. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) – The R-UIM is similar to a subscriber identity module (SIM), but A SIM card is a portable memory chip.
  • Page 12 Type of Number/Numbering Plan Identification. TON/NP A data compression algorithm. V24-V25 A data compression algorithm. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 1 – Introduction...
  • Page 13: Chapter 2 - At Command Features

    If the command line has been performed successfully, an OK string is returned. • In the following examples <CR> and <CR><LF> are intentionally omitted. • Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Features character. Chapter 2 – At Command Features...
  • Page 14: Chapter 3 - General Commands

    Command syntax: AT+CGSN Syntax: Command AT+CGSN Note: Get the ESN Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible responses Note: No response returned. Note: No response returned. Note: Ready to process commands. Possible Responses +CGMR: S/W VER: WISMOQ WQ1.1 Mar 20 2002 17:30:00 Note: Software Version WISMOQ, revision WQ1.1 generated on the...
  • Page 15: Select Te Character Set +Cscs

    This command repeats the previous command. Only the A/ command itself cannot be repeated. Description: Command syntax: A/ Syntax: Command Note: Repeat last command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Command valid +CSCS: “CDMA” Note: Command valid +CSCS: ("CDMA","CUST")
  • Page 16: Phone Offline +Cpof

    AT+CMEE=0 Note: Disable MS error reports, use only « ERROR » AT+CMEE=1 Note: Enable «+CME ERROR: <xxx>» or «+CMS ERROR: <xxx>» Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 3 – General Commands Possible Responses +CPOF: Note: Command valid...
  • Page 17: Keypad Control +Ckpd

    Note: Play voice call melody index 2 with volume level 2. AT+CRMP=0,,,0 Note: Stop the melody. AT+CRMP=? Note: supported parameters Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Key sequence allowed Note: Sequence not allowed +CME ERROR 3...
  • Page 18: Ringer Sound Level +Crsl

    Command AT+CSTA? Note: Get type of address AT+CSTA=? Note: Get supported address types Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Current ring playing is muted. Note: Current ring playing with Max. volume. CRSL:4 Note: Current level is 4 CRSL: (0-4) <type2>...
  • Page 19: View Modem Timers +Wtmr

    Response syntax: +WTMR: <Uptime>,<Call Time>, <Call Count>, <Last Call Time> Command AT+WTMR Note: Display modem timers Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) seconds since modem boot-up total call seconds since modem manufacture (excluding SMS) total calls made since modem manufacture...
  • Page 20: Chapter 4 - Call Control Commands

    ATD><mem><index>; Note: A semicolon must be used at the end of the AT command to signal phonebook dialing. Otherwise, the command will result in an error. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Numeric Code (with Description...
  • Page 21: Hang-Up Command H

    NO CARRIER, ...). It can be useful in the case of multiple calls. Command syntax: ATH Syntax: Command Note: Ask for disconnection ATH1 Note: Ask for outgoing call disconnection Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) ATD><index>[;] ATD>[<mem>]<name>[;] ATD>[<mem>]<index>[;] Possible Responses +CPBS: ME,11,100 Note: Command executed Note: Command executed...
  • Page 22: Answer A Call A

    ATD1234567; Note: Outgoing voice call while already in a call AT+CEER AT+CEER Note: Ask for reason of release Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 4 – Call Control Commands Possible Responses RING Note: Incoming call +WANS:0...
  • Page 23: Dtmf Signals +Vtd, +Vts

    <X>: (0-9, #,*) Values: Command syntax: AT+WSDT=<X> Syntax: Command AT+WSDT=2 AT+WSDS Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Command valid To send tone sequence 13#, the application sends: AT+VTS=13# Possible Responses Starts DTMF tone Stops DTMF tone Chapter 4 –...
  • Page 24: Redial Last Telephone Number Dl

    ATS0? Note: Current value ATS0=0 Note: No automatic answer Other S-parameter registers are implemented. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WORG: 8585551212 Note: Last call was a voice call. Command valid Possible Responses Note: Command has been executed...
  • Page 25: Incoming Call Bearer +Cicb

    AT+CSNS=2 Note: Force a voice call AT+CSNS? Note: Interrogate value AT+CSNS=? Note: Test command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 4 – Call Control Commands Possible Responses Note: Command accepted Note: Command accepted +CICB: 2 Note: Default incoming bearer: voice call...
  • Page 26: Microphone Gain +Vgt

    Syntax: Command AT+VGR=2 AT+VGR? Note: Interrogate value AT+VGR=? Note: Test command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Microphone Relative Gain Step (dB) Possible Responses Note: Command valid +VGT: 2 Note: Current value +VGT : (0-3) Note: Possible values...
  • Page 27: Microphone Mute Control +Cmut

    Note: Set Echo Cancellation to Ear Seal AT+ECHO=2 Note: Set Echo Cancellation to Headset AT+ECHO=4 Note: Set Echo Cancellation to Handset Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 4 – Call Control Commands Possible Responses +CMUT : (0-1) Note: Enable / disable mute...
  • Page 28: Side Tone Modification +Sidet

    Command syntax: AT+WTTY Syntax: Command AT+WTTY Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: Command valid +SIDET: 1,0 Note: Command valid Possible Responses...
  • Page 29: Chapter 5 - Network Service Commands

    Power cycle – this mode persists until power cycle is performed AT+COPS by itself is a short-hand equivalent to AT+COPS=0,0. Note: Syntax on next page. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands command. Possible Responses +CSQ: <rssi>,<fer>...
  • Page 30: Band Preference +Wbnd

    AT+WBND? Note: Ask for current Band Preference AT+WBND=? AT+WBND=0 Note: Allow Any Band Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +COPS: 0,0 Note: Automatic mode, use PRL order, Permanent +COPS: (0-3),(0-1) Note: Modes: Automatic, CDMA Only, CDMA or AMPS only;...
  • Page 31: Roam Preference +Wrmp

    Note: Enable network registration unsolicited result code AT+CREG? AT+CREG=? Note: Example of the unsolicited result code. MS is searching for a base station. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WRMP: 0 Note: Home only...
  • Page 32: Change Nam Selection +Wnam

    Command syntax: AT+WCNM Syntax: Command AT+WCNM Note: Ask for the current NAM Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WNAM: 2 +WCNM: 2 Note: No unsolicited response indicates that NAM 3 is not valid, thus no change in NAM.
  • Page 33: Emergency Mode +Wsos

    AT+COPS=0,0 Note: Changing the mode preference while in Emergency Mode, will result in Emergency Mode being exited Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WSOS: 1 +WSOS: (0-0)
  • Page 34: Extended Roam Indication +Wrmw

    Note: Display current setting. AT+WRMW=1 Note: Enable output of ERI 64 through 127. AT+WRMW? Note: Display current setting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 5 – Network Service Commands Possible Responses +WRMW: (0-1) +WRMW: 0 Note: ERI 64 through 127 suppressed.
  • Page 35: Chapter 6 - Sim Card Operational Commands

