Disassembly
Figure 9-77. Separating Closure Plate From
Crankcase.
Steps 3-7 should be performed only if further
disassembly or servicing in the respective areas is
necessary.
3. Remove the two hex flange screws mounting the
oil sentry gauge and the single screw holding the
wire shield in place. See Figure 9-78.
Figure 9-78. Removing Shield and Oil Sentry™.
4. Pull the grommet out of the cutout in the casting
and remove the oil sentry gauge. Note the routing
of the wire.
5. Remove the governor gear/flyweight assembly by
carefully applying upward pressure with two
small screwdrivers between the gear and the
closure plate bosses. This will unseat the
retaining ring from the groove, allowing removal
of the gear and mounting components by pulling
upward. Do not pry against the gasket surface.
Note the placement and order of all parts. See
Figure 9-79.
9.18
Figure 9-79. Removing Governor Gear.
6. Remove the crankshaft seal. See Figure 9-80.
Grommet
Figure 9-80. Removed Crankshaft Seal.
7. Press out the crankshaft bearing using an arbor
press. Use an internal bearing puller to remove
the balance shaft bearing.
Figure 9-81. Bearing Removal Using a Press.