Remove Right Fuel Tank Bracket (if so
equipped), Switch Bracket, Electric Starter,
and Housing/Cover Panel Assembly
1. Disconnect the wiring harness bullet connectors
for the oil sentry and ignition module. Remove
the mounting screw securing the ground lead.
See Figures 9-24 and 9-25. Disconnect the
rectifier-regulator lead connections if used.
Figure 9-24. CS8.5 (spec. 92xxxx), CS10, and CS12
Ground Lead Location.
Figure 9-25. CS8.5 (spec. 95xxxx) Ground Lead
Location.
2. Remove the two front fuel tank bracket (not used
on CS8.5 [spec. 95xxxx]) mounting screws,
attaching the throttle lever mechanism, switch
and oil sentry light bracket. On electric start
engines the electrical control panel housing will
also be included. Note the washer used on PTO
side screw only. See Figure 9-31.
Figure 9-26. CS4, CS6 Right Tank Bracket
Mounting Details.
Figure 9-27. CS8.5 (spec. 92xxxx), CS10, and CS12
Right Tank Mounting Bracket Details.
Electric Start Engines Only
3. Remove the two screws securing the control
panel and mounting bracket for the electrical
components. See Figure 9-28.
Figure 9-28. Removing Control Panel Screws.
Section 9