    ‘+CME ERROR: 13’ (SIM failure) is returned after 10 unsuccessful PUK attempts. The SIM card is then out of order and must be replaced by a new one. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: PIN code is correct...
  • Page 36: Enter Pin2 +Cpin2

    AT+CPINC Note: Get the number of attempts left AT+CPINC? Note: Get the number of attempts left Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 6 – SIM Card Operational Commands Possible Responses Note: PIN2 code is correct Possible Responses...
  • Page 37: Facility Lock +Clck

    Note: Bar Outgoing Calls AT+CLCK=”AI”,1,1234 Note: Bar Incoming Calls AT+CLCK=”AO”,2 Note: Query outgoing call barring status Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 6 – SIM Card Operational Commands Possible Responses Note: SIM PIN enabled +CLCK:(“SC”,1),(“FD”,0),(“AO”,1),(“AI”,1) Note: SIM PIN is enabled, SIM FDN feature is disabled,...
  • Page 38: Change Password +Cpwd

    Note: Get card ID AT+CCID? Note: Get current value AT+CCID=? Note: Get possible value Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 6 – SIM Card Operational Commands Possible Responses Note: PIN1 now 5555 +CME ERROR: 16 Note: PIN incorrect +CPWD:(“SC”,8),(“P2”,8)
  • Page 39: Chapter 7 - Short Messages Commands

    Total number of messages locations in <mem1>. <used1> Total number of messages locations in <mem2. <used2> Validity Period of the short message, default value is 167 <vp> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Chapter 7 – Short Messages Commands...
  • Page 40: Select Message Service +Csms

    AT+CNMI=2,2,0,0,0 AT+CNMA Note: Acknowledge the message received AT+CNMA Note: Try to acknowledge again Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses +CSMS: <MO>,<MT>,<CB> Note: SMS-MO, SMS-MT and SMS-CB support Possible Responses +CMT:”8587351530”,”02/04/03,11 :06...
  • Page 41: Preferred Message Storage +Cpms

    Command syntax: AT+CSDH Syntax: Command AT+CSDH? Note: Current value Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands card. Possible Responses +CPMS: (“MT”,”BC”,”SR”),(“MO”) Note: Read, list, delete: SMS, CBM or SMS Status Report. Write, send: SMS +CPMS: “MT”,3,30,”MO”,3,30...
  • Page 42: New Message Indication +Cnmi

    AT+CNMI=2,0,0,1,0 Note: <ds>=1 AT+CMGS=”8585551212”<CR> Message to send <ctrl-Z> Note: Send a message in text mode Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses AT+CMTI : “MT”,1 Note: message received +CMT : “8585551212”,”98/10/01,12 :30 00”,129,1,2,0,5<CR><LF>...
  • Page 43: Read Message +Cmgr

    Longer message texts will be truncated to 99 characters. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Status of Messages in Memory received unread messages...
  • Page 44: List Message +Cmgl

    Note: characters. Longer message texts will be truncated to 99 characters. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands command.
  • Page 45: Send Message +Cmgs

    Note: Longer message texts will be truncated to 99 characters when read. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible responses +CMGS:<mr> Note: Message reference output.
  • Page 46: Write Message To Memory +Cmgw

    Longer message texts will be truncated to 99 characters when read. The maximum message text length for all other software editions is 160 characters. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) <ctrl Z> (0x1A) to send the message <ESC>...
  • Page 47: Send Message From Storage +Cmss

    Note: Delete it AT+CMGD=1,0 AT+CMGD=1,1 AT+CMGD=1,2 AT+CMGD=1,3 AT+CMGD=1,4 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +CMGW : 5 Note: Message stored with index 5 +CMSS: 1 Note: Successful transmission. One SMS message sent since power up.
  • Page 48: Select Broadcast Messages +Cscb

    AT+CPMS=”SR” Note: Change preferred memory to Status Report AT+WMSC=0,”UREAD” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses Note: BC SMS can be received Note: Only Emergency BC SMS can be received. Reception of all other BC SMS will be stopped.
  • Page 49: Message Overwriting +Wmgo

    Command syntax: AT+WUSS = <mode> Syntax: Command AT+WUSS=1 AT+WUSS=0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses Note: Next MSG write will be to index 0 +CMS ERROR: 302 Note: Invalid index (out of range)
  • Page 50: Set Sms Compose Language And Encoding +Wscl

    Time of arrival – Local Time Command syntax: AT+WSTM = <ts> Syntax: Command AT+WSTM=2 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 7 – Short Messages Commands Possible Responses Note: Set language to English, encoding to ASCII +CMGW: 4...
  • Page 51: Chapter 8 - Supplementary Services Commands

    AT+CCFC=8585551212 Note: Register to an unconditional call forwarding. AT+CCFC=0 Note: Cancel unconditional call forwarding Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 8 – Supplementary Services Commands Possible Responses Note: Prefix number set. +WORG:*728585551212 +WCNT:3 Note: Call forwarding active for all incoming calls...
  • Page 52: Calling Line Identification Restriction +Clir

    Note: Enable CLIP AT+CLIP? Note: Ask for current functionality AT+CLIP=0 Note: Disable CLIP presentation Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 8 – Supplementary Services Commands Possible Responses Note: Command valid +CLIR :<mode> Note: <mode> as defined below...
  • Page 53: Send Flash To Base Station +Wfsh

    Note: Place first call on hold, connect to second party. AT+WFSH Note: Connect all 3 parties. AT+WFSH Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Command syntax AT+WFSH= < phone_number > (for a flash with information) Chapter 8 – Supplementary Services Commands Possible Responses +WORG:8585551212 +WCNT:3 Note: Conversation…...
  • Page 54: List Current Call State +Clcc

    (MO) call Command syntax: AT+CLCC Syntax: Command AT+CLCC Note: Seek current phone state Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +CLCC: <state>, <mode>, <termination> Possible Responses +CLCC: 0,9,0 Note: Command valid Chapter 8 – Supplementary Services Commands...
  • Page 55: Chapter 9 - Data Commands

    Note: Data mode requested AT+FCLASS=2.0 Note: Fax class 2 mode requested AT+FCLASS? Note: Current value Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 9 – Data Commands Possible Responses +FCLASS: 0, 2.0 Note: If fax class 1 not supported...
  • Page 56: Cellular Result Codes +Crc

    Syntax: Command AT+ILRR=0 Note: Local port rate report disabled Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) for normal voice calls for all types of data calls for all types of fax calls for OTAPA calls for markov, loopback, and test calls...
  • Page 57: Bis Data Compression +Ds

    AT+DR? Note: Display the current value AT+DR=? Note: Display the supported values Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Default is 4096. Specifies the maximum string length to be negotiated. Default is 250. Possible Responses Note: Command valid...
  • Page 58: Chapter 10 - V24-V25 Commands

    Command AT+ICF=3,3 Note: Set values. AT+ICF? Note: Display current settings. AT+ICF=? Note: Display valid parameter ranges. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Possible Responses +IPR: 9600 Note: Current rate is 9600 bps +IPR: (0,1200,2400,4800,9600,19200), (45,50,75, 110,150,300,600,38400,57600,115200,230400)
  • Page 59: Dte-Dce Local Flow Control +Ifc

