Download Print this page

SCAN DSA 5 Instructions For Installation And Use page 4

Freestanding + built-in

Advertisement

Warranty conditions
All SCAN wood-burning stoves and inserts are made of first-class material and are
subject to a strict quality control before they leave the factory. However, if an error
should occur, we back all SCAN wood-burning stoves and inserts with an extensive,
five-year limited warranty.
See also the General Instructions for Installation delivered with your insert for more
details.
Technical info and measures:
Emission (% CO at 13% O 2 ) :
Efficiency:
Thermal output:
Min./Max.
Weight DSA 5, built-in/freestanding:
Recommended fuel:
Charge:
DSA 5 free-standing
1650
774
Ø179
243
DSA 5 built-in
714
Scan DSA 5
0,11%
77%
8 kW
8-10 kW
172 kg / 210 kg
Wood
2,7 kg
1374
Min. distance to the cei-
ling: 250 mm
617
1540
1374
588
Scan A/S - DK-5492 Vissenbjerg
Write the production number of your
insert here so that you have it at hand
in case you need to contact us.
Distance to flammable materials (mm)
300
500
Radiation area
Data for calculation of the chimney
Stove
Connecting
model
adaptor
ext.
SCAN
mm
DSA 5
179
Column 2 shows the flue gas temperature in the connecting adaptor.
Column 3 shows the lowest/minimum draft in Pa by rated value.
Production number
Floor
plate
1
2
Density of
Flue gas tem-
flue gas flow
perature
o
C
g/s
11,3
255
3
Minimum
draft
Pa
15

Advertisement

loading