Before the Cassette is Connected to the Chimney: Contact your local authorities to obtain the existing fire- and building regulations regarding the installation, or ask your local experts in that field, e.g., the chimney sweep, to install your cassette. All SCAN DSA cassettes are closed fireplaces.
- this is important in order to obtain an optimal airflow in the combustion material. Close the door after approx. 2 min. To avoid overheating, close the ash pan (SCAN DSA 3) as soon as the fire has caught on well.
Ceramic Packing Cord: All SCAN DSA cassettes are equipped with ceramic packing cord to ensure the tightness of the doors and the glasses. This packing cord is a wearing part and must be changed from time to time. Please consult your...
Page 5
MOUNTING OF THE CERAMIC SMOKE DEFLECTOR A ceramic smoke deflector is delivered with all SCAN DSA cassettes. Place the smoke deflector plate according to sketch 5; make sure that it is placed symmetrically in the cassette, i.e., with even amounts of free airspace on each side.
Page 6
Warranty conditions for SCAN wood-burning products All SCAN wood-burning stoves and inserts are made of first-class material and are subject to a strict quality control, before they leave the factory. However, an error may occur, wherefore we back all SCAN wood-burning stoves and inserts with an extensive five years limited warranty.