Control Panel Layout

1
2
1. Main Printed Circuit Board (PCB)
The main PCB that provides the terminals connection to remote
keypads and detection devices, see PCB Layout on next page for
full details.
2. Mains Transformer
The mains transformer is housed under this protected area and
provides AC power to the main PCB.
3. Mains Connection
The AC Mains supply is connected to a 3 way Euro Type fused
terminal block, which is fitted with a 500mA fuse.
To Power Supply
Module
Fuse T500mA
P0031-LI-01.00
3
4
N
E
L
5
4. Mains Supply Cable Entry
The mains supply cable must be routed into the control panel
housing via this cable entry.
5. Standby Battery
The system housing will accept a 12V 7Ah battery to provide
continued operation in the event of an AC mains failure. Connect
the red battery lead to the positive terminal of the battery and
then connect the black battery lead to the negative terminal.
The system will only become "live" when the AC supply is
connected or the "Battery On" pins are shorted.
Control Panel
12V 7Ah
Sealed Lead Acid Battery
7