Advertisement

Fengyun Series
1
Introduction and Features
Model
Remarks
~

Advertisement

Table of Contents
loading

Summary of Contents for Gree Fengyun Series

  • Page 1 Fengyun Series Introduction and Features Model Remarks...
  • Page 2 Remarks Model 230V 220V 240~...
  • Page 3: Specifications And Technical Parameters

    Fengyun Series Specifications and Technical Parameters Model GWCN24C1ND1BA GWCN24C1NK1BA GWCN28C1TK1AA COOLING COOLING COOLING Function 208 - 230V Rated Voltage 220-240V~ 220-240V~ Rated Frequency 60Hz 50HZ 50Hz Total Capacity (W/Btu/h) 6450/22000 6850 8000W/28000Btu/h Power Input (W) 2000 2200 3200 Rated Input (W)
  • Page 4 Model of Outdoor Unit GWCN24C1ND1BA/O GWCN24C1NK1BA/O GWCN28C1TK1AA/O Compressor TECUMSEH Shanghai Hitachi HIGHLY Manufacturer/trademark PRODUCTS INDIA PVT. Compressor Model SHY73MC4-U SHV33YE6UU AWR5538EXC Hermetic motor Compressor Type ROTARY ROTATORY compressor L.R.A. (A) Compressor RLA(A) 10.9 15.2 Compressor Power Input(W) 2085 2335 3200 Overload Protector PUT-IN Internal Inherent Protector...
  • Page 5 Fengyun Series Model GWCN28C1NK3AA GWHN28C1NK3AA COOLING HEATING COOLING HEATING Function Rated Voltage 220-240V~ 230V~ Rated Frequency 50HZ 50HZ Total Capacity (W/Btu/h) 8000 8000 8800 Power Input (W) 2800 2800 2800 Rated Input (W) 4000 4000 3600 Rated Current (A) 17.4 17.4...
  • Page 6 Model of Outdoor Unit GWCN28C1NK3AA/O GWHN28C1NK3AA/O Compressor DAIKIN DAIKIN Manufacturer/trademark Compressor Model JT90G-P8V1N JT90G-P8V1N Compressor Type Hermetic motor compressor Hermetic motor compressor L.R.A. (A) 75.5 75.5 Compressor RLA(A) 13.2 13.2 Compressor Power Input(W) 2950 2950 Overload Protector Internal Inherent Protector Internal Inherent Protector Throttling Method Capillary...
  • Page 7 Fengyun Series Model GWHN24C1NK1BA GWCN24C1ND1AA COOLING HEATING Function COOLING Rated Voltage 220-240V~ 220V~ Rated Frequency 50HZ 60HZ Total Capacity (W/Btu/h) 6800 7300 7000 Power Input (W) 2200 2250 2450 Rated Input (W) 2810 2920 3300 Rated Current (A) 10.6 10.7 23.5...
  • Page 8 GWHN24C1NK1BA/O GWCN24C1ND1AA/O Model of Outdoor Unit Compressor Manufacturer/trademark HIGHLY Compressor Model SHV33YE6UU C-2R170H6S Compressor Type ROTATORY Hermetic motor compressor L.R.A. (A) Compressor RLA(A) 10.9 12.2 Compressor Power Input(W) 2335 1700 Overload Protector Internal Inherent Protector Internal Inherent Protector Throttling Method Capillary Capillary Starting Method...
  • Page 9 Fengyun Series Model GWCN28C1TD1AA GWHN28C1TD1AA Function COOLING COOLING HEATING Rated Voltage 220V~ 220V~ Rated Frequency 60Hz 60Hz Total Capacity (W/Btu/h) 8000W/28000Btu/h 8000W/28000Btu/h 8800W/30000Btu/h Power Input (W) 3400 3400 3300 Rated Input (W) 4050 4050 4050/3800 Rated Current (A) 21.66 21.66 21.66/20.32...
  • Page 10 Model of Outdoor Unit GWCN28C1TD1AA/O GWHN28C1TD1AA/O Compressor Manufacturer/trademark TECUMSEH PRODUCTS INDIA TECUMSEH PRODUCTS INDIA Compressor Model AWZ5532EXN AWZ5532EXN Compressor Type Hermetic motor compressor Hermetic motor compressor L.R.A. (A) Compressor RLA(A) 14.5 14.5 Compressor Power Input(W) 3200 3200 Overload Protector Internal Inherent Protector Internal Inherent Protector Throttling Method Capillary...
  • Page 11 Fengyun Series Model GWHN24C1NK3AB GWHN28C1ND1AA Function COOLING HEATING COOLING HEATING Rated Voltage 220-240V~ 220V~ Rated Frequency 50HZ 60HZ Total Capacity (W/Btu/h) 7000 8000 8800 9500 Power Input (W) 2600 2600 3380 3350 Rated Input (W) 3650 3500 4600 4550 Rated Current (A) 13.8...