    Note: DCD matches the true state of the call. AT&C2 Note: Wink DCD signal on call disconnect Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Transmit data flow control disabled. Remove Xon (0x19) and Xoff (0x17) characters from data stream.
  • Page 60: Set Dtr Signal &D

    Syntax: Command ATQ0 Note: Result codes are returned ATQ1 Note: Result codes are suppressed Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 10 – V24-V25 Commands Possible Responses Note: Command valid Note: Command valid Possible Responses NO CARRIER...
  • Page 61: Dce Response Format V

    This is a standard Hayes Command syntax: AT&V Syntax: Command AT&V Note: Display the active parameter settings Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 10 – V24-V25 Commands Possible Responses Note: Command is valid (0 means OK) Note: Command valid ®...
  • Page 62: Request Identification Information I

    This command writes the current configuration to NV. See table in Chapter 19 for a list of items. Description: Command syntax: AT&W Syntax: Command Possible Responses AT&W Note: Command valid Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 10 – V24-V25 Commands Possible Responses MODEM 800 1900 S/W VER: WISMOQ … +CGSM, +CIS707, …...
  • Page 63: Chapter 11 - Phone Book Commands

    Note: Select the MT phonebook (RUIM present). AT+CPBS? Note: Display MT phonebook information. Combination of ME and SM phonebooks. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Index range 1 to 100 Index range 1 to 150 (SIM card) ME start at 1, SM start at 101 (SIM card) Chapter 11 –...
  • Page 64: Return Selected Phonebook Locations +Cpbu

    Syntax: Command AT+CPBF=”TES” AT+CPBF=”NEXT” Note: Find entries that start with “NEXT” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 11 – Phone Book Commands Possible Responses Note: ME phonebook selected +CPBU: (1 –100),32,(0-255),12 Note: 100 locations starting at 1, 32 digits maximum, TON/NPI value range is 0-255, and 12 characters for the text.
  • Page 65: Write Phonebook Entry +Cpbw

    AT+CPBW=,”8585551212”,145,”Text is too long for this ” Note: Write string to the first open location. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Integer type value depending on the capacity of the currently selected phonebook. Phone number is in ASCII format. Valid characters are 0-9 and *, #, -.
  • Page 66: Phonebook Read +Cpbr

    The phone number to search must match that stored in phone book. Partial number searching is not Note: supported and will return an error. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 11 – Phone Book Commands Possible Responses +CPBR:1,”6185551212”,145,”test”...
  • Page 67: Avoid Phonebook Initialization +Waip

    Command syntax: AT+WDCP=”<call phonebook>” Syntax: Command AT+WDCP? AT+WDCP=? AT+WDCP=”LD” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible responses +WAIP: (0-1) +WAIP: 1 Note: No phonebook commands are allowed. If entered, “+CMEE ERROR: 3” is returned. Note: Access is denied following module reset.
  • Page 68: Chapter 12 - Position Determination (Gps) Commands

    Note: Select the last position info available AT+WPDST=1 Note: Select single-shot fix AT+WPDST=? Note: Display valid command parameter range. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Commands Possible Responses +WPDST: 0 Note: Command accepted.
  • Page 69: Position Determination Operating Mode +Wpdom

    Note: Display current settings AT+WPDDD=0,60 Note: Request single-shot data download AT+WPDDD=1,30 Note: Request continuous data download Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Possible responses +WPDOM: 5 Note: Current mode displayed.
  • Page 70: Position Determination Fix Rate +Wpdfr

    Command AT+WPPRV=? Note: Display valid parameter range. AT+WPPRV? Note: Display current setting. AT+WPPRV=1 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Possible responses +WPDPL: (0-2) +WPDPL: 0 Note: Command accepted. Possible responses...
  • Page 71: Position Determination Transport Setting +Wptlm

    Command AT+WPDPT? Note: Query current PD port id value. AT+WPDPT=4911 Note: Set PD port id value. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Possible responses +WPTLM: (0-1) +WPTLM: 1 Note: Command accepted.
  • Page 72: Position Determination Start Session +Wpdss

    Command syntax: AT+WPDES Syntax: Command AT+WPDES Note: End current PD session Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Advanced Forward Link Trilateration Possible responses Note: Command accepted. Note: Command accepted.
  • Page 73: Gpsone Session Consent +Wpdct

    Note: Set to MPC server IP address 12.192.20.210 and port 8888. AT+WMPC? Note: Show current settings. AT+WMPC=? Note: Display command parameter ranges. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 12 – Postion Determination (GPS) Commands Possible Responses +WPDCT: (0-2) +WPDCT: 0 Possible Responses...
  • Page 74: Chapter 13 - Specific At Commands

    Description: be a combination of different bands. Command syntax: AT+WGMM Syntax: Command AT+WGMM Note: Get supported bands Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Possible Responses +WGMI: MODEM Note: Command valid, modem Possible Responses +WGMM: 800 1900 Note: CDMA 800 MHz band and 1900 (PCS) Chapter 13 –...
  • Page 75: Cell Environment And Rxlev Indication +Cced

    Activation or deactivation of a +CCED response flow will not affect an existing +CSQ response flow. Likewise, activation or deactivation of a +CSQ response flow will not affect an existing +CCED response flow. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands settings:...
  • Page 76 +CCED response flow will not affect an existing +CSQ response flow. Likewise, activation or deactivation of a +CSQ response flow will not affect an existing +CCED response flow. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands...
  • Page 77: Analog Digital Converters Measurements +Adc

    AT+CMER? Note: Display current setting. AT+CMER=1 Note: Enable keypad event reporting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Battery voltage (+Vbatt) being supplied to the Modem. Thermistor level (internal temperature) of the Modem. Internal test use only. External general-purpose user defined input (pin 33).
  • Page 78: Read Gpio Value +Wior

    Note: Play a tone AT+WTONE? Note: Current value AT+WTONE=0 Note: Stop playing AT+WTONE=? Note: Test command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WIOR: 0 GPIO 32 value is 0 46, 47. Possible Responses GPIO value is written Stop playing.
  • Page 79: Play Dtmf Tone +Wdtmf

    AT+WHWV Note: Request MSM Version Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) This parameter sets the DTMF to play in {0-9,*,#,A,B,C,D} (mandatory if <mode>=1) This parameter sets tone gain. The values are identical to those of the +WTONE (speaker) command (mandatory if <mode>=1).
  • Page 80: Select Voice Gain +Wsvg

    AT+WSTR=2 Note: Select the status 2 (NETWORK STATUS) AT+WSTR=? Note: Ask the list of possible values Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses Note: Path 1 selected Note: Path 2 selected...
  • Page 81: Ring Indicator Mode +Wrim

    Command AT+W32K=1 Note: Enable 32kHz sleep mode AT+W32K=0 Note: Disable 32kHz sleep mode Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses Note: up-down RI mode selected Note: pulse RI mode selected...
  • Page 82: Change Default Melody +Wcdm

