Superior DRL4543TEN Installation And Operation Instructions Manual page 31

Direct-vent linear gas fireplace
Table of Contents

Advertisement

ON
OFF
Cont.
ROOM
Pilot
°
SET
S M T W T F S
P1
PROGRAM
:
AM
P2
PM
A
B
AUX
MODE/SET
MODE/SET
DOWN
Button
Button
Figure 49 - Touch Screen Settings
Day and Time Display
The current day of week and time of day will be continuously dis-
played in the TIME/PROG Zone (except during Setup operations).
The day of week will be displayed as one of the following: S, M,
T, W, T, F, S
The time of day will be in 12-hour AM, 12-hour PM format.
Midnight will be displayed as 12:00am.
Day/Time Setup:
Press and hold the MODE Zone or the MODE/SET Button
for 5 seconds to enter Day/Time Setup.
Press the UP or DOWN Buttons to adjust the day of week
(press the MODE/SET Button or wait for 15 seconds for ad-
justment to be accepted, then enter hour of day adjustment).
Press the UP or DOWN Buttons to adjust the hour of the
day. The time will advance in 1-hour increments; AM and
PM will change when the hour advances to 12:00 midnight
and 12:00 noon respectively (press the MODE/SET Button
or wait for 15 seconds for adjustment to be accepted, then
enter minute of hour adjustment).
Press the UP or DOWN Buttons to adjust the minute of the
hour. The time will advance in 1-minute increments (press
the MODE/SET Button or wait for 15 seconds and the
transmitter will exit Day/Time Setup and return to normal
operation).
LCD Displays – when in Day/Time Setup:
MODE Zone: Blank
ROOM TEMP Zone: Blank
SET TEMP Zone: Blank
LIGHT Zone: Blank
FAN Zone: Blank
TIME/PROG Zone: Day of Week, or Time of Day will Flash
AUX Zone: Blank
FLAME Zone: Blank
126718-01C
REMOTE CONTROL OPERATION Continued
MODE Zone
ROOM TEMP
Zone
°
SET TEMP Zone
(Unused)
USB
P2
TIME/PROG.
P2
Zone
LIGHT Zone
FLAME Zone
AUX Zone
(Unused)
FAN Zone
(Unused)
UP Button
Superiorfireplaces.US.com
Temperatures may be displayed in degrees F (factory default)
or degrees C. Press the up and down buttons simultaneously
to change between degrees F. and C.
MODES OF OPERATION
Operation modes:
MANUAL OFF
MANUAL ON
The modes may be cycled in the order above by pressing the MODE
Zone or the MODE/SET Button.
MANUAL OFF MODE
Transmits flame OFF command.
LCD Displays:
MODE Zone: OFF is displaye
ROOM TEMP Zone: Measured temperature is displayed
SET TEMP Zone: Blank
LIGHT Zone: LIGHT and light setting level is displayed
FAN Zone: Blank
TIME/PROG Zone: Current day indicator and current time
is displayed
AUX Zone: Blank (AUX function is omitted on this control)
FLAME Zone: Blank
MANUAL ON MODE:
Transmits flame ON command
LCD Displays:
MODE Zone: ON is displayed
ROOM TEMP Zone: Measured temperature is displayed
SET TEMP Zone: Blank
LIGHT Zone: LIGHT and light setting level is displayed
FAN Zone: FAN and fan setting level is unused
TIME/PROG Zone: Current day indicator and current time
is displayed
AUX Zone: Blank (AUX function is omitted on this control)
FLAME Zone: A&B Flame Icons and flame setting level
numbers are displayed
FLAME - A (OR MAIN) ADJUSTMENT
Transmits a flame height setting command to the control module
to adjust the Flame-A height.
Available settings are 1-7 with a factory default of 7. If the Flame-
A setting is changed during operation (either manually or auto-
matically), the control will remember and use the adjusted setting
on subsequent manual ON cycles (Flame-A setting memory).
While in MANUAL ON, or PROGRAM ON modes, press the FLAME
Zone to enter Flame-A Adjustment, then press the UP or DOWN
buttons to raise and lower the flame; press the MODE/SET Button
or wait for 15 seconds to accept the new setting.
LCD Display: When setting the Flame-A height, the Flame-A
icon, and Flame-A setting number will flash in the FLAME Zone.
31