  • Page 12 Model of Outdoor Unit GWHN24C1NK3AB/O GWHN28C1ND1AA/O Compressor Manufacturer/trademark SANYO Compressor Model C-3RV322H1AAF SQ034KBA Compressor Type Hermetic motor compressor Hermetic motor compressor L.R.A. (A) Compressor RLA(A) 13.2 Compressor Power Input(W) 2686 3170 Overload Protector Internal Inherent Protector Internal Inherent Protector Throttling Method Capillary Capillary Starting Method...
  • Page 13 Fengyun Series GWHN24C1ND1AA GWCN24C1NK1AA Model COOLING HEATING COOLING HEATING Function 220V~ 220V~ Rated Voltage 60HZ 60HZ Rated Frequency Total Capacity 7000 7600 7100 Power Input 2450 2400 2700 Rated Input 3500 2750 4000 Rated Current 23.5 1100 1100 Air Flow Volume...
  • Page 14 Model of Outdoor Unit GWHN24C1ND1AA/O GWCN24C1NK1AA/O Compressor Model C-2R170H6S LH48VBAC Compressor Type Hermetic motor compressor Hermetic motor compressor L.R.A. (A) Compressor RLA(A) 12.2 12.3 Compressor Power Input(W) 1700 2660 Overload Protector Internal Inherent Protector Internal Inherent Protector Throttling Method Capillary Capillary Starting Method Capacitor...
  • Page 15 Fengyun Series Model GWCN28C1ND1AA GWHN24C1NK3AA Function COOLING HEATING COOLING HEATING Rated Voltage 220V~ 220-240V~ Rated Frequency 60HZ 50HZ Total Capacity (W) 8800(30000btu) 7000 8000 Power Input (W) (High/Normal) 3380 2600 2400 Rated Input (W) (High/Normal) 4600 3400 3100 Rated Current (A) (High/Normal) 14.8...
  • Page 16 Model of Outdoor Unit GWCN28C1ND1AA/O GWHN24C1NK3AA/O Compressor Model SQ034KBA C-3RV322H1AAF Compressor Type Hermetic motor compressor Hermetic motor compressor L.R.A. (A) Compressor RLA(A) 13.2 Compressor Power Input(W) 3170 2686 Overload Protector Internal Inherent Protector Internal Inherent Protector Throttling Method Capillary Capillary Starting Method Capacitor Capacitor...
  • Page 17 Fengyun Series Model GWCN24C1NK3AA GWHN24C1NK1AA Function COOLING HEATING COOLING HEATING Rated Voltage 220-240V~ 220-230V~ Rated Frequency 50HZ 50HZ Total Capacity (W) 7000 7100 8000 Power Input (W) (High/Normal) 2600 2700 2700 Rated Input (W) (High/Normal) 3400 4000 3000 Rated Current (A) (High/Normal) 14.8...
  • Page 18 Model of Outdoor Unit GWCN24C1NK3AA/O GWHN24C1NK1AA/O Compressor Model C-3RV322H1AAF LH48VBAC Compressor Type Hermetic motor compressor Hermetic motor compressor L.R.A. (A) Compressor RLA(A) 13.2 12.3 Compressor Power Input(W) 2686 2660 Overload Protector Internal Inherent Protector Internal Inherent Protector Throttling Method Capillary Capillary Starting Method Capacitor...
  • Page 19 Model KFR-80GW/A22-C Function COOLING HEATING Rated Voltage 220-230V~ Rated Frequency 50HZ Total Capacity (W) 8000 8800 Power Input (W) (High/Normal) 2800 2750 Rated Input (W) (High/Normal) 4010 3600 Rated Current (A) (High/Normal) 20.5 19.5 1250 Air Flow Volume (m /h) (H/M/L) Dehumidifying Volume (l/h) C.O.P / EER (W/W) (High/Normal*) 2.86...
  • Page 20 Model of Outdoor Unit KFR-80W/A22-C Compressor Model ZR36KH-PFJ-522 Compressor Type Hermetic motor compressor L.R.A. (A) Compressor RLA(A) 17.1 Compressor Power Input(W) 2730 Overload Protector Internal Inherent Protector Throttling Method Capillary Starting Method Capacitor Working Temp Range ( ℃ ) -5 ≤ T ≤ 43 Condenser Aluminum fin-copper tube Φ...
  • Page 21: Component Name

