Restoring factory defaults

Light sequence:
Ready / Data—On
Error—On
Message:
Printer is resetting to the original factory default settings.
Solution:
Press and hold
to reset printer.
C
artridge region mismatch
Light sequence:
Error—On
Secondary light sequence:
Press
twice quickly to see the secondary light
sequence.
Ready / Data—Blinks four times
Message:
The toner cartridge being used is not programmed for the specific
region.
Solution:
Remove the toner cartridge, and install a new toner cartridge that is programmed for the same region as your
printer. See the back of the printer for a label with your printer region location. See Ordering supplies on page 66
for a list of correct supplies and part numbers.
Using the operator panels