Install indoor unit
Refer fig. 11-5 and 11-6 for piping type of indoor unit. When routing the piping and wiring from left or right side of
indoor unit, cut off tailings left from pipe from base of main unit in necessary (as shown in fig.11-7).
Go through wire hole when only power wire is led;
Cut off tailing 1 when connect pipe and wire are led;
After wrapping pipe and wire, pull them though the piping hole (As shown in fig.11-8).
Hang the mounting slots that behind indoor unit onto the upper tabs of the rear panel and check if it is firm enough
Ensure that the install height of indoor unit is 2.3 m or more from floor.
Fig. 11-7
Tailing 2
Signal control wire
Tailing 1
(Only for heat pump unit)
Hole
Bird Single-Split Type
Power connect wire
Drainage hose
Connect pipe
Wrapping strap
Fig. 11-8