    Fengyun Series Component Name Air inlet Electrical box cover Front Panel Manual switch Indoor Unit Body case louver Display window Filter Air outlet Manual switch Remote controller Display window connecting pipe and wire Heating Receiving window Cooling Outdoor Unit Air inlet...
  • Page 22 Indoor Unit Electrical box cover Air inlet Front Panel Manual switch Body case louver Display window Filter Air outlet Manual switch Remote controller connecting pipe Display window and wire Heating Receiving window Cooling Outdoor Unit Air inlet Drainage hose Air outlet grille Air outlet...
  • Page 23 Fengyun Series Overall and Installing Dimension Air inlet grill Right Tube Left Tube-exit Sign Top View -exit Sign Rear View Ceiling Left Right...
  • Page 24 Air inlet grill Right Left Tube-exit Sign Tube Top View -exit Sign Rear View Ceiling Left Right...
  • Page 25 Fengyun Series UNIT:mm Over 600 Over 600 Over 600 Over 600 Bolt Wrench...
  • Page 26: Electrical Diagram

    5 5 5 5 5 Electrical Diagram...
  • Page 27 Fengyun Series...
  • Page 29 Fengyun Series...
  • Page 31 Fengyun Series In case of any change in the Electrical Diagram shown above, please follow the drawing on cabinet.
  • Page 33: Temperature Parameters

    Fengyun Series Controller Function Manual and Operating Instructions 6 6 6 6 6 Remote Controller Function Manual Temperature Parameters Indoor preset temperature (T preset Indoor ambient temperature (T amb. Basic Functions Under each mode, once the compressor start up, it will not be stopped within 6 minutes and will be restart after 3mins later.
  • Page 34: Fan Mode

    Fan mode Under Fan mode, Low Speed Middle SpeedHigh Speed Auto Speed the indoor fan runs at preset speed. The temperature can be set within a range from 16 to 30 . The initial value is 25 Auto mode Under this mode, the system will automatically select its run mode (cooling, fan, heating) with the change of ambient temperature. For protection function, same as under cooling or heating mode.
  • Page 35 Fengyun Series When putting the swing switch to RUN position, the main unit will run as instructed by remote control signal. When putting the swing switch to STOP position, the complete unit will be stopped and will not accept remote control signal.
  • Page 36: Dehumidifying Mode

    Remote Controller Function Manual 6.1.1 Temperature Parameters Indoor preset temperature (T preset Indoor ambient temperature (T amb. 6.1.2 Basic Functions Under any mode, the compressor, once started, will not be stopped within 6 minutes . Once Stopped, the compressor should in no way be restarted unless 3-minute lag. 6.1.2.1 Cooling Mode 6.1.2.1.1 Cooling Conditions and Process When T...
  • Page 37 Fengyun Series 6.1.2.3 Heating Mode 6.1.2.3.1 Heating Conditions and Process When T ≤T +2 , the unit will run under heating mode,in ℃ which case the reversal valve, compressor and outdoor am b. preset fan will be started simultaneously, while the indoor fan will run after 2minutes (max) delay .
  • Page 38 6.1.3.2 AUTO ON AUTO ON function can be set when the unit is at off mode. Upon the time as set , the controller will run under preset mode. The interval of time setting is 0.5h and can be set within 0.5-24h in cycle. 6.1.3.3 AUTO OFF AUTO OFF function can be set when the unit is at on mode.
  • Page 39 Fengyun Series 6.1.4 Protection 6.1.4.1 Antifreeze Protection If it is detected that the system is under antifreeze protection under cooling mode, the compressor and outdoor fan will be stopped, the indoor fan and the swing motor will maintain its original operating status.. When antifreeze protection is released and the compressor has stopped for 3 minutes, the controller will run at the preset mode.
  • Page 40: Disassembly And Assembly Procedures

