Msi Feeder Assy Removal/Installation; Msi Retard Pad Replacement - Xerox 5915 Service Manual

Table of Contents

Advertisement

4-4
2.2.1 MSI Feeder Assy
Removal/Installation
Removal
1. WARNING: Power off the machine and
disconnect the power cord.
2. Open the Rear Upper Cover.
3. Open the Right Upper Cover.
4. (Figs. 1 & 2): Remove the MSI Tray.
. Open MSI Tray.
. Remove Screw and then open MSI Tray
slide it toward rear and remove it.
1
2
(Fig. 1)
5. Open the Right Transport Cover.
6. (Fig. 2): Remove the MSI Feeder Assembly.
. Disconnect P/J616 and P/J210 .
. Remove Screw.
. Remove MSI Feeder Assembly.
1
3
2
(Fig. 2)
Installation
1. Perform the installation in the reverse order of
removal.
Section 4 Disassembly/Assembly/Adjustment

2.2.2 MSI Retard Pad Replacement

NOTE: • You should replace the Retard Pad, the
Feed Roller(2.3.2).
• You should clear the Feed Counter in
Diag. Mode [30-4].
Removal
1. WARNING: Power off the machine and
disconnect the power cord.
2. Remove the MSI Feeder Assembly ..... (2.2.1)
3. (Fig.1): Remove the Tie Plate Assembly.
. Remove Screws (2).
. Remove Tie Plate Assembly.
1
(Fig. 1)
2. Paper Handling
4. (Fig. 2): Remove the Retard Pad.
. Turn over Tie Plate Assy.
. Release locking of the Retard Pad.
==
=
(Fig. 2)
. Remove Retard Pad.
3
(Fig. 3)
Installation
1. Perform the installation in the reverse order of
removal.

Advertisement