Troubleshooting; Level 1~Level 2 Repair - Motorola D10 Service Manual

Product family d10 dual band wireless telephone
Hide thumbs Also See for D10:
Table of Contents

Advertisement

BenQ
Level 1 ~level 2 repair
Symptom
Probable Cause
1.Unit
a).Battery either
doesn't turn
discharged or
on
defective.
b).Shield case short
with components
2.Keypad no
Keypad bottom short 1.Disassembly to replace the keypad metal
function.
3.Buzzer no
Components shift
function
4.Vibrator no
Components shift
function
5.Speaker
Components shift
no function
6.Micphone
Components shift
no function
7.Datacable
Components are at
no function
fault.
8.Can't
Battery or charger is
charge
at fault

Troubleshooting

1. Measure battery voltage. If the battery
voltage is <3.2V, recharge the battery
using the appropriate battery charger.
2.If the battery can't be recharge, replace
the battery.
1.Visually inspect the RF/BB shielding
case. If they become deformed , replace
the shielding case.
dome.
1.Disassembly to visually inspect the U13.
If the spring of the U13 becomes
deformed, replace the U13.
1.Disassembly to visually inspect the M1. If
the spring of the M1 becomes deformed
and doesn't contact well with PCB pads,
replace the M1.
1.Disassembly to visually inspect the LS1.
If the spring of the M1 becomes
deformed and doesn't contact well with
PCB pads, replace the LS1.
1.Disassembly to visually inspect the X2. If
the cover of the X2 is not matched with
the micphone hole or micphone doesn't
contact well with PCB pads, replace the
cover of the X2 or micphone.
1.Measure voltage level if VR3 and
VR2B_SW voltage level are equal 2.9V.
1. Use the correct battery and charger to
check the charge function.
2.If charging function is ok, the battery or
charger is illegal.