    Description: Command syntax: AT+WSSW Syntax: Command AT+WSSW Note: Get Software version Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WCDM: 5,0 Note: Melody n°5 is currently selected, and the buzzer is selected to play it. RING Note: An incoming call occurs, and the melody n°5 is played on the buzzer.
  • Page 83: Custom Character Set Tables +Wccs

    Syntax: Command AT+CPHS=<Mode>,<FctId> AT+CPHS? AT+CPHS=? Note: display the range of values Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WCCS: 11, 78797A2020202020097E05 Note: 11 characters displayed Note: Edit successful Note: Edit successful...
  • Page 84: Change Default Player +Wcdp

    Note: Disable timer AT+WRST=1,”001:03” Note: Enable timer and put delay at 1 hour 3 minutes AT+WRST? Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WCDP : (0-1) +WCDP: 0 Possible Responses ERROR +WRST: 1,”001:03”,”001:01”...
  • Page 85: Set Standard Tone +Wsst

    AT+WPRV=0 Note: Set to normal voice call AT+WPRV=1 Note: Request a secure voice call ATD18005551212; Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses Note: Standard Tones are muted +WSST: 4 Note: Current level is 4...
  • Page 86: Security Pin +Wpin

    Note: Request current NAM’s PRL version AT+WPRL? Note: Request current NAM’s PRL version The range for PRL is a 16-bit type. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WPIN: 0 Note: PIN disabled...
  • Page 87: Minute Alert +Wmbp

    Note: Set bit 1 to active and bit 0 to inactive. AT+WIOW=41,1 Note: Set GPIO state. AT+WIOW=54,1 Note: Set LED2 state. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WMBP: 1,4 +WMBP: (0-1),(1-30)
  • Page 88: Keypad Enable/Disable +Wpad

    Note: Display valid parameter range. AT+WPAD? Note: Display current setting. AT+WPAD=0 AT&W Note: Disable keypad and write to NV. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 13 – Specific AT Commands Possible Responses +WPAD (0-1) +WPAD: 1 Note: Keypad enabled.
  • Page 89: Chapter 14 - Sim Toolkit For Ruim Software Version

    SIM Application which menu item is selected. The commands used for this operation are: +STIN (SIM Toolkit Indication) +STGI (SIM Toolkit Get Information) +STGR (SIM Toolkit Give Response) Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 14 – SIM ToolKit...
  • Page 90: Messages Exchanged During A Sim Toolkit Operation

    The +STCR (SIM Toolkit Control response) indication is an unsolicited result sent by the SIM when call control functionality is activated and before the customer application has performed any outgoing call, SMS, SS, or USSD. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) STEP 1: Configuration and Activation...
  • Page 91: Sim Toolkit Set Facilities +Stsf

    AT+CPIN? +CPIN: SIM PIN AT+CPIN=0000 OK PIN Ok +WIND: 4 AT+STSF? +STSF: 1,”5FFFFFFF7F”,3 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +CME ERROR: <err> +STSF: <Mode>,<Config>,<Timeout>,<Autoresponse> Enable the reporting of mobile equipment errors Set indications Query ME Status ME is ready.
  • Page 92: Sim Toolkit Indication +Stin

    Menu. AT+STIN? Note: Ask for the last SIM toolkit indication sent by the SIM. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 14 – SIM ToolKit Possible Responses +STIN: 0 Note: the last SIM toolkit indication was a Setup Menu...
  • Page 93: Sim Toolkit Get Information +Stgi

    Get information about ‘Send USSD’ pro-active command Get information about ‘SETUP EVENT LIST’ pro-active command. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses See following table. +CME ERROR: <err> +STGI: (0-11) Possible Responses +STGI: <Alpha Identifier menu>...
  • Page 94 Values when Cmd=4 (Setup Call ) <Type> <CalledNb> <SubAdress> <Class> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Menu item Identifier Number of items in the main menu Alpha identifier label of items in ASCII format No help information available Help information available Contains a pro-active command identifier.
  • Page 95 Text String containing 0x00 0x41, the text displayed is .0041. Error Codes: + CME ERROR: 3 +CME ERROR: 4 +CME ERROR: 518 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Tone Dial Tone Busy Tone Congestion Tone Radio ack...
  • Page 96: Unsolicited Result: Sim Toolkit Control Response +Stcr)

    BEYOND CAPABILITIES UNABLE TO PROCESS NO RESPONSE END SESSION Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable the reporting of mobile equipment errors Set indications SIM ToolKit functionality activated with all facilities. The main menu has been sent from the SIM.
  • Page 97 +STIN: 0 indication, not after a +STGI=0 request. All of the Terminal Responses are not possible with all of the Proactive Commands. If a Terminal Response is attempted during an incompatible Proactive Command session, a +CME ERROR: 3 will be returned. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 14 – SIM ToolKit...
  • Page 98 +STGI: 9,1,1 +STIN: 1 AT+STGI=1 +STGI: 0,” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Operation not allowed. This error is returned when a wrong parameter is detected. Operation not supported. This error is returned when the user gives a response with SIM ToolKit functionality not activated.
  • Page 99: Chapter 15 - Provisioning At Commands

    Some parameters or commands discussed in this chapter may be re-defined by your network carrier. Your carrier will provide these commands for you. See also the printed Activation Notices that accompany the Multi-Tech wireless products. What is Provisioning?
  • Page 100: Service Programming Code +Wspc

    AT+WIMI=310008585551212 Note: Set IMSI to 310008585551212 For RUIM software releases, this command is not valid and will return “Error 3”. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible Responses ERROR Note: Invalid request...
  • Page 101: Sid And Nid +Wsid

    AT+WSCI? Note: Read the current slot cycle index AT+WSCI=1 Note: Set the slot cycle index Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible Responses +WSID: 1, 45, 84 Note: The SID/NID pair 45,84 in location 1 is selected.
  • Page 102: Primary Browser Gateway +Wbgp

    Command syntax: AT+WPCC=<channel a number>,<channel b number> Syntax: Command AT+WPCC? Note: Get current primary CDMA channels AT+WPCC=211,432 Note: Set the primary CDMA channels Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WBGP: 127,0,0,1 Possible Responses +WBGS: 127,0,0,1 Possible Responses +WPDS: ”#777”...
  • Page 103: Secondary Cdma Channels +Wscc

    Note: Get the Service Options of the current NAM AT+WSOM=1,4,2,2 Note: Set current NAM Service Options Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible responses +WPCC: 691,777 Possible Responses +WSOM: 0, 1, 2, 0...
  • Page 104: Commit Changes +Wcmt

    AT+WSNR? Note: Show last read SID/NID list index. Default: 0. AT+WSNR=? Note: Show SID/NID list index range. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible Responses Note: software reset is performed Possible Responses ERROR Note: Service provisioning code not yet entered.
  • Page 105: Download Prl +Dprl

