WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
OBSERVED PROBLEM
Gas odor even when gas control valve is off
Gas odor during combustion
Glass soots
Dark residue on inside of fireplace
Purchase these accessories from your local dealer. If they can not supply these accessories call IHP at 1-800-655-2008 for information. You
can also write to the address listed on the back page of this manual.
SMOOTH GLASS PEBBLES (6 LBS)
F1101 - GP43SO - Speckled Orange
F1097 - GP43A - Amber
F1099 - GP43G - Green
F1098 - GP43B - Blue
PROPANE/NATURAL GAS CONVERSION KIT
IMPORTANT: NOT to be used for High Altitude
F1980 - PCDE-43LDV - Propane/LP Gas Conversion Kit
F1981 - NCDE-43LDV - Natural Gas Conversion Kit
126718-01C
TROUBLESHOOTING Continued
POSSIBLE CAUSE
1. Gas leak. See Warning statement at top
of page
2. Control valve defective
1. Foreign matter between control valve and
burner
2. Gas leak. See Warning statement at top
of page
1. Debris around burner air mixer
2. Improper vent configuration
1. Air holes at burner inlet blocked
2. Burner flame holes blocked
3. Improper venting or excessive blockage

ACCESSORIES

DECORATIVE FACE TRIM
F1036 - DFT43B - Black
F1037 - DFT43AS - Aged Silver
F1038 - DFT43AC - Aged Cooper
SEE-THRU DOOR KIT
F2312 - LDSTIB
OUTDOOR DOOR KIT
F2313 - LDSTOB
OUTDOOR BARRIER KIT
F2253
Superiorfireplaces.US.com
REMEDY
1. Locate and correct all leaks (see Checking
Gas Connections, page 22)
2. Replace control valve
1. Take apart gas tubing and remove foreign
matter
2. Locate and correct all leaks (see Checking
Gas Connections, page 22)
1. Inspect opening at base of burner to see
that it is NOT packed with any type of
material
2. Check vent configuration specification
(see Venting Installation, page 11)
1. Clean out air holes at burner inlets. Peri-
odically repeat as needed
2. Remove blockage
3. Have vent system inspected, including
termination cap. Remove any restrictions
or obstruction
35