    Disassembly and Assembly Procedures 7 7 7 7 7 Disassembly Procedures of Indoor Unit Operating Procedures / Photos Disassemble Filter Push the filter inward and then pull it upward to remove it. Twist off screws to remove the cover plate of electric box. (refer to Figure 7-1)...
  • Page 41 Fengyun Series Operating Procedures / Photos Disassemble Front Case Unscrew the three screw cover at the front case, unscrew the six screws, and pull backward the front case to remove it. (refer to Figure 7-4) Screw Figure 7-4 Disassemble Electric Box Cover Unscrew the screw fixing the light plate to remove the light plate.
  • Page 42 Operating Procedures / Photos Disassemble Water Tray Push open the clasp fixing the water tray, and pull the water tray upward to remove the water tray. (refer to Figure 7-7) Water Tray Clasp Figure 7-7 Disassemble Evaporator Use screwdriver to screw off the two screws at the rear pipe clamp to remove the rear pipe clamp.
  • Page 43 Fengyun Series Operation Process / Photoes Disassemble Motor clamp Use a screwdriver to unscrew the two screws fixing the motor clamp and then remove the motor clamp. Unscrew the 3 holding screws on the bearing cover and remove the motor.
  • Page 44 Disassembly Procedures of Outdoor Unit Operating Procedures / Photos Disassemble Front Side Plate Front Side Plate Screw off the four screws around the front side plate to remove the front side plate. (refer to Figure 7-14) Screws Figure 7-14 Disassemble Top Cover Screw off the tapping screws around the top cover, and then pull the top cover upward to remove it.
  • Page 45 Fengyun Series Operating Procedures / Photos Disassemble Cabinet Use screwdriver to screw off the screws around the cabinet to remove the cabinet. (refer to Screw Figure 7-17) Cabinet Figure 7-17 Disassemble Electric Box Use screwdriver to screw off the two screws...
  • Page 46 Operating Procedures / Photos Disassemble Axial Flow Fan Use spanner to remove the nut at the fan to remove the axial flow fan. (refer to Figure 7-20) Axial Flow Fan Figure 7-20 Disassemble Outdoor Motor Motor Screw off the four tapping screws fixing the motor, pull out the motor lead-out cable plug, and Screw Fixing the Motor...
  • Page 47 Fengyun Series Operating Procedures / Photos Disassemble Capillary Unsold the soldering points at the capillary, the valve and the condenser to remove the capillary. Capillary Pay attention not to allow the soldering slag to block the capillary. (refer to Figure 7-23)...
  • Page 48 Exploded View and Components and Parts List Exploded View of Components and Parts of Indoor Unit...
  • Page 49 Fengyun Series Components and Parts List of Indoor Unit Part Code Description GWCN24C1ND1BA/I GWCN24C1NK1BA/I Wall-Mounting Frame 01252398 01252398 Rear Case 22202040 22202040 Fan Bearing 76512203 76512203 Screw Cover 242520053 242520053 Swing Louver 10512030 10512030 Swing Link 10582040 10582040 Water Tray...
  • Page 50 Part Code Description GWHN24C1NK1BA/I GWCN28C1TK1AA/I Wall-Mounting Frame 01252398 01252398 Rear Case 22202040 22202040 Fan Bearing 76512203 76512203 Screw Cover 242520053 242520053 Swing Louver 10512030 10512030 Swing Link 10582040 10582040 Water Tray 20182043 20182043 Guide Louver ( up ) 10512062 10512062 Guide Louver (...
  • Page 51 Fengyun Series Exploded View of Components and Parts of Indoor Unit...
