6. Panel Outputs and Devices

This section covers programming of the control panel outputs,
communication ports and other devices that maybe connected to
the control panel.

Panel Output Type

This set of options allows the output type (function) to be
assigned to the control panel high current outputs.
Locations:
to
6111
Panel Outputs 1 to 4: Output Type.
Entry Mode:
Selection List (see page 15).
Enter the two digit group number followed by the two digit type
number, e.g., 3001 = "Zone 01 Alarm".

Panel Output Attributes

This set of options allows the output attributes to be assigned to
the control panel high current outputs.
Locations:
to
6121
Panel Outputs 1 to 4: Output Attributes.
Entry Mode:
Bit Toggle Selection (see page 16).
1
Latching
On: The selected output latches on when triggered and is only
cleared when the user resets the system.
Off: The selected output responds normally.
2
Inverted
On: The selected output is inverted, off when active and on when
inactive.
Off: The selected output responds normally.
3
User Test
On: The selected output is activated when the user output test is
selected.
Off: The selected output remains unchanged during the user
output test.
4
Pulse 1
On: The selected output activates for the duration of the "Pulse
1 Time" system timer, see page 23.
Off: The selected output responds normally.
5
Pulse 2
On: The selected output activates for the duration of the "Pulse
2 Time" system timer, see page 23.
Off: The selected output responds normally.
6
Delay 1
On: The selected output activates after the delay set by the
"Delay 1 Time" system timer, see page 23.
Off: The selected output responds normally.
7
Delay 2
On: The selected output activates after the delay set by the
"Delay 2 Time" system timer, see page 23.
Off: The selected output responds normally.
8
Armed Only
On: The selected output only activates if the system is armed.
Off: The selected output responds normally.
If "Pulse 1" and "Pulse 2" options are enabled then the
selected output activates for the duration of the "Pulse
3 Time" system timer, see page 23.
If "Delay 1" and "Delay 2" options are enabled then the
selected output activates after the delay set by the
"Delay 3 Time" system timer, see page 23.
P0031-LI-01.00
6114
6124

Output Types

The output types are grouped together in the following groups:
Group
Description
00
Global
Global system output function.
01
Area
Not available.
02
Control Timer
Control Timers 1 to 5.
03
Remote Control
Remote control outputs 1 to 5.
04
Link Control
Input linked logical conditioned outputs.
20
Zone Mimic
Zones 1 to 10 mimic outputs.
30
Zone Alarm
Zones 1 to 10 alarm outputs.
40
Zone Tamper
Zones 1 to 10 tamper alarm outputs.
50
Zone Masked
Zones 1 to 10 masked outputs.
60
Zone Fault
Zones 1 to 10 fault outputs.
70
Zone Bypassed
Zones 1 to 10 bypassed outputs.
80
User Access
Users 00 to 10 access outputs.

00: Global

The table below list the output function available in this group:
No
Type & Description
00
Not Used
This output type does not activate.
01
AC Fault
This output type activates when the mains supply has been
removed for the duration of the AC Fail timer.
02
ATS Fault
This output type activates when the onboard communicator
detects a phone line fault (Alarm Transmission Fault).
03
Unset
This output type activates when the system is in the disarmed
state.
04
Armed
This output type activates when the system is armed in any of
the armed modes (Away or Stay)
05
Part Armed
This output type activates when the system is armed in any of
the Stay armed modes.
06
Armed/Alarm
This output type activates when the system is armed and pulses
when an alarm is generated.
07
Bell Active
This output type activates when an alarm is generated (it may be
delayed if the bell delay time is greater than zero). The duration
of this output type is controlled by the "Bell Duration" timer.
08
Strobe Active
This output type activates when an alarm is generated and
deactivates when the system is reset
.09
Alarm
This output type activates when an intruder alarm is generated.
10
Confirmed Alarm
This output type activates when two different zones cause an
intruder alarm.
27