2.7.1 Registration Assy
Removal/Installation
Removal
1. Power off the machine and disconnect the
Power Plug.
2. Remove the Drum Unit and place a black
bag over it ...................................... (5.1.1)
3. Remove the Deve. Unit. ................... (6.2.1)
4. Remove the TC/DTC Assy.
5. Remove the following Covers:
• Right Upper Cover
• Rear Upper Cover
• Rear Lower Cover
6. Remove the MSI Feeder Assy. ......... (2.2.1)
7. (Fig. 1): Remove the Upper Chute Assy.
. Loosen Screw and remove Chute Bias
resistance.
. Remove Spring.
. Open Registration Assy pin-installed
bracket.
. Remove Upper Chute Assy.
(Fig. 1)
8. (Fig. 2): Remove the Registration Assy.
. Disconnect P/J116 (for Regi-Sensor) &
P/J214 (for Regi-Gate Solenoid).
. Remove Screws(2).
. Remove Registration Assy.
1
2
3
(Fig. 2)
Installation
1. Reinstall the Registration Assy by reversing
Step 8, Removal.
2. Restore the machine to its original state in the
reverse order of the removal.
Section 4 Disassembly/Assembly/Adjustment
2.7.2 Registration Gate Solenoid
Replacement

2.7.3 Regi-Gate Sensor Replacement

• Replace both by removing the Registration
Assy.................................................. (2.7.1)
• The Solenoid/Sensor can now be replaced.
2. Paper Handling

2.7.4 Registration Roller Replacement

Removal
1. Power off the machine and disconnect the
Power Plug.
2. Remove the Registration Assembly ..... (2.7.1)
3. Remove the Registration Roller.
. (Fig.1): Remove E Clip and then Bearing.
(Fig. 1)
. (Fig.2): Remove Screw and then Gear.
(Fig. 2)