  • Page 52 Components and Parts List of Indoor Unit Part Code Description GWHN28C1NK3AA/I GWCN28C1NK3AA/I GWHN24C1NK3AA/I Wall-Mounting Frame 01252398 01252398 01252398 Rear Case 22202040 22202040 22202040 Fan Bearing 76512203 76512203 76512203 Screw Cover 242520053 242520053 242520053 Swing Louver 10512030 10512030 10512030 Swing Link 10582040 10582040 10582040...
  • Page 53 Fengyun Series Part Code Description GWCN28C1TD1AA/I GWHN28C1TD1AA/I GWHN24C1NK3AB/I Wall-Mounting Frame 01252398 01252398 01252398 Rear Case 22202040 22202040 22202040 Fan Bearing 76512203 76512203 76512203 Screw Cover 242520053 242520053 242520053 Swing Louver 10512030 10512030 10512030 Swing Link 10582040 10582040 10582040 Water Tray...
  • Page 54 Part Code Description GWCN24C1NK3AA/I Wall-Mounting Frame 01252398 Rear Case 22202040 Fan Bearing 76512203 Screw Cover 242520053 Swing Louver 10512030 Swing Link 10582040 Water Tray 20182043 Guide Louver(up) 10512062 Guide Louver(down) 10512063 Cross Flow Fan 10352420 Evaporator Assy 010041299 Drainage Pipe 0523001401 Evaporator Support(left) 24212041...
  • Page 55 Fengyun Series Exploded View of Components and Parts of Indoor Unit...
  • Page 56 Components and Parts List of Indoor Unit Part Code Description GWHN24C1ND1AA/I GWCN24C1NK1AA/I GWCN24C1ND1AA/I Wall-Mounting Frame 01252398 01252398 01252398 Rear Case 22202040 22202040 22202040 Fan Bearing 76512203 76512203 76512203 Screw Cover 242520053 242520053 242520053 Swing Louver 10512030 10512030 10512030 Swing Link 10582040 10582040 10582040...
  • Page 57 Fengyun Series Part Code Description GWCN28C1ND1AA/I GWHN28C1ND1AA/I GWHN24C1NK1AA/I Wall-Mounting Frame 01252398 01252398 01252398 Rear Case 22202040 22202040 22202040 Fan Bearing 76512203 76512203 76512203 Screw Cover 242520053 242520053 242520053 Swing Louver 10512030 10512030 10512030 Swing Link 10582040 10582040 10582040 Water Tray...
  • Page 58 Part Code Description KFR-80G/A22-C Wall-Mounting Frame 01252398 Rear Case 22202040 Fan Bearing 76512203 Screw Cover 242520053 Swing Louver 10512030 Swing Link 10582040 Water Tray 20182043 Guide Louver ( up ) 10512062 Guide Louver ( down ) 10512063 Cross Flow Fan 10352420 Cross Flow Fan 10352420...
  • Page 59 Exploded View of Components and Parts of Outdoor Unit...
  • Page 60 Fengyun Series Components and Parts List of Oudoor Unit Part Code Description GWCN24C1ND1BA/O GWCN24C1NK1BA/O GWHN24C1NK1BA/I Front Grill 22415001 22265251 22265251 Front Plate 01433031 01435254 01435254 Axial Flow Fan 10335257 10335253 10335253 Motor LW80C 15013062 15013106 15013106 Motor Support 01703027 01705253...
  • Page 61 Part Code Description GWCN24C1ND1AA/O GWHN24C1ND1AA/O GWCN24C1NK1AA/O Front Grill 22265251 22265251 22265251 Front Plate 01435401 01435251 01435254 Axial Flow Fan 10335254 10335254 10335253 Motor FW60L 15013063 15013063 15013106 Motor Support 01705253 01705253 01705253 Condenser Assy 011036793 011036792 011036795 Temp Sensor Support 24215101 24215101 24215101...
  • Page 62 Fengyun Series Part Code Description GWHN28C1ND1AA/O GWCN28C1ND1AA/O GWHN24C1NK1AA/O Front Grill 22265401 22265401 22265251 Front Plate 01435401 01435402 01435251 Axial Flow Fan 10335401 10335401 10335254 Motor LW92F 150154012 150154012 15013106 Motor Support 01705401 01705403 01705253 Condenser Assy 011032345 01103830 011036794 Temp Sensor Support...
