Operation procedures/pictures
Disassemble the capillary
Unsolder the double end of the capillary, can disassemble
the capillary, do not let the dregs block the capillary.
(As shown in Fig.8-32)
Disassemble the valve
Using the screwdriver to screw off 2pcs screw which
fix the valve, then unsolder the copper pipe which
connect with the valve. Then could disassemble the
valve. (As shown in Fig.8-33)
Disassemble the compressor
Unsolder the copper pipe which connect with
the compressor, and screw off 3pcs base screw,
can disassemble the compressor.(As shown in
Fig.8-34)