01 Panel Speaker Volume
This option controls the level (0-10) of the exit, entry, fault and
warning tones from the control panel speaker. Default = 5.
02 Chime Volume
This option controls the level (0-10) of the chime tone from the
control panel speaker. Default = 5.
03 Advisory Tone Volume
This option controls the level (0-10) of the advisory tones from the
control panel speaker. Default = 5.
04 Alarm Tone Volume
This option controls the level (0-10) of the alarm tones from the
control panel speaker. Default = 10.

Hardware - Output Monitoring

This option enables/disables fault monitoring of the control panel
outputs.
Locations:
3310
Entry Mode:
Bit Toggle Selection (see page 16).
1
Panel Output 1 (Bell)
On: The output is monitored for faults.
Off: The output is not monitored.
2
Panel Output 2 (Strobe)
On: The output is monitored for faults.
Off: The output is not monitored.
3
Panel Output 3
On: The output is monitored for faults.
Off: The output is not monitored.
4
Panel Output 4
On: The output is monitored for faults.
Off: The output is not monitored.

Hardware - Monitoring

This set of options allows the monitoring of the control panel
hardware to be enabled or disabled.
Locations:
3311
Entry Mode:
Bit Toggle Selection (see page 16).
1
Panel Box Tamper
On: The box tamper is monitored for activity.
Off: The box tamper is not monitored.
2
Auxiliary Fuse
On: The auxiliary 12V fuse is monitored for faults.
Off: The auxiliary 12V fuse is not monitored.
3
System Voltage
On: The system voltage is monitored for faults.
Off: The system voltage is not monitored.
4
Battery Presence
On: The standby battery is monitored for its presence.
Off: The standby battery is not monitored.
5
Mains AC
On: The mains supply is monitored for its presence.
Off: The mains supply is not monitored.
6
Telephone Line
On: The telephone line connection is monitored for faults.
Off: The telephone line connection is not monitored.
7
Bell Tamper
On: The bell tamper input is monitored for activity.
Off: The bell tamper input is not monitored.
24

Configuration

This set of options allows the system operation and features to be
altered.
Locations:
3401
Entry Mode:
Bit Toggle Selection (see page 16).
1
Auto BST/GMT
On: The system clock is automatically put forward by one hour
on the last Sunday in March at 2.00AM and put back by one
hour on last Sunday in October at 2:00AM.
Off: The system clock remains unchanged.
2
Battery Test by Control Timer 5 and Disarm
On: The battery test feature is invoked when Control Timer 5
switches on and every time the system is disarmed.
Off: The battery test feature is performed by the "Battery Test
Period" timer.
3
Reinstate Bypassed Zones on Disarm
On: Any zones that have been manually bypassed are
automatically reinstated when the system is disarmed.
Off: Bypassed zones remain bypassed after the system is
disarmed.
4
Enable EN50131-1 Requirements
On: The system operates so as to comply with requirements of
EN50131-1.
Off: The system operates as normal.
5
Disable Bell when Disarmed
On: The bell output is disabled when the system is disarmed.
Off: The bell output is enabled when the system is disarmed and
if a 24hr alarm zone is activated it will trigger the bell output.
6
Disable Communications when Disarmed
On: The control panel onboard communicator is disabled when
the system is disarmed.
Off: The onboard communicator is enabled when the system is
disarmed.
7
Tamper Alarms are Engineer Reset
On: Tamper alarms require an engineer to reset the system.
Off: The user can reset tamper alarms.
8
View Active Zones
On: Zone activity is displayed when the system is disarmed.
Off: Zone activity is not displayed.

Control Timers

The SEC8 has five programmable Control Timers, each timer has
a switch on time (On Time), switch off time (Off Time) and days of
operation for both the On and Off times. Control Timer can be
used to automatically arm the system or lock users from
accessing the system. The control timer can also be assigned a
"Link" number, which in turn is used to control "Link Control"
output types, for details on link control, see page 29.
Locations:
to
3501
Control Timers 1 to 5: On Time.
to
3511
Control Timers 1 to 5: Off Time.
Entry Mode:
Number Entry (see page 17).
Enter time in 24hour format, e.g., 1715 = 05.15 PM.
Locations:
to
3521
Control Timers 1 to 5: On Time Days.
to
3531
Control Timers 1 to 5: Off Time Days.
Entry Mode:
Bit Toggle Selection (see page 16).
Options 1 to 7 = Sunday to Saturday.
3505
3515
3525
3535
P0031-LI-01.00