  • Page 63 Part Code Description KFR-80W/A22-C Front Grill 22265401 Front Plate 01435401 Axial Flow Fan 10335401 Motor LW92B 15015401 Motor Support 01705401 Condenser Assy 011032341 Temp Sensor Support 24215101 Ambient Sensor 390002064 Top Cover 01255402 Rear Grill 01475401 upper Electric box cover 01413075 Electric Plate 014033591...
  • Page 64 Exploded View of Components and Parts of Outdoor Unit...
  • Page 65 Fengyun Series Components and Parts List of Oudoor Unit Part Code Description GWCN28C1TK1AA/O GWCN28C1NK3AA/O GWHN28C1NK3AA/O Front Grill 22265401 22265401 22265401 Front Plate 01435402 01435402 01435402 Axial Flow Fan 10335253 10335401 10335401 Motor LW80C 15015401 15015401 15015401 Motor Support 01705401 01705401...
  • Page 66 Part Code Description GWCN28C1TD1AA/O GWHN28C1TD1AA/O Front Grill 22265401 22265401 Front Plate 01435402 01435402 Axial Flow Fan 10335253 10335253 Motor LW92P 15015452 15015452 Motor Support 01705401 01705401 Condenser Assy 011032341 011032341 Temp Sensor Support 24215101 24215101 Ambient Sensor 390002064 390002064 Top Cover 01255402 01255402 Rear Grill...
  • Page 67 Fengyun Series Exploded View of Components and Parts of Outdoor Unit...
  • Page 68 Components and Parts List of Oudoor Unit Part Code Description GWHN24C1NK3AB/O Front Grill 01473001 Front Plate 01433011 Axial Flow Fan 10335253 Motor LW80C 15013106 Motor Support 01705253 Condenser Assy 011036796 Temp Sensor Support 24215101 Ambient Sensor 390002065 Top Cover 01255262 Rear Grill 01475252 upper Electric box cover...
  • Page 69 Fengyun Series Exploded View of Components and Parts of Outdoor Unit...
  • Page 70 Components and Parts List of Oudoor Unit Part Code Description GWHN24C1NK3AA/O GWCN24C1NK3AA/O Front Grill 22265251 22265251 Front Plate 01433011 01433011 Axial Flow Fan 10335253 10335253 Motor LW80C 15013106 15013106 Motor Support 01705253 01705253 Condenser Assy 011036796 011036797 Temp Sensor Support 24215101 24215101 Ambient Sensor...
  • Page 71: Troubleshooting

    Fengyun Series 9 9 9 9 9 Trouble-Shooting When set circuit breaker Check insulation resistance for as “ ON ” , it trips grounding; Confirm immediately air-conditioning unit electrical leakage short-circuited Trip of circuit breaker or burn-out of fuse Failure of air-conditioning unit...
  • Page 72 Set temperature is not Adjust the set temperature appropriate Check if the cooling (heating) Check the forecasted cooling (heating) load load is appropriate Check leakage, carry out Leakage of refrigerant or vacuum-pumping after repairing insufficient refrigerant leakage and charge refrigerant according to requirements Leakage between internal high pressure and low...
  • Page 73 Fengyun Series Indoor fan motor burned out or there Replace fan motor or components is wire breakage or failure of with failure overheating protector The internal overheating protector When air supply frequently breaks as overheating is Replace fan motor mode...
  • Page 74: Water Leakage

    Fan of indoor unit touches other Adjust fan position positions Remove foreign articles Foreign articles inside the indoor unit Adjust support foot Vibration of compressor is violent compressor, tighten loose bolts Pipes of outdoor unit bump together Separate bumping pipes Abnormal sound and vibration 1.

Table of Contents