Gateway ALR 9250R User Manual page 145

Table of Contents

Advertisement

System management submenu
All EMP-related settings occur from the System Management Submenu of
the server Main Menu. Change only the items below; all other default
settings should remain the same.
EMP Password: Any time you attempt to initiate a connection, a prompt
for the user password appears. If you never set up the EMP password,
anyone can access the EMP by clicking
through the password prompt.
OK
In the EMP password area of the System Management Submenu, type in a
password of up to eight alphanumeric characters. If the system beeps, the
password was not accepted; you must enter a different password.
EMP Access Modes: Choose either disabled, pre-boot, or always active,
depending on the type of EMP access needed. The tables "EMP Console
Access Modes (Server Configured for Console Redirect)" on page 129 and
"EMP Console Access Modes (Server not Configured for Console
Redirect)" on page 129 list what is available with a given setting.
EMP Restricted Mode Access: Set restricted mode to either enabled or
disabled. In enabled mode, the EMP console server control options, Power
On/Off and Reset, are NOT available. In disabled mode, these options are
available.
EMP Direct Connect/Modem Mode: Select
if a null modem
Direct Connect
serial cable directly connects the server COM2 port to the EMP console
client machine. If they are connected via a modem, select
.
Modem Mode
Console redirection submenu
To use the EMP, you must set the following options exactly as noted.
COM Port Address: Select 2F8. This is the COM2 port that the EMP must
use. The IRQ# setting is automatically assigned with the correct number
based on the COM port address choice.
Baud Rate: Select 19.2k.
Console Type: Choose PC ANSI.
Flow Control: Choose CTS/RTS + CD.