2-6
Output Check
Function:
This operates parts such as the Solenoid, the
Clutch and the Motor. You can set parts within
the same Chain to the ON positions
simultaneously.
Procedure:
1. Enter Diagnostic(C/E) Mode.
2. Enter the Chain Code for a part to be
operated. Press the Start button.
3. Enter the Function Code and press the Start
button.
• The designated part starts operating.
4. When you operate parts simultaneously,
enter the Function Codes for the parts you
will operate successively. Press the Start
button.
5. When you stop operating a part
simultaneously, press the Stop Clear
button.
• When parts are operating, stop them
simultaneously.
• The following parts stop automatically after
respective specified periods of time:
• All Solenoids/Clutches ..... 1 sec.
• Lamp Carriage Motor ....... 1 sec.
• Exposure Lamp ................ 30 sec.
REF.: When you press the Start button
again after the above parts stop
automatically, they start operating
again.