Figure 8-68. Installing End Cap.
12. Install and tighten the two thru bolts.
13. Make sure the dust cover is in place on solenoid.
Install solenoid engaging the plunger end with
the yoke of the drive lever. Check by pulling
solenoid towards the rear. Mount the solenoid to
the starter using the two hex flange nuts. Tighten
securely. See Figure 8-69.
Figure 8-69. Installing Thru Bolts.
Electrical System and Components
14. Connect the braided (brush) lead to lower main
solenoid terminal and secure with the loose hex
flange nut. See Figure 8-70.
Figure 8-70. Connecting Brush Lead.