Led Indications - Securacom SEC8 Installation Manual

8 zone intruder alarm system
Hide thumbs Also See for SEC8:
Table of Contents

Advertisement

LCD

LED Indications

The figure bellow shows the LED indicators for both the LED and LCD remote keypads:
Fault & Status Messages
Faults and status messages may be indicated during the disarmed mode or after the user disarms the system. The table below shows the
message for both the LED and LCD remote keypads:
LCD
Resetting Faults & alarms
If a fault or alarm has occurred it can be reset as follows:
1.
Enter a valid access code, this will silence the alarm or
cancel the alert.
2.
Enter a valid access and press
3.
Enter
to exit the menu. If the fault is still present it
*99
will still be indicated.
40
LED
Description
RP ? A
A panic alarm was generated at keypad ? by pressing keys 7 and 9.
A fire alarm was generated at keypad ? by pressing keys 1 and 3.
RF ? A
A medical alarm was generated at keypad ? by pressing keys 4 and 6.
RD ? A
OPF ?
The control panel has detected a fault on panel output ?.
OPR ?
The fault on panel output ? has restored.
Icon
LED
Description
AC
Mains AC power is off.
BF
The standby battery in the control panel has a fault.
LF
The onboard communicator has detected a fault with the telephone line.
The box tamper on the control panel has activated.
PT
BT
The bell tamper on the control panel has activated.
CE
Call engineer to reset the system.
The service timer has expired and the installation company should be contacted.
CR
One or more 2-wire smoke detectors have activated a fire alarm.
SA
One or more 2-wire smoke detectors have a fault.
SF
Keypad ? is no longer reporting to the control panel.
R?
The box tamper on keypad ? has activated.
T?
Output ? on the control panel has a fault.
O?
Alarm activated on zone ??.
??
to reset the system.
R
Name
LED
Description
Power
Green
Mains AC power is present.
Ready
Green
The system is ready for arming.
Armed
Green
The system is armed (Away or Stay).
Fault
Yellow
The system has one or more faults.
Bypass
Yellow
One or more zones are bypassed.
Alert
Red
One or more faults/alarms require attention.
Alarm
Red
One or more alarms have occurred.
P0031-LI-01.00