10.2 Install of the cassette type indoor unit

10.2.1 Schematic diagram of installation space
≥ 1 5 0 0
U n i t : m m
10.2.2 Select install location of the indoor unit
1. Obstruct should put away from the intake or outlet vent of the indoor unit so that the airflow can be
blown though all the room.
2. Make sure that the installation had accord with the requirement of the schematic diagram of
installation spaces.
3. Select the place where can stand 4 times of the weight of the indoor unit and would not increase the
operating noise and oscillate.
4. The horizontally of the installation place should be guaranteed.
5. Select the place where is easy to drain out the condensate water, and connect with outdoor unit.
6. Make sure that there are enough space for care and maintenance. Make sure that the height between
the indoor unit and ground is above 1800mm.
7. When installing the suspender bolt, check if the install place can stand the weight 4 times of the unit's.
If not, reinforce before installation. (Refer to the install cardboard and find where should be
reinforced)
Note!
There will be lots of lampblack and dust stick on the acentric fan, heat exchanger and water pump
Models
GKH12K3CI
GKH18K3CI
GKH24K3CI
GKH30K3CI
GKH36K3CI
GKH42K3CI
H(mm)
38
≥ 1 5 0 0
250
260
340