Summary of Contents for SCAN DSA 4

  • Page 1 INSTRUCTIONS FOR INSTALLATION AND USE SCAN DSA 4 Fireplace Insert SAVE THESE INSTRUCTIONS.
  • Page 2: Table Of Contents

    6.5 Door Glass: ..................................15 6.5.1 Replacing Broken Door Glass: ..........................15 6.6 Replacement part list: ..............................16 7. WARRANTY PROVISIONS FOR SCAN WOOD BURNING PRODUCTS ....Error! Bookmark not defined. 8. TROUBLESHOOTING ................................19 For future reference, please record the serial number of your fireplace insert here.
  • Page 3: T1. Important Safety Notice

    For future reference, please take a moment to record the serial number of your fireplace insert on page 2. In the SCAN DSA 4 firebox you will find a Miscellaneous Hardware kit containing the following items: 1, Self-adhesive Flue Collar Gasket...
  • Page 4: Cautions

    DO NOT OPERATE THE FIREPLACE WITHOUT THE FIREBOX BAFFLE CASSETTE PROPERLY INSTALLED. BUILD FIRES DIRECTLY UPON THE HEARTH INSIDE THE FIREPLACE. DO NOT USE GRATES, IRONS OR ANY OTHER METHOD TO ELEVATE THE FIRE. THE SCAN DSA 4 FIREPLACE INSERT IS ONLY FOR FIREPLACE INSTALLATION.
  • Page 5: Introduction / Instructions For Use

    3. INTRODUCTION / INSTRUCTIONS FOR USE 3.1 About the SCAN DSA 4 fireplace SCAN DSA 4: CAUTION: Do not operate the fireplace with the start device open or ajar, as this will produce extreme temperatures within the fireplace (over-firing), which could result in a house fire. Damage caused by...
  • Page 6: Ceramic Gasket

    Ceramic gasket: The SCAN DSA 4 fireplace is equipped with ceramic gasket to ensure the door and glass are tightly sealed. This ceramic gasket is a wearing part and must be renewed from time to time. Please consult your authorized dealer for replacement parts.
  • Page 7: Installation (Qualified Technicians Only)

    CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment. In the U.S. only, the Scan DSA 4 is approved for installation into a factory-built, zero-clearance fireplace and chimney listed to UL 127. WARNING: Check all local building and safety codes before the installation. The installation instructions and appropriate code requirements must be followed exactly and without compromise.
  • Page 8: Fireplace Placement Requirements

    NOTE: Allow extra room for installation, especially above the insert when using a direct or positive connection. 4.2 Fireplace placement requirements The fireplace must be placed so that no combustible materials are within, or can swing within (e.g. drapes ,doors), 36” (915 mm) of the front of the fireplace. The minimum clearances, facing, and hearth requirements in the illustration below must bet met.
  • Page 9: Mantel Clearances

    4.3.1 Mantel Clearances 4.3.2 Hearth and floor protection requirements: • When the bottom of the fireplace is installed less than 3 1/2” (88 mm) to the floor, the floor requires thermal protection of 3/4 inch (19 mm) thick mineral fiber millboard with a value of k=1.12 BTU/IN FT F.
  • Page 10: Masonry Fireplace Requirements

    (negative pressure from exhaust fans, chimneys, air infiltration, etc.), may adversely affect draft. Consult your local Scan dealer for advice and suggestions to help alleviate environmental issues specific to your installation that may be cause less than optimal performance.
  • Page 11: Surround Panel Installation (See Part Numbers Below)

    4.7 Factory-built, Zero –clearance Fireplace ( U.S. ONLY ) The Scan DSA 4 may be installed into a factory-built, prefabricated fireplace in the U.S. only. The factory-built • replace and its chimney must be listed per UL 127. Warning: Under no circumstances is this heater to be installed in a makeshift or "temporary" manner.
  • Page 12: Combustion Air Supply

    (fresh air duct). Draft Requirements: The SCAN DSA fireplace is only one component of the total system. The venting system is equally important for achieving the required flow of combustion air to the fire chamber and for safely exhausting unburned combustion by-products. If the venting system’s design does not promote these ends, the system may not function properly.
  • Page 13: Operation

    Your SCAN DSA wood-burning fireplace is designed for burning dry, natural, well-seasoned wood only. Ask your authorized SCAN dealer where to obtain seasoned fuel in your area. Wood should be stored in a dry, well-ventilated area for at least one year before being used for fuel. Some trees have very high moisture content and it is necessary to thoroughly dry the wood.
  • Page 14: Starting A Fire

    Satin Black and Gray touch-up paint is available from your local Scan dealer for repair of blemishes or scratches. As there may be minor color differences, it is recommended to repair large areas with natural borders. You will get the best result if the fireplace is painted while it is lukewarm (if the fireplace is too hot, the paint will be granular).
  • Page 15: Removing Baffle Cassette For Cleaning

    Be sure that the fire is out and the fireplace is cold before removing the baffle cassette. The placement of firebricks, skamol liners and smoke baffles of your SCAN DSA fireplace is illustrated below. Removal of all firebricks, skamol liners and the baffle cassette should follow in the reverse numeric order (e.g.
  • Page 16: Replacement Part List

    Make sure to maintain the same distance between the door edges and the insert on both sides and that the door and the latch work properly. Replacement part list: Caution: Use only original SCAN DSA 4 replacement parts. Do not use substitute materials. Description Part Number...
  • Page 17 Jøtul or Scan Stove or Fireplace. This paragraph sets forth the sole remedy available under this warranty in the event of any defect in the Jøtul or Scan Stove or Fireplace.
  • Page 18 Scan Stove or Fireplace. If you believe your Jøtul or Scan Stove or Fireplace is defective, you should contact your nearest authorized Jøtul or Scan dealer, who will process a warranty claim. IN ORDER TO QUALIFY FOR WARRANTY COVERAGE, JØTUL MUST RECEIVE NOTICE OF A POSSIBLE DEFECT WITHIN SIXTY (60) DAYS OF THE DATE THE DEFECT IS FIRST DISCOVERED, OR REASONABLY COULD HAVE BEEN DISCOVERED.
  • Page 19: Troubleshooting

    8. TROUBLESHOOTING Smoke: • Insufficient chimney draught! • Check chimney height. Recommended height is minimum 15 feet. • Check if the chimney has the right dimension. • Check if the smoke pipe or chimney is blocked. • Check if the chimney has the right height compared to the surroundings. •...
  • Page 20 Manufactured by Jøtul North America, Inc. 55 Hutcherson Dr. Gorham, Maine Krog-Iversen& Co. A/S, DK-5492 Vissenburg Denmark 139133_Rev_C August 2010...