Remote Keypads

PCB Layouts

2
3
4
LED Remote Keypad
2
LCD Remote Keypad
1. Network Connections
The remote keypad is connected to the network terminals located
at the bottom left hand side of the PCB.
2. Address Selection
Each remote keypad must be assigned a different address using
the Address selector. Move the jumper to the required position 1,
2, 3 or 4.
3. Tamper Switch
The lid tamper for each remote keypad can be enabled or
disabled if required. Please refer to page 26 for further details.
4. Piezo Sounder
The piezo sounder generates low level alarm, key press, and
warning tones. Each type of tone can be enabled or disabled for
each remote keypad, please refer to page 26 for further details.
10
1
3

Wiring Detection Devices

The SEC8 provides 8 zones for connecting detection devices such
as movement sensors and magnetic door contacts. Each zone is
fully programmable to allow for maximum flexibility (see page 18
for Zone Programming details). The program options for a zone
will also determine how the zone may be wired. The following
wiring options are available:

Normally Closed

This wiring configuration should be used when connecting
detection devices that only have a normally closed alarm output.
Connect the detector as shown below and ensure that the zone is
programmed for "Normally Closed" operation, see page 19.
1

Normally Open

This wiring configuration should be used when connecting
detection devices that only have a normally open alarm output.
Connect the detector as shown below and ensure that the zone is
4
programmed for "Normally Open" operation, see page 19.
Zy
Zx Com
Alarm
Alarm
1 Detector
Alarm
2 Detectors
Zx Com
Zy
Alarm
Alarm
1 Detector
Alarm
2 Detectors
P0031-LI-01.00