Group 50: Zone Masked; Group 60: Zone Fault; Group 70: Zone Bypassed; Group 80: User Access - Securacom SEC8 Installation Manual

8 zone intruder alarm system
Hide thumbs Also See for SEC8:
Table of Contents

Advertisement

No
Type & Description
02-
Zone 02 - 10 Tamper
10
As Zone 01 Tamper.

Group 50: Zone Masked

The mask condition of each zone can be assigned to an output:
No
Type & Description
01
Zone 01 Masked
This output type activates when zone 01 generates a mask fault
and deactivates when the fault is cleared and reset.
02-
Zone 02 - 10 Masked
10
As Zone 01 Masked.

Group 60: Zone Fault

The fault condition of each zone can be assigned to an output:
No
Type & Description
01
Zone 01 Fault
This output type activates when zone 01 generates a fault and
deactivates when the fault is cleared and reset.
02-
Zone 02 - 10 Fault
10
As Zone 01 Fault.

Group 70: Zone Bypassed

The bypass condition of each zone can be assigned to an output:
No
Type & Description
01
Zone 01 Bypassed
This output type activates when zone 01 is bypassed and
deactivates when the zone is reinstated.
02-
Zone 02 - 10 Bypassed
10
As Zone 01 Bypassed.

Group 80: User Access

The system access of each user can be assigned to an output:
No
Type & Description
00
User 00 Access
This output type activates for 30 seconds after user 00 has
entered their access code.
01-
User 01 - 10 Access
10
As User 00 Access.

Communication Port

This option allows the operating mode for the onboard
communication port to be configured.
Locations:
- Com Port 1: Mode.
6201
Entry Mode:
Selection List (see page 15).
0
UDL
This mode configures the selected communication port for UDL
direct link operation. The USB-Link should be connected to the
computer and the other end should be connected to the selected
control panel communication port.
1
Printer
This mode configures the selected communication port for printer
operation. Use this mode when using a terminal program via the
USB-Link to capture the printer output from the control panel.
2
GSM Module
This mode configures the selected communication port for GSM
Module operation. Use this mode when connecting a GSM Module
to the control panel.
30
3

IP Module

This mode configures the selected communication port for IP
Module operation. Use this mode when connecting an IP Module
to the control panel.
4
Contact ID
This mode configures the selected communication port for
Contact ID operation. In this mode the Contact ID in ASCII format
is sent to the port.
5
Debug Data
This mode configures the selected communication port for Debug
Data operation. Use this mode when using a terminal program via
the USB-Link to capture the debug data from the control panel.
GSM & SMS Centre
These options allow the GSM and SMS Centre to be configured.
Locations:
- GPRS APN Name
6301
- SIM Password
6302
- SMS Centre Number
6311
Entry Mode:
String Edit - Number Mode (see page 17).
SMS Centre Number
The panel can send SMS to mobile phones, it uses the ETSI ES
201 912 protocol 1. The SMS Centre numbers are listed below:
Country
Operator
UK
BT
Ireland
Eirecom
Germany
T-Com
Belgium
Belgacom
France
France Telecom
Switzerland
Swisscom
Netherlands
KPN Telecom
South Africa
Telkom
Caller Line Identity must be enabled in order for the SMS Centre
to accept the message.
IP Module
These options allow the IP Module to be configured.
Locations:
- IP Address
6401
- Subnet Mask
6402
- Gateway Address
6403
- Port Number
6404
Entry Mode:
String Edit - Number Mode (see page 17).
SMS Centre Number
17094009
17409900
0193010
14974800
0809101000
0622100000
0673644444
1091969
P0031-LI-01.00

Advertisement

Table of Contents
loading