    Note: Activate new Nam2 PRL. AT+DPRL=? Note: Display parameter ranges. AT+DPRL? Note: Display last used parameter values. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Possible responses Note: Code successfully entered. Note: PRL stored in module.
  • Page 106: Service Programming Example

    Note: Set mobile directory number to 8585551212 AT+WCMT=1 Note: Commit all changes performed during this provisioning AT session to non-volatile memory. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 15 – Provisioning AT Commands Response ERROR Note: Service Programming code not yet entered...
  • Page 107: Chapter 16 - Extended At Commands In Is707.3

    Chapter 16 – Extended AT Commands in IS707.3 Multi-Tech CDMA modem also implements the CDMA AT commands as specified in the TIA/EIA/IS-707.3. Refer to IS707.3 for more information about these commands (range, parameter definition, result codes, etc.). Note: Some of the AT commands may not be supported by the network; please verify with your carrier as to its support of IS707.3 commands.
  • Page 108: Select Pulse Dialing P

    Value 255: disable carrier detect ATS11? Note: DTMF tone duration and spacing in milliseconds (value: 50-255) Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses Note: Command is valid Possible Responses...
  • Page 109: Error Control Operation +Eb

    Command AT+ER? Note: Display the current setting. AT+ER=1 Note: Set value to 1. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +EB: 1,0,30 Note: This is the default setting...
  • Page 110: Error Control Selection +Es

    Command AT+ESR? Note: Display the current setting. AT+ESR=1 Note: Set value to 1. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +ES: 3, 0, 2 Note: Command is valid...
  • Page 111: Error Control Selection +Etbm

    Command AT+GMM? Note: Display the current setting. AT+GMM Note: Display the model Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +ETBM: 0, 1, 20 Note: Command is valid Note: Command is valid...
  • Page 112: Request Revision Identification +Gmr

    AT+GOI Note: Display the responses to the command Currently, no information text is provided. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses ERROR Note: Command is not valid +GMR: S/W VER: WISMOQ WQ1.8, 10015...
  • Page 113: Modulation Selection +Ms

    Note: Display the current setting. AT+MR=? Note: Display the range of setting. AT+MR=1 Note: Enable reporting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +MS: V32B,1,1200,14400 Note: Command is valid...
  • Page 114: Reporting Control +Mv18R

    Note: Display the current setting. AT+MV18S=1,1,1 Note: Set mode value to 1. AT+MV18S? Note: Display the current setting. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +MV18R: 0 Note: Command is valid...
  • Page 115: Cellular Extension +Cxt

    AT+CAD=? Note: Display the available service values. This is a read-only command. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CXT: 0 Note: Command is valid +CXT: (0-1)
  • Page 116: U Interface Data Compression Reporting +Cdr

    Note: Set to 1. This default value for the +CRM parameter shall be 0 if this value is supported by the DCE. Note: Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses...
  • Page 117: Battery Charge +Cbc

    AT+CMIP? Note: Display the current setting AT+CMIP? Note: Display the current setting AT+CMIP Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CBC: 0, 77 Note: Command is valid ERROR...
  • Page 118: Base Station Ip Address +Cbip

    Command AT+CSS? Note: Display the current setting. AT+CSS=? Note: Display the parameter range. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CBIP: 198.229.142.65 Note: Command is valid Note: No IP address assigned.
  • Page 119: Select Multiplex Option +Cmux

    Command AT+CHV Note: Display the current setting. AT+CHV0 Note: Hang up the call. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses +CMUX: C, 2 Note: Command is valid +CMUX: (1-9,A-D,F), (1,2)
  • Page 120: Dial Command For Voice Calls +Cdv

    Note: Display the current setting. AT+CTA=? Note: Display valid parameter range. AT+CTA=1 Note: Set to one second. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 16 – Extended AT Commands in IS707.3 Possible Responses ERROR Note: Command is not valid...
  • Page 121: Chapter 17 - Fax Parameters

    +FPI: "Polling station IDd" +FPS +FPS:<value> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Fax Connection. The +FCO response indicates that a connection has been made with a Group 3 facsimile station. DCS Frame Information. Reports negotiated parameters; sent after +FDT or +FDR execution but before the CONNECT result code.
  • Page 122: Fax Parameters

    +FCR AT+FCR=<0|1> +FIE AT+FIE=<0|1> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Post Page Message. The +FET: response is generated by a receiving facsimile DCE after the receipt of Phase C data and post-page message from the transmitting station when in data reception mode (+FDR).
  • Page 123 +FBO AT+FBO=<0|1> +FLO AT+FLO=<value> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Copy Quality Checking. The +FCQ command controls the copy quality checking and correction. The sub-parameters control the copy quality checking and correction of data sent to the remote side.
  • Page 124: Fax Session Sub-Parameters

    Page Width Page Length Data Compression Error Correction File Transfer Scan Time/Line Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Values 00 = Normal 98 lpi 01 = Fine 196 lpi 0 = 2400 bps 1 = 4800 bps...
  • Page 125: Chapter 18 - Qualcomm Defined At Commands For Cdma Operation

    Command AT$QCPREV? Note: Display the current setting AT$QCPREV Note: Display the of value Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses Note: Command is valid Possible Responses...
  • Page 126: Originate M-To-M Packet Data Call $Qcmtom

    Command AT$QCPPPD? Note: Display the current setting AT$QCPPPD Note: Dump PPP statistics information Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMTOM: “” Note: Command is valid...
  • Page 127: Reset Ppp Protocol Statistics $Qcpppr

    Command AT$QCUDPR? Note: Display the current setting AT$QCUDPR Note: Reset UDP statistics counter Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses ERROR Note: Command is not valid...
  • Page 128: Dump Tcp Protocol Statistics $Qctcpd

    AT$QCCLR? Note: Display the current setting AT$QCCLR Note: Clear the mobile error log Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses ERROR Note: Command is not valid...
  • Page 129: Answer Incoming Voice Call $Qccav

    AT$QCDMR=? Note: Display the range of values AT$QCDMR=115200 Note: Set DM baud rate to 115200 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses +WCNT: 3 Note: Command is valid...
  • Page 130: Set Medium Data Rate $Qcmdr

    AT$QCSCRM =? Note: Display the range of values AT$QCSCRM =0 Note: Set value to 0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMDR: 3 Note: Command is valid...
  • Page 131: R-Sch Throttling Selection $Qctrtl

    AT$QCMIP=? Note: Display the range of values AT$QCMIP=0 Note: Set value to 0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCTRTL: 1 Note: Command is valid...
  • Page 132: Mip Selection $Qcmipp

    AT$QCMIPEP=? Note: Display the range of values AT$QCMIPEP=0 Note: Set value to 0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPP: 0 Note: User profile 1 is currently used...
  • Page 133: Return Profile Information $Qcmipgetp

    AT$QCMIPRT=? Note: Display the range of values AT$QCMIPRT=1,1 Note: Set value to 1 and commit Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses ERROR Note: Command is not valid...
  • Page 134: Set Mn-Aaa Shared Secrets In Active Profile $Qcmipmass

