sure and adjust the media advance as needed until the pat-
tern is exactly 34 inches (900 mm) long.
10-inch (250 mm) calibration — prints a 10-inch (or 250
mm) test pattern so you can verify its length with an accurate
metal ruler. This is not as precise as the 34-inch (900 mm)
calibration, but it uses less media. Measure and adjust the
media advance as needed until the pattern is exactly 10
inches (250 mm) long.
Fig. 4-2. Measure between the calibration marks
Input MFN — enter the Media Feed Number that was dis-
played after a previous media feed calibration, to return to
that setting without performing the calibration again.