● Bring the needle to b.d.c.
● Fit screw clamp 1 ( Part no. 61-111 600-35/001 ) to needle bar 2.
● Bring 2.4 mm needle rise gauge ( Part no. 61-111 600-09 ) between the screw
clamp 1 and the guide stop of the needle bar 2.
● Loosen the screw clamp 1, slide up as far as possible and tighten it again.
● Remove the needle rise gauge.
● Turn the balance wheel in the direction of sewing until screw clamp 1 has contact.
● Turn hook sleeve 3 ( screws 4 ) according to requirement 1 and adjust it according to
requirement 2.
● Loosen and remove screw clamp 1.
The machine remains switched on for the next adjustment.
Adjustment
13 - 36