    AT$QCMIPMASSX=? Note: Display the range of values AT$QCMIPMASSX=FF,0 Note: Set value to 0xFF, but not commit Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPMASS: Set Note: Command is valid...
  • Page 135: Set Mn-Ha Shared Secrets In Hex Active Profile $Qcmipmhssx

    AT$QCMIPMHSPI=? Note: Display the range of values AT$QCMIPMHSPI=5500,0 Note: Set value to 5500, but not commit Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPMHSSX: Set Note: Command is valid...
  • Page 136: Set Primary Ha Ip Address $Qcmippha

    Note: Display the range of values. AT$QCMIPHA =10.1.2.15,1 Note: Set to 10.1.2.15, and commit to NV. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 18 – Qualcomm Defined AT Commands for CDMA Operation Possible Responses $QCMIPPHA: 10.1.1.20, 0 $QCMIPPHA: ((0-255).(0-255).(0-255).(0-255)),(0-1)
  • Page 137: Chapter 19 - Tcp/Ip App At Commands

    A number of standard AT commands are not available when the TCP App feature is in use; that is, a AT+WPPP session has been successfully started. See Chapter 20 for a list of these restricted AT commands. The ERROR result will be returned in their attempted use. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Commands Description...
  • Page 138: Start/End Ppp Connection +Wppp

    <port> range 0 to 65535. Response Values <type> <socket> The socket number of the potential connection. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands Possible responses +WPPP:201 (negotiating) +WPPP:200 (connected) Note: PPP session started.
  • Page 139: Close Socket +Wcsk

    ERROR return will occur after the AT+WTMO specified time value (default 500 milliseconds). Partial payload data for a timed out AT+WSTX command will be discarded. Values: <type> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands Possible responses +WOSK: 0,0 +WSKS: 0,0,1 Note: TCP socket zero is open.
  • Page 140: Read Receive Data +Wsrx

    Note: Read the pending UDP data. AT+WSRX? Note: Show last used command parameters. AT+WSRX=? Note: Display command parameter ranges. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands Possible responses +WSTX: 0,0,4 Note: Payload transmitted.
  • Page 141: Display Connection Status +Wgss

    Note: Display command parameter ranges. AT+WTMO=1000 Note: Set timeout value to 1 second. AT+WTMO? Note: Show configured timeout value. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands Possible responses +WGSS: (0-1) Note: Parameter ranges displayed.
  • Page 142: Configure Receive Data Mode +Wcrx

    Values: Command syntax: AT+WFDM Syntax: Command AT+WFDM Note: Force module into dormant mode. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands Possible responses +WCRX: (0-1),(0-1) Note: Parameter ranges displayed. Note: Command accepted.
  • Page 143: Ip Address Lookup +Wdns

    +WPPP: 200 Note: PPP Session established and available. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) The domain name string to lookup. The quotes around the name are required. The same domain name must be specified in the second command.
  • Page 144: Socket State Change +Wsks

    Response syntax: +WSTX: <type>,<socket>,<length> Syntax: Possible responses +WSTX: 0,0,536 Note: 536 bytes sent on TCP socket zero. +WSTX: 1,1,600 Note: 600 bytes sent on UDP socket one. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands...
  • Page 145: Socket Data Transmission Error +Wste

    Response syntax: +WSRE: <type>,<socket>,<error> Syntax: Possible responses +WSRE: 0,0,119 Note: Broken pipe for TCP socket zero. +WSRE: 1,1,117 Note: Connection reset on UDP socket one. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 19 – TCP/IP App AT Commands...
  • Page 146: Dormant Mode Status Change +Wdor

    Response syntax: Possible responses +WDNS: 0 Note: DNS lookup step one complete. +WDNS: 213.41.30.26 Note: DNS lookup step two complete. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +WDNS: <status> +WDNS: <ip address> Chapter 19 – TCP/IP App AT Commands...
  • Page 147: Chapter 20 - Reference Information

    Invalid PD parameter PD parameter not supported Tracking mode requires +WPDFR setup No active session Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Information Chapter 20 – Reference Information Resulting from the following commands All GSM 07.07 commands (+CME ERROR: 3) All GSM 07.07 commands (+CME ERROR: 4)
  • Page 148: Message Service Failure Result Code: +Cms Error:

    Invalid Parameter Operation only allowed during an incoming call Invalid Mode Selection Invalid Roam Selection Invalid Band Selection Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information Resulting from the Following Commands +WPPP +WSTX +CMGS, +CMSS All SMS commands (+CMSS, +CMGL, +CPMS…...
  • Page 149: Final Result Codes

    CONNECT 2400 CONNECT 4800 CONNECT 9600 CONNECT 14400 +CSSI: <code1>[,<index>] As verbose Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information Description Error from GSM 07.05 commands Error from SMS commands (07.07) Busy signal detected...
  • Page 150: Gpsone Error Result Code: +Wpder:

    Bad privacy parameter Bad download parameter Bad net access parameter Bad operation parameter Bad number of fixes parameter Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information <code> Description Wrong server Information parameters Error in timeout parameter...
  • Page 151: Parameters Storage

    Specific AT Commands +ADC +CMER +CPHS +W32K +WCCS +WCDM +WPAD +WRIM +WSVG Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Immediate Save AT&F (n,0 mode) 115200 Chapter 20 – Reference Information Default Values 0: disable CDMA RUIM: 0xC9; TE:0xC8...
  • Page 152: Codes For Sms Status Report (+Cds And +Cmgr)

    32769 32770 32771 32772 32773 32774 32775 32776 32777 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Meaning Address vacant Address translation failure Network resource shortage Network failure Invalid Teleservice id Other Network Problem No page response Destination busy...
  • Page 153: At Commands Supported When Sim Card Removed

    ATIx +IPR +CNUM +CGSN +CMEE +WPRL +CPOF +CFUN Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Note and Explanation Set modem fixed baud rate Display the error code Clock management Battery charge General status indication Set modem local echo...
  • Page 154: Tcp App Socket Status Events

    Description PPP established and available PPP initialization in progress PPP closed or unavailable PPP is closing Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Description Socket is open Receive data is available Socket is closed Chapter 20 – Reference Information...
  • Page 155: Tcp App Restricted At Commands

    +WVSS Verizon system selection AT&F Reset to factory defaults Answer call Call origination ATDL Call origination using last entered number Call termination Reset to default configuration Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information...
  • Page 156: Phonebook Ucs2 Unicode

    Octet 5 contains a value with bit 7 equal to zero. Bits 6 through 0 (010 1101) of this octet correspond to the character dash ‘ - ‘. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Octet 4 Octet 5...
  • Page 157: Commands Over Dm Port (Muxlite)

