Arm Options 2

The set of options controls how the system responds for each
arming mode.
Locations:
- Away Arm: Options 2.
2042
- Stay Arm 1: Options 2.
2142
- Stay Arm 2: Options 2.
2242
- Stay Arm 3: Options 2.
2342
Entry Mode:
Bit Toggle Selection (see page 16).
1
Only Exit when Ready
On: The exit mode can only be started if all zones are healthy
(System Ready).
Off: The exit mode can be started even if one or more zones are
active. The active zones will be indicated on the remote
keypads and a fault tone is generated.
2
Instant Bell on ATS Fault
On: The bell delay is overridden and set to zero, when the Alarm
Transmission System (ATS/on-board communicator) fault
occurs.
Off: The bell delay remains unchanged, when an ATS fault
occurs.
3
Alarms are Engineer Reset
On: Intruder alarms require an engineer to reset the system back
to normal.
Off: Intruder alarms can be reset by users.
4
Enable Bell Squawk
On: The bell output is pulsed once for a very short period when
the system is armed and twice when disarmed.
Off: The bell output operates as normal.

Arm Keyswitch Control

The set of options controls how the system responds when a
keyswitch zone is used for arming.
Locations:
- Away Arm: Keyswitch Options.
2043
- Stay Arm 1: Keyswitch Options.
2143
- Stay Arm 2: Keyswitch Options.
2243
- Stay Arm 3: Keyswitch Options.
2343
Entry Mode:
Bit Toggle Selection (see page 16).
1
Silent Arm
On: The exit tone remains silent during exit mode, when a
keyswitch is used to arm the system.
Off: The exit tone is generated during exit mode, when a
keyswitch is used to arm the system.
2
Disabled when Armed
On: The keyswitch is disabled when armed (arm only keyswitch).
Off: The keyswitch remains enabled when the system is armed.
3
Instant Arm
On: The system is armed instantly when a keyswitch is used.
Off: The normal exit mode is used to arm the system.

Auto Arm/Disarm

This set of options controls how the system Control Timers can be
used to automatically arm/disarm the system at specific times
and on specific days of the week. Please refer to page 24 for
details on Control Timer configuration.
Locations:
- Away Arm: Auto Arm/Disarm
2051
- Stay Arm 1: Auto Arm/Disarm.
2151
- Stay Arm 2: Auto Arm/Disarm.
2151
- Stay Arm 3: Auto Arm/Disarm.
2151
Entry Mode:
Bit Toggle Selection (see page 16).
22
1
Arm with Control Timer 1
On: The selected mode is automatically armed by Control Timer
1.
Off: The selected mode is not armed automatically.
2
Arm with Control Timer 2
On: The selected mode is automatically armed by Control Timer
2.
Off: The selected mode is not armed automatically.
3
Arm with Control Timer 3
On: The selected mode is automatically armed by Control Timer
3.
Off: The selected mode is not armed automatically.
4
Arm with Control Timer 4
On: The selected mode is automatically armed by Control Timer
4.
Off: The selected mode is not armed automatically.
5
Disarm with Control Timer 1
On: The selected mode is automatically disarmed by Control
Timer 1.
Off: The selected mode is not disarmed automatically.
6
Disarm with Control Timer 2
On: The selected mode is automatically disarmed by Control
Timer 2.
Off: The selected mode is not disarmed automatically.
7
Disarm with Control Timer 3
On: The selected mode is automatically disarmed by Control
Timer 3.
Off: The selected mode is not disarmed automatically.
8
Disarm with Control Timer 4
On: The selected mode is automatically disarmed by Control
Timer 4.
Off: The selected mode is not disarmed automatically.