Banner Text; Remote Control Labels; System Links - Securacom SEC8 Installation Manual

8 zone intruder alarm system
Hide thumbs Also See for SEC8:
Table of Contents

Advertisement

Locations:
to
3541
Control Timers 1 to 5: Link.
Entry Mode:
Number Entry (see page 17).

Banner Text

This set of options allows you to customise the text that is
displayed on LCD keypads. The "Stay Arm Banners" are shown
when the system has been armed in the relevant stay mode. The
"Keypad Banner" is displayed on the top line when the system is
disarmed. The "Engineer Reset Banner" is displayed on the
bottom line when the system requires an engineer to reset the
system. The top line will always show "Call Engineer".
Locations:
- Stay Arm 1 Banner.
3601
- Stay Arm 2 Banner.
3602
- Stay Arm 3 Banner.
3603
- Keypad Banner.
3604
- Engineer Reset Banner.
3605
Entry Mode:
String Edit - Text Mode (see page 18).

Remote Control Labels

This set of options allows you to customise the text label that is
displayed on LCD keypads for each remote control output. When
the user accesses the remote control output menu, the labels are
displayed, e.g. "Garden Lights".
Locations:
to
3621
Remote Control 1 to 5: Labels.
Entry Mode:
String Edit - Text Mode (see page 18).

System Links

Each system output can be assigned a "Link" number, which in
turn is used to control the "Link Control" output types, for details
on link control, see page 29.
Locations:
to
3901
System Outputs 01 to 50: Link.
Entry Mode:
Number Entry (see page 17).
The table below shows the system output types and their
corresponding number 01 to 50. For details of each system
output function, please see page 27.
System Link Types
01 = AC Fault
02 = ATS Fault
03 = System Open
04 = System Armed
05 = System Part Armed
06 = System Armed/Alarm
07 = Bell
08 = Strobe
09 = Intruder Alarm
10 = Confirmed Alarm
11 = Alarm Abort
12 = Fire Alarm
13 = PA Alarm
14 = Duress Alarm
15 = 24hr Alarm
16 = Medical Alarm
17 = Tamper Alarm
18 = Ready for Arming
19 = Trouble
20 = Alert
P0031-LI-01.00
3545
3625
3950
26 = PSTN Off-Hook
27 = PSTN Ringing
28 = Battery Fault
29 = Control Panel Box Tamper
30 = Bell Tamper
31 = Engineer on Site
32 = Detector Reset
33 = Switched 12V
34 = System Low Volts
35 = Exit Mode
36 = Entry Mode
37 = Second Entry Mode
38 = General Alarm
39 = Auxiliary
40 = Warning
41 = Security Key Active
42 = Output Fault
43 = Engineer Reset Required
44 = Device Fault
45 = Panel AC Present
System Link Types
21 = Bypass
22 = In Walk Test
23 = Flash 1 Second
24 = User Test Active
25 = PSTN Fault
46 = Cleaner Bypass
47 = 2-Wire Smoke
48 = 2-Wire Smoke Alarm
49 = 2-Wire Smoke Fault
50 = Door Access
25