4. Keypad Configuration

This section covers programming of the remote keypads.

Keypad Options 1

This first set of options controls how the selected keypad onboard
keys and tamper function.
Locations:
to
4111
Keypads 1 to 4: Options 2.
Entry Mode:
Bit Toggle Selection (see page 16).
1
Fire Activation from keys 1 and 3
On: Pressing keys 1 and 3 on the selected keypad at the same
time will generate a fire alarm event.
Off: The selected keypad cannot generate fire alarm events.
2
Medical Activation from keys 4 and 6
On: Pressing keys 4 and 6 on the selected keypad at the same
time will generate a medical alarm event.
Off: The selected keypad cannot generate medical alarm events.
3
PA Activation from keys 7 and 9
On: Pressing keys 7 and 9 on the selected keypad at the same
time will generate a panic alarm (PA) event.
Off: The selected keypad cannot generate panic alarm events.
4
Silent Keypad PA
On: If option 3 is enabled the selected keypad will generate a
silent panic alarm event.
Off: If option 3 is enabled the selected keypad will generate an
audible panic alarm event.
5
Quick Away Arm Enabled
On: The away arm mode can be carried out from the selected
keypad by simply pressing key.
Off: The user passcode must be entered at the selected keypad
before the away arm mode can be selected.
6
Quick Stay Arm Enabled
On: The stay arm mode can be carried out from the selected
keypad by simply pressing key.
Off: The user passcode must be entered at the selected keypad
before the stay arm mode can be selected.
7
Quick Bypass Enabled
On: The zone bypass feature can be invoked at the selected
keypad by simply pressing key.
Off: The user passcode must be entered at the selected keypad
before the bypass feature can be selected.
8
Keypad Tamper Enabled
On: The lid tamper on the selected keypad is monitored.
Off: The lid tamper on the selected keypad is not monitored.

Keypad Options 2

This second set of options controls how the selected keypad
functions when invalid keys are pressed (code tamper).
Locations:
to
4121
Keypads 1 to 4: Options 2.
Entry Mode:
Bit Toggle Selection (see page 16).
1
Enable Code Tamper
On: Entering 15 or more invalid key presses on the selected
keypad will generate a code tamper event.
Off: The selected keypad cannot generate code tamper events.
2
Lockout Keypad
On: If the "Enable Code Tamper" option is enabled for the
selected keypad, the keypad operation will be locked out for
5 minutes if a code tamper event is generated.
26
4114
4124
Off: The selected keypad operation remains unchanged.

Keypad Sounds

This set of options controls how the selected keypad generates
sounds from its onboard sounder.
Locations:
to
4131
Keypads 1 to 4: Sounds.
Entry Mode:
Bit Toggle Selection (see page 16).
1
Alarm Tones
On: The selected keypad generates alarm tones.
Off: The selected keypad will not generate alarm tones.
2
Trouble Tones
On: The selected keypad generates trouble tones.
Off: The selected keypad will not generate trouble tones.
3
Chime Tones
On: The selected keypad generates chime tones.
Off: The selected keypad will not generate chime tones.
4
Entry Tones
On: The selected keypad generates entry tones.
Off: The selected keypad will not generate entry tones.
5
Exit Tones
On: The selected keypad generates exit tones.
Off: The selected keypad will not generate exit tones.
6
Key Press Tones
On: The selected keypad generates key press tones.
Off: The selected keypad generates a short click tone when keys
are pressed.
7
Advisory Tones
On: The selected keypad generates advisory tones.
Off: The selected keypad will not generate advisory tones.
8
Tamper Tones
On: The selected keypad generates tamper alarm tones.
Off: The selected keypad will not generate tamper alarm tones.

5. Reserved

4134