Dissassembly Procedures

Disassembly procedures for indoor unit

Operation procedures/pictures

Remove the front panel

Push the bulge of panel left and right sides with fingers,
Raise up the panel, along the groove of front case to
take out of the panel forcibly.(As shown in Fig.8-1)

Disassemble filter and wire-pressed clamp

Butt the middle part of filter, take off two clasps of both sides,
pull them frontward, and disassemble the filter.
To screw off 1pc bolt from wire-pressed clamp with screwdriver
then could disassemble the wire-pressed clamp.(As shown in Fig.
8-2)

Disassemble guide louver

Take off the middle part of guide louver from
the holders, then bend the guide louver slightly,
could disassemble it.(As shown in Fig.8-3)
Front panel
Filter
Guide louver
Fig.
Wire-pressed clamp
Fig.
Fig.