Kohler Command PRO CS Service Manual page 154

4-12.75 hp horizontal crankshaft
Table of Contents

Advertisement

Section 11
Reassembly
Install Blower Housing and Electric
Starter Cover Panel (If So Equipped)
1. Install the blower housing behind the throttle link
and dampening spring. Start all the hex flange
screws. On CS4 and CS6 engines, secure the
ground lead with the silver screw in the upper
right hand location. See Figures 11-96, 11-97, and
11-98. Torque the screws to 7 N·m (62 in. lb.).
Figure 11-96. Installing Blower Housing.
Figure 11-97. CS4, CS6. Silver Screw and Ground
Lead Location.
11.26
Figure 11-98. CS8.5 (spec. 92xxxx), CS10, CS12.
Blower Housing Installed.
2. Attach the electric starter cover panel (if so
equipped) to the right tank support with the three
phillips head screws and one flange nut. See
Figure 11-99.
Figure 11-99. CS8.5 (spec. 92xxxx), CS10, CS12.
Attaching Electrical Starter Cover Panel.

Advertisement