    HDLC packets between the two +CMGS packets. AT+CMGD Delete SMS message AT+CCED Cell environment AT+CREG Registration and roaming Unsolicited Messages General unsolicited status or indication messages from the module. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 20 – Reference Information...
  • Page 158 AT+CSQ? +CME ERROR: 3 AT+CLCC +CLCC: 0,9,0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable detailed reporting of mobile equipment errors. Host application configured for PPP dial up access. Initiate a data call. Number string is carrier specific.
  • Page 159: Chapter 21 - Unsolicited At Result Codes

    Refer to the +CCED AT command in Chapter 13 for more information and a definition of the returned values. Response syntax: +CCED: <requested dump> Syntax: Example Result +CCED: 1,725,4,65535,6,,0,,,-104,-35,-63 Note: Cell environment description indication in response to AT+CCED=0,1 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Result Codes Chapter 21 – Unsolicited AT Result Codes...
  • Page 160: Call Waiting Indication +Ccwa

    Response syntax: +CKEV: <key>,<press> Syntax: Example Result +CKEV: 9,0 Note: Indicates key 9 has been released Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Interface Data Compression) for an explanation of +CDS memory.
  • Page 161: Caller Id Presentation +Clip

    3 – Emergency Response syntax: +CMTI: <mem>,<index>,<priority> Syntax: Example Result +CMTI: “MT”,5 Note: Normal priority incoming message received and stored in “MT” memory at index 5 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes...
  • Page 162: Mode Preference +Cops

    TEST markov, loopback, or test call UNKNOWN unknown/undefined call type Response syntax: +CRING: <Type> Syntax: Example Result +CRING:VOICE Note: Incoming normal voice call. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes...
  • Page 163: Rxlev Indication +Csq

    (only available on networks supporting answering supervision for payphone applications) Response syntax: +WANS:<call type> Syntax: Command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Possible Responses +RING +WANS:0...
  • Page 164: Call Connected +Wcnt

    This response displays a broadcast message that the carrier may send to all mobiles in an emergency. This Description: event is required for CDMA specifications. Response Syntax: +WFNM=”<message>” Syntax: Command Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Possible Responses +WORG:18005551212 +WCNT:3 Note: Call Connected with service option 3...
  • Page 165: Flash Indication +Wfsh

    AT+WIND? Note: Show current setting. AT+WIND=? Note: Show <IndLevel> range. AT+WIND=128 Note: Turn on Network lost indication only. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WFSH R-UIM Presence Reserved Reserved Indication that the product is ready to process all AT commands...
  • Page 166: Call Originated +Worg

    Reserved for Standard Enhanced Roaming Indicator Numbers 13 - 63: Reserved for Non-Standard Enhanced Roaming Indicator Numbers 64 - 127: 128 - 255: Reserved Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WORG:18005551212 +WCNT:3 Possible Responses +WPRV: 1...
  • Page 167: Emergency Mode +Wsos

    Syntax: Command <nam> NAM 1 NAM 2 NAM 3 NAM 4 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WSOS:1 +WORG:911 Note: Unsolicited +WSOS result confirms Emergency Mode is entered +WSOS:0 Note: Unsolicited +WSOS result confirms Emergency...
  • Page 168: Voice Mail Indicator +Wvmi

    Note: Display current power mode state. <state> Leaving power save Entering power save Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Possible Responses +WVMI: 1,2 Note: 2 messages are in your voicemail box. Interrogate the status of CPHS functionality...
  • Page 169: Position Determination Start Session Result +1

    <velocity vertical> 8-bit signed integer. This value is the vertical speed in units of 0.5 meters per second. The value is in the range 0 to 255 (-64 to +63.5 meters per second). Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +WPDSS: <latitude>,<longitude>,<timestamp>,<position uncertainty angle>, <axis...
  • Page 170: Position Determination Error +Wpder

    Bad privacy parameter Bad download parameter Bad net access parameter Bad operation parameter Bad number of fixes parameter Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes Value Uncertainty in Meters 1024 1536...
  • Page 171: Gpsone Session Prompt +Wpust

    PRL using the AT command interface. Response Syntax: +DPRL: <status> Syntax: Example Result +DPRL: 0 Note: Downloaded PRL validation successful. <status> Validation successful Validation unsuccessful Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 21 – Unsolicited AT Result Codes...
  • Page 172: Chapter 22 - At Command Examples

    AT+CLIR=0 ATD18001234567; +WORG:18001234567 +WCNT:3 ...Conversation +WEND:10 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Examples Display module manufacturer Display module hardware revision information MSM 6050 chipset, hardware version not set Display module software revision information WZ2.04V May 05 2004 15:43:21...
  • Page 173: Call Waiting

    PPP session shutdown. For a broken data pipe situation, the “+++” command can be used to force the module back into command mode. NO CARRIER Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable incoming caller id presentation Display module phone number...
  • Page 174: Short Message Examples

    AT+CMGR=1 +CMGR:"REC UNREAD","8585552222","02/05/15,15 :54 :04",1,2,0,”5550000”,15 Test message #2 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) SMS-DELIVER stored in NV, SMS-STATUS-REPORT routed to TE New message received and stored in “MT” memory at index 0 SMS-DELIVER routed to TE Received message.
  • Page 175: Gpsone Examples

    AT+WPDDD=0,10 AT+WPDST=3 AT+WPDSS=“PVH”,60,50 +WPDSS:#,#,#,#,#,#,1,7,#,#,#,#,# < end loop> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Session type is single-shot Accuracy optimal operation mode Display privacy setting Privacy is set to allow all Set gpsOne transport level (DBM); carrier specific capability...
  • Page 176: Fax Examples

    … Transmission of page data … 0x10 0x03 AT+FET=2 +FPS:<status> +FHS:<status> NO CARRIER Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable extended result codes Select fax class 2 Set flow control Set identifier string Set message reporting Set capability to receive...
  • Page 177 AT+WCSK=0,1 +WSKS: 0,1,4 AT+WGSS=0 +WGSS: 0,2,1,2,0,0,0 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Enable detailed reporting of mobile equipment errors. Display TCP connection status. TCP status, PPPstate “closed”, RxMode “Unsolicited”, All sockets “closed”. Set TCP receive mode; polled received data.
  • Page 178 … +WSKS: 1,0,1 AT+WSTX=1,0,500,<data> +WSTX: 0,500 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Set UDP receive mode; unsolicited received data. Start a SIP data call and open a PPP session. Unsolicited response; PPP session startup in progress. Unsolicited response; PPP session established and available.
  • Page 179 AT+WOSK=1,216,37,68,117,250 +WOSK: 1,0 +WSKS: 1,0,1 … Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Other +WSTX commands and +WSTX responses for data transfers. Send 500 bytes of data on UDP socket zero. Lost UDP socket zero connection. Display UDP connection status.
  • Page 180: Chapter 23 - Verizon® Specific At Commands

    <data> (text mode) Example Result +CMT: “123456”,”98/10/01,12 :3000+00”,129,1,2,0,”5550000”,5<CR><LF> Hello Note: Incoming message received Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Message type indicator Status report MO delivery acknowledge message Message Reference Recipient Address Type-of-Address of <ra>...
  • Page 181: Roaming Indication +Wrom

    <text> Command Note: Example of acquiring service with enhanced roaming. Note: Example of acquiring service without enhanced roaming. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Bit Length Character Encoding Octet, unspecified see IS-91 IS-91 Extended Protocol Message 7-bit ASCII (ANSI x3.4)
  • Page 182: Emergency Mode +Wsos

    Urgent Emergency <privacy> Message privacy: Normal Restricted Confidential Secret Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WSOS:1 +WORG:911 Note: Unsolicited +WSOS result confirms Emergency Mode is entered +WSOS:0 Note: Unsolicited +WSOS result confirms Emergency Mode is exited...
  • Page 183: List Message +Cmgl

    <lang> <encod> Encoding <length> Length of the text message (in bytes). Message text <data> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +CMTI: “MT”,1 Note: New message received +CMGR: “REC UNREAD”,”8585551212”, ”98/10/01,18 :22 :11+00”,1,2,0,0,0,”8585550000”,9<CR><LF>...
  • Page 184: Send Message +Cmgs

    Note: Send a message with the specified priority, privacy, reply option and call back number. Notice length field is omitted. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +CMGL: 1,”REC UNREAD”,”8585551212”,1,2,15...
  • Page 185: Write Message To Memory +Cmgw

    AT+WSPC=1,111111 Note: Enter service programming code 111111 AT+WSPC=1,000000 Note: Enter service programming code 000000 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +CMGW: 4 Note: Message stored in index 4 +CMGW: <index>...
  • Page 186: Verizon® System Selection +Wvss

    This response will be accompanied by three quick audio tones from the speaker. Response Syntax: +WOT3: “Programming Unsuccessful” Syntax: Possible Responses +WOT3: “Programming Unsuccessful” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WVSS: (0-3) +WVSS: 1 Note: Home only mode set.
  • Page 187: Commit Successful +Wotc

    Response Syntax: +WLCK: “Excess SPC failures!” Syntax: Command AT+WSPC=0,123456 Note: 15 attempt to enter the SPC. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WLCK: “Excess SPC failures!” Note: Modem now in offline mode.
  • Page 188: Position Determination Lock Level +Wplck

    Note: Display valid parameter range AT+WPLCK? Note: Request current setting type AT+WPLCK=3 Note: Select lock all Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 23 – Verizon® Specific AT Commands Possible Responses +WPLCK: (0-3) +WPLCK: 0 Note: Command successful...
  • Page 189: Chapter 24 - Sprint® Specific At Commands

    Note: Ask for current functionality level AT+CFUN=0 Note: Set phone offline AT+CFUN=1 Note: Set phone ONLINE. A software reset is performed. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Message type indicator Status report MO delivery acknowledge message Message Reference Recipient Address Type-of-Address of <ra>...
  • Page 190: Signal Quality +Csq

    Note: Bar Incoming Calls AT+CLCK=”AO”,9 Note: Query outgoing call barring status Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Note: <raw rssi>, <raw Ec/lo>, and <fer> as defined above BAOC (Bar Outgoing Calls) Allow all outgoing calls Allow outgoing calls only for phonebook entries (use ATD> command) and emergency...
  • Page 191: Mobile Directory Number +Wmdn

    (Base Station Protocol Revision In Use – Band Class 1/PCS) <BS_P_REV> J-STD-008C IS-95B IS-2000 IS-2000A 0 – Max RF Channel Number <CHANNEL> Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Possible Responses +WMDN: 8581111111...
  • Page 192: Packet Zone Identifier +Pzid

    AT+WDPXY=68.28.31.1 Note: Set the proxy server address value. AT+ WDPXY =”” Note: Set invalid address value. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Possible Responses +CSS: 2, A, 4145, 6, 334...
  • Page 193: Wiota Connection Control +Wiota

    Response Syntax: +WOAR: “Please Retry” Syntax: Possible Responses +WOAR: “Please Retry” Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Possible responses +WIOTA: (0-5) Note: Session started. +WIOTA: 1...
  • Page 194: Display Pri Checksum +Wsum

    Syntax: Command AT+WRMM Note: Reset MIN and MDN to factory defaults. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Possible Responses +WSUM: 0004DDCF Note: The displayed value is a eight digit hexadecimal number.
  • Page 195: Iota Feature Application Note

    If the IOTA provisioning session fails, the unsolicited response +WOEA: "IOTA error 1012" will be displayed. Verify that configuration parameter values have been properly entered and that appropriate PRI data is being used. Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Chapter 24 – Sprint® Specific AT Commands Value http://hcmci.iota.spcsdns.net:8080/ciip...
  • Page 196: Index

    &D Data Terminal Ready Signal ...60 &F Restore Factory Setting ...62 &S Data Set Ready Signal ...60 &T Audio Loopback ...61 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Index &V Display Configuration ...61 &W Save Configuration...62 + WSID SID and NID...101 +ADC Analog Digital Converters Measurements ...77...
  • Page 197 +SIDET Side Tone Modification ...28 +SPEAKER Speaker & Microphone Selection ...27 +STCR Unsolicited Result SIM ...96 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +STGI SIM ToolKit Get Information ...93 +STGR SIM ToolKit Give Response ...96 +STIN SIM ToolKit Indication ...92 +STSF SIM ToolKit Set Facilities ...91...
  • Page 198 +WTMO Configure Socket Transmit Timeout...141 +WTMR View Modem Timers ...19 +WTONE Play Tone...78 +WTTY TTY Mode ...28 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) +WUSS Change SMS Status...49 +WVMI Voice Mail Indicator ...168 +WVSS Verizon® System Selection ...186 2G ...10...
  • Page 199 Examples of General AT Command Usage ...172 Excess SPC Failures +WLCK ...187 Extended AT Commands ...107 Extended Error Report +CEER ...22 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Extended Error Report (+CEER) Call Processing Codes ...148 Extended Roam Indicators +WRMW ...34 Facility Lock +CLCK...37, 190...
  • Page 200 OTKSL ...100 P Select Pulse Dialing ...108 Packet Dial String +WPDS ...102 Packet Zone Identifier +PZID ...192 Parameters Storage ...151 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Passwords ...35 PD ...11 PDU ...11 Personal Identification Number ...35 Phone Activity Status +CPAS ...16 Phone Offline +CPOF ...16...
  • Page 201 Set IMSI +WIMI ...100 Set Medium Data Rate $QCMDR ...130 Set MN-AAA Shared Secrets in Active Profile $QCMIPMASPI...135 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) Set MN-HA Shared Secrets in Active Profile $QCMIPMHSPI ...135 Set NAI for Active Profile $QCMIPNAI ...133 Set Phone Functionality +CFUN ...189...
  • Page 202 V DCE Response Format...61 V.18 Reporting Control +MV18R...114 V.18 Selection +MV18S ...114 V.42...109 V24-V25 ...12 Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J) V42...12 Verizon® Specific AT Commands ...180 Verizon® System Selection +WVSS ...186 View Modem Timers +WTMR ...19 Voice Mail Indicator +WVMI ...168...

Table of Contents