13
Upper knife stop
.23
Requirement
When the adjustment gauge 1 is resting on the needle plate insert, the arm of the knife
should be touching the upper knife stop.
Fig. 13 - 19
● Fit adjustment gauge 1 ( Part no. 61-11 635-93 ).
● Turn stop screw 2 ( screw 3 ) according to the requirement.
● Remove adjustment gauge 1.
1
56-042a
56-042
Adjustment
2
3
13 - 22