VENTING INSTALLATION Continued
PARTS LIST FOR VENTING KITS AND COMPONENTS
Table 3: Listed Components
Catalog
Model
Number
F1797 *
SV4.5HTKCT
F1798 *
SV4.5HTKCT20
H1968
SV4.5HT-2
H2152
SV4.5CGV-1
H8914
SV4.5TK90HT2
Vent Sections (Rigid)
77L70
SV4.5L6
77L71
SV4.5L12
77L72
SV4.5L24
77L73
SV4.5L36
77L74
SV4.5L48
77L75
SV4.5LA
The following flashing comes packaged with a storm collar
77L78
SV4.5F
77L79
SV4.5FA
77L80
SV4.5FB
77L81
SV4.5SC6
H6183
SV4.5HF5
H2246
SV4.5HF-10
H2247
SV4.5VF-10
96K92
SV4.5SP
77L76
SV4.5E45
77L77
SV4.5E90
20
Description
Rigid, Horizontal, Compact Ter-
mination with Firestop/Spacer
(H2246), Adaptor (74L61)
(see 750204M)
Rigid, Horizontal Compact
Termination, 20" with Shield
and Firestop (see 750247M and
750204M)
Horizontal Square Termination
with Firestop/Spacer (H2246),
and Adaptor (74L61)
Vertical Termination Cap, High
Wind
Horizontal Termination Kit HT-2
with 90° elbow
6" (152 mm)
12" (305 mm)
24" (610 mm)
36" (914 mm)
48" (1219 mm)
Telescopic Length Slip Section
(2–7 1/2" rigid)
Flat Roof Flashing
1/12 to 7/12 Adjustable
Flashing
7/12 to 12/12 Adjustable
Flashing
Storm Collar (6 pack)
Firestop Spacer, 5", rigid
Firestop/Spacer-Horizontal, rigid
(3-1-1 spacing), 10 Pack
Firestop/Spacer-Vertical, rigid
(1-1-1 spacing), 10 Pack
Support Plate
Elbows
45° Elbow
90° Elbow
Superiorfireplaces.US.com
FIREPLACE INSTALLATION
CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If you have
conflicting gas types, do not install fireplace. See retailer where you
purchased the fireplace for proper fireplace according to your gas type.
INSTALLING GAS PIPING TO FIREPLACE LOCATION
WARNING: A qualified service person must con-
nect fireplace to gas supply. Follow all local codes.
CAUTION: For propane/LP units, never connect
fireplace directly to the propane/LP supply. This
heater requires an external regulator (not supplied).
Install the external regulator between the fireplace
and propane/LP supply.
WARNING: For natural gas, never connect fireplace
to private (non-utility) gas wells. This gas is commonly
known as wellhead gas.
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connector (if allowed by local
codes)
* An equipment shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the equipment shutoff
valve from your retailer.
For propane/LP connection only, the installer must supply an external
regulator. The external regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to between 11" and 14" of
w.c. pressure. If you do not reduce incoming gas pressure, fireplace
regulator damage could occur. Install external regulator with the vent
pointing down as shown in Figure 25, page 21. Pointing the vent down
protects it from freezing rain or sleet.
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of 1/2" diam-
eter or greater to allow proper gas volume to fireplace.
If pipe is too small, undue loss of volume will occur.
Installation must include an equipment shutoff valve, union and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from fireplace (see Figure 26).
IMPORTANT: Install main gas valve (equipment shutoff valve) in an
accessible location. The main gas valve is for turning on or shutting
